| 039187124H | May 4, 2026 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Jul 8, 2026 | Defaulted (did not respond) | $1,280.00 |
| 871114 | May 4, 2026 | CLASS 2: 1) EMERGENCY PHONE INOPERATIVE AS REQUIRED BY ASME A17.1/CSA B44 AND 1 RCNY 3610-01. REMEDY: PROVIDE CLEAR 2-WAY COMMUNICATION. 2) MAINTENANCE LOG NOT UP TO DATE AS REQUIRED BY ASME A17.1 8.6.1.4. REME | Jul 8, 2026 | Defaulted (did not respond) | $3,125.00 |
| 1845739 | May 4, 2026 | CLASS 1 CEASE USE: 1)DOOR ZONE RESTRICTOR INOPERATIVE. 2)CAR STOPS OFF LEVEL OVER 4" ON MULTIPLE FLOORS, IN VIOLATION OF ASME A17.1 2.12.5 AND 2.14.2.3. REMEDY: REPAIR AND RESTORE PROPER LEVELING AND DOOR OPERA | Jul 8, 2026 | Defaulted (did not respond) | $6,250.00 |
| 039187125J | May 4, 2026 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Jul 8, 2026 | Defaulted (did not respond) | $655.00 |
| 1722924 | Oct 28, 2025 | FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF CELLAR LEVEL, OBSERVED CRACKED/SPALLED CONCRETE AT SLABS, BEAMS AND FOUNDAT | Apr 15, 2026 | Found in violation | — |
| 035717853H | Oct 28, 2025 | FAILURE TO MAINTAIN - PARKING STRUCTURE | Apr 15, 2026 | Found in violation | — |
| 1495015 | Oct 1, 2024 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PERIODIC INSPECTION OF A PARKING STRUCTURE(PIPS) REPORT DOCUMENTING THE CONDITIONS OF PSID#B000 | Nov 17, 2025 | Defaulted (did not respond) | — |
| 037031259L | Oct 1, 2024 | MISCELLANEOUS VIOLATIONS | Nov 17, 2025 | Defaulted (did not respond) | — |
| 039088119J | Jun 8, 2023 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Aug 16, 2023 | Found in violation | — |
| 1660680 | Jun 8, 2023 | CLASS 1: DOOR LOCK MONITORING (DLM) INOPERATIVE. TROUBLE SHOOT WIRES & REPAIR. CLASS 2: PHONE INOEPRATIVE REPAIR & PROGRAM TO 24 HR EMERGENCY OPERATOR. CAR BUTTON STATION NOT TAGGED WITH DEVICE #. PROVIDE NYC I | Aug 16, 2023 | Found in violation | — |
| 1660675 | Jun 8, 2023 | CLASS 2: PHONE INOPERATIVE REPAIR & PROGRAM TO 24 HR EMERGENCY OPERATOR. CAR BUTTON STATION NOT TAGGED WITH DEVICE #. PROVIDE NYC ID TAGS. CAR FLOOR NOT LEVEL TO LANDING SILL POSING SEVERE TRIPPING HAZZARD. ADJ | Aug 16, 2023 | Found in violation | — |
| 039088118H | Jun 8, 2023 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Aug 16, 2023 | Found in violation | — |
| 1615984 | Mar 28, 2023 | INOPERATIVE PHONE. MISALIGNED MIRROR. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. CLEAN GOV ROPE FOR PROPER INSPECTION. MISSING MACHINE ROOM VENTILATION. SHORTEN GOV ROPE. WORN BRAKE SLEEVE. SECUR | Aug 2, 2023 | Found in violation | — |
| 1615936 | Mar 28, 2023 | INOPERATIVE PHONE. MISALIGNED MIRROR. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. CLEAN GOV ROPE FOR PROPER INSPECTION. MISSING MACHINE ROOM VENTILATION.. UNREADABLE CONTROLLER FUSES. | Aug 2, 2023 | Found in violation | — |
| 039082467Z | Mar 28, 2023 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Aug 2, 2023 | Found in violation | $625.00 |
| 039082466R | Mar 28, 2023 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Aug 2, 2023 | Found in violation | $625.00 |
| 039066656H | Jul 25, 2022 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Dec 7, 2022 | Defaulted (did not respond) | $6,250.00 |
| 1404858 | Jul 25, 2022 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). DLM WAS INSTALLED AS MANDATED BY CODE A17.1 APPENDIX K3 SECTION 3.10.12 OF THE 2014 NYCBC. BUT NOT IN COMPLIANCE WITH THE CODE FIREMAN SERVICE MISSIN | Dec 7, 2022 | Defaulted (did not respond) | $6,250.00 |
| 039029689L | Oct 1, 2020 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Feb 3, 2021 | Found in violation | $1,250.00 |
| 1613440 | Oct 1, 2020 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM AN | Feb 3, 2021 | Found in violation | — |
| 929151 | Jul 29, 2020 | CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 2 ITEMS: ADJUST 1ST FLOOR HOISTWAY DOOR ACCESS HOLE. CLEAN TAIL ROPE FOR PROPER INSPECTION. CLEAN OIL FROM GOV ROPE FOR PROPER INSPECTION. REPLACE HOISTWA | Dec 2, 2020 | Defaulted (did not respond) | — |
| 1145452 | Jul 29, 2020 | CLASS ONE ITEM: DLM MISSING AS NOW REQUIRED BY CODE. CLASS 2 ITEMS: REPLACE WORN HOISTWAY DOOR GIBS WHERE NEEDED. CLEAN PIT. CLEAN TAIL ROPE FOR PROPER INSPECTION. CLEAN OIL FROM GOV ROPE FOR PROPER INSPECTION. | Dec 2, 2020 | Defaulted (did not respond) | $6,250.00 |
| 039026096M | Jul 29, 2020 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Dec 2, 2020 | Defaulted (did not respond) | — |
| 039026097Y | Jul 29, 2020 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Dec 2, 2020 | Defaulted (did not respond) | $6,250.00 |
| 039020921X | Apr 10, 2020 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Aug 2, 2021 | Found in violation | — |
| 976893 | Apr 10, 2020 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM A | Aug 2, 2021 | Found in violation | — |
| 037013505Z | Oct 15, 2018 | FAIL SUBMIT REQUIRED REPORT OF CRIT EXAM DOCUMENTING EXTERIOR WALL | Sep 30, 2019 | Found in violation | — |
| 1447008 | Oct 15, 2018 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#810040. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT | Sep 30, 2019 | Found in violation | — |
| 038263683J | Jun 13, 2018 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Aug 13, 2018 | SETTL IN-VIO | — |
| 1401543 | Jun 13, 2018 | 99M5,98M5,56Y2,56Y13,5E1,67L10. 99M5-CURRENT ONE YEAR TEST TAG MISS ING PERFORM AND FILE TEST; 98M5-CURRENT FIVE YEAR TEST TAG MISSING PERFORM AND FILE TEST. 56Y2-HOIST MACHINE OIL LEAK CLEAN; 56Y13-HOIST | Aug 13, 2018 | Resolved | — |
| 1270808 | Dec 28, 2017 | 5-E-1;16-H-11;29-J-1;60-L-10;57-M-7;68-M-7:5-E-1-CAR DOOR RUBBING ADJUST.10-H-11-CAR DOOR GIBS WORN REPLACE.16-E-1-HOISTING DOOR RUBBING ADJUST.29-J-1-DOOR OPERATOR MISALIGNED ADJUST.60-L-10-MACHINE ROOM LIGHT | Feb 26, 2018 | Found in violation | — |
| 038257179J | Aug 7, 2017 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Sep 25, 2017 | Found in violation | — |
| 1401480 | Aug 7, 2017 | CU5M7,CU59A6; 40I10. 40I10- REPAIR WINDOW;CEASE USE ITEMS:BRAKE ADJUSTMENT BOLT IS LOOSE LEFT SIDE; 5M7-PROVIDE DOOR ZONE RESTRICTOR (SAFETY DEVICE) AND NOTIFY NYCDOB BY CALLING 212-393-2520 AND EMAIL EIR@BUI | Sep 25, 2017 | Found in violation | — |
| 035253866Y | May 15, 2017 | MISCELLANEOUS VIOLATIONS | Sep 18, 2017 | Found in violation | — |
| 1379489 | May 15, 2017 | 1RCNY-MISC/OWNER FAILED TO REPAIR BUILDING EXTERIOR FACADE WEST ELEVATON EXPO#1 CRACKS/SPALLING DETERIORATED BRICKS MORTAR SILL AT VARIORS CALCONY MASONRY WALL AT VARIOUS LOCATION/FLOORS WITH IN THE TIME FRAME | Sep 18, 2017 | Found in violation | — |
| 036011251M | Jan 7, 2010 | FAIL SUBMIT REQUIRED REPORT OF CRIT EXAM DOCUMENTING EXTERIOR WALL | May 3, 2010 | Found in violation | — |
| 435425 | Jan 7, 2010 | FAIL TO FILE AN ACCEPTABLE 6TH-ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DOB RULES & REGULATIONS.REMEDY:FIL | May 3, 2010 | Found in violation | — |
| 809712 | Mar 18, 2009 | 43L10 100L10 59L10 100 MOTOR ROOM STEPS PLATFORM UNSECURED 59 BRAKE TENSION EXCESSIVE CAR ROCKING BACK & FORTH AFTER HARD STOP BY BRAKE | May 11, 2009 | Settled by stipulation | — |
| 038201726R | Mar 18, 2009 | FAIL MAINTAIN BLDG IN COMPLIANT MANNER: SERVICE EQUIPMENT | May 11, 2009 | Settled by stipulation | — |
| 867367 | Feb 6, 2009 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPERTENANCES AS REQUIRED BY ARTICLE 28.302 AND THE DOB RULES & REGULATIONS | Aug 16, 2010 | Found in violation | — |
| 036008481K | Feb 6, 2009 | FAIL SUBMIT REQUIRED REPORT OF CRIT EXAM DOCUMENTING EXTERIOR WALL | Aug 16, 2010 | Found in violation | — |
| 622802 | Jan 11, 2008 | 40T07,58M07,58H11,85M07,86M07 58M-BRAKE CLIPS. 58H COPPER BRAKE COIL CORE. | Mar 3, 2008 | Found in violation | — |
| 038179793Z | Jan 11, 2008 | FAILURE TO MAINTAIN ELEVATOR | Mar 3, 2008 | Found in violation | — |
| 172925 | Jul 20, 1998 | 01X,38X,46B,15B,16M,28B,18B, 46B. PROVIDE PROPER RANBY BETWEEN CWT AND BUFFER. 15B. HOIST WAY DOOR HAVE TO BE SEAL CLOSING; 16M. PROVIDE SECOND GIB > FOR 4 FL HOIST DOOR. | Aug 31, 1998 | Found in violation | — |