| 039516987H | May 23, 2023 | FAIL TO NOTIFY DOB PRIOR TO INSTALLATION REMOVAL OF SUSPENDED SCAFFOLD | Sep 26, 2023 | Admitted the violation | — |
| 1666906 | May 23, 2023 | DURING INSPECTION UPON REQUEST TO SEE THE FOLLOWING DOCUMENTS TO BE KEPT ON SITE NONE WERE PROVIDED: NO LOAD IMPOSED LETTER FOR SCAFFOLD INSTALLATION ON TOP OF SIDEWALK SHED EXPO 1, NO APPROVED DESIGN DRAWINGS | Aug 29, 2023 | Admitted the violation | — |
| 039516984M | May 23, 2023 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33 | Aug 29, 2023 | Admitted the violation | — |
| 880494 | May 23, 2023 | AT THE TIME OF MY INSPECTION OF A ACTIVE 7 STORY NB I OBSERVED C HOOK SUSPENDED SCAFFOLD IN USE AND INSTALLED AT EXPOS 2 & 4. UPON REVIEW OF DOB RECORDS NO NOTIFICATION WAS GIVEN PRIOR TO USE. AS PER CODE NOTIF | Sep 26, 2023 | Admitted the violation | — |
| 035670875N | Mar 21, 2023 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS | Sep 26, 2023 | Admitted the violation | — |
| 1586486 | Mar 21, 2023 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING NOT PURSUANT TO SUBSECTION.AS NOTED:AT TIME OF INSPECTION AT ACTIVE JOBSITE OF PROPOSED 7 STORY BUILDING OBSERVED AT FL #1 GRADE LEVEL AT EXP #1 #2 #3 AND CENTER FOUND | Sep 26, 2023 | Admitted the violation | — |
| 035670219P | Feb 14, 2023 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT | Nov 21, 2023 | Defaulted (did not respond) | — |
| 1812971 | Feb 14, 2023 | TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-CONSTRUCTION PLYWOOD FENCE PERMIT EXPIRED.AS NOTED:AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE.7 STORY NEW BUILDING SUPER STRUCTURAL COMPLED TO BULKHEAD.OBSERVED | Nov 21, 2023 | Defaulted (did not respond) | — |
| 1597859 | Feb 8, 2023 | AT TIME OF INSPECTION ON A 7 STORY NB CLOSED AND INACTIVE SITE, NO ACCESS TO VERIFY COMPLIANCE WITH THE CLASS 1 VIOLATION #39509628K. IN ADDITION THE RESPONDENT FAILED TO COMPLY WITH THE COMMISSIONER'S ORDER TO | May 16, 2023 | Admitted the violation | — |
| 039512844M | Feb 8, 2023 | FAIL TO COMPLY W COMMISSIONER ORDER TO FILE CERT OF CORRECTION W DOB | May 16, 2023 | Admitted the violation | — |
| 039512278R | Jan 28, 2023 | WORK AFTER HOURS W O VARIANCE PERMIT CONTRARY TO 28-105.12.5 | Apr 11, 2023 | Admitted the violation | — |
| 1651565 | Jan 28, 2023 | AT THE TIME OF MY INSPECTION I OBSERVED WORKERS TAKING IN A DELIVERY OF LARGE WINDOW FRAMES THAT HAD JUST BEEN DROPPED OFF AT EXPOS 1 AND A 2ND DELIVERY TRUCK IN FRONT. I ALSO OBSERVED NEWLY PREFORMED CEMENT WO | Apr 11, 2023 | Admitted the violation | — |
| 104952 | Jan 28, 2023 | AT THE TIME OF MY INSPECTION OF A 7 STORY NB CONSTRUCTION SITE I OBSERVED PIPE SCAFFOLD APPROX. 60 FEET IN HEIGHT INSTALLED AT EXPOS 3. UPON REQUEST TO SEE DOB APPROVED DESIGN DRAWINGS FOR THE PIPE SCAFFOLD IN | Apr 11, 2023 | Found in violation | — |
| 039512284N | Jan 28, 2023 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33 | Apr 11, 2023 | Found in violation | — |
| 1071617 | Dec 21, 2022 | AT THE TIME OF MY INSPECTION OF A NON-ACTIVE 7 STORY NB I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 THAT DID NOT EXTEND 5' OVER THE ADJOINING PROPERTY WALKWAY AT EXPOS 2 AS PER CODE. AFTER SPEAKING TO CP OF | Nov 21, 2023 | Admitted the violation | — |
| 039510650P | Dec 21, 2022 | PEDESTRAIN PROTECTION DOES NOT MEET CODE SPECIFICATIONS | Nov 21, 2023 | Admitted the violation | — |
| 039509628K | Nov 29, 2022 | FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES - NO HANDRAILS | May 23, 2023 | Found in violation | — |
| 039509634R | Nov 29, 2022 | MISCELLANEOUS VIOLATIONS | May 16, 2023 | Admitted the violation | — |
| 1643474 | Nov 29, 2022 | AT THE TIME OF INSPECTION ON PROPOSED 7 STORY NB ACTIVE JOBSITE, I OBSERVED IN PLACE AT EXP#-4 ADJOINING BUILDING (30-55) ROOF WITH INADEQUATE ROOF PROTECTION- MISSING PLANKS &, 2'' THICK INSULATION AND NOT AS | May 16, 2023 | Admitted the violation | — |
| 871484 | Nov 29, 2022 | AT TIME OF INSPECTION ON PROPOSED 7 STORY NB ACTIVE JOBSITE, I OBSERVED IN MULTIPLE PLACES OF STAIRWAYS BETWEEN FL LEVELS MISSING HANDRAILS. THIS CONDITIONS AT JOBSITE IS DANGEROUS & POSES FALLING HAZARDS FOR A | May 23, 2023 | Found in violation | — |
| 039507237Y | Oct 6, 2022 | PERMIT HOLDER FAIL TO PROVIDE ACCESS AND OR EXPOSE WORK ON ACTIVE SITE | Apr 25, 2023 | Admitted the violation | — |
| 1583024 | Oct 6, 2022 | OBSERVED JOB SITE DOOR IS CLOSED, UPON GET ACCESS FROM SITE NEXT DOOR, OBSERVED MULTIPLE WORKERS ON SITE, UPON REQUEST FROM THEM TO OPEN THE DOOR AND PROVIDE ACCESS ALL WORKERS WENT INSIDE AND HIDE AND NEVER CA | Apr 25, 2023 | Admitted the violation | — |
| 1597272 | Jun 16, 2022 | SITE NOT ADHERE TO SITE SAFETY PLAN 28-105.12.8. ON ACTIVE 7 STORY NB SITE 4TH FL STRUCTURE PHASE PER PROVIDED SITE SAFETY PLAN I DISCOVER SITE DOES NOT ADHERE TO PLAN. 1. MISSING 8 FEET HIGH FENCE ON 2ND FL RE | Oct 18, 2022 | Found in violation | — |
| 1675155 | Jun 16, 2022 | SIDEWALK SHED AREA TO BE PROTECTED NOT TO CODE BC 3307.6.3. ON 7 STORY NB SITE IN STRUCTURE PHASE UP TO 4TH FL WORKING DECK OBSERVE SIDEWALK SHED MISSING 5FT ADDITIONAL DECK TO EXPOSURE# 4 BC 3307.6.3 NOR CONFO | Jan 24, 2023 | Found in violation | — |
| 1597159 | Jun 16, 2022 | WORK OF STORAGE ZONE BC 3307.4.7. ON NB 7 STORY SITE OBSERVE DEBRIS CONTAINER AT FRONT OF SITE ON ROADWAY MISSING BARRIERS ADJACENT TO THE SITES SIDEWALK SHED AND ROADWAY REQUIRED BY CODE BC 3307.4.7 CREATING H | Oct 18, 2022 | Found in violation | — |
| 1597258 | Jun 16, 2022 | FAILED TO PROVIDE TEMPORARY LIGHTING FOR CONSTRUCTION SITES BC 3303.2.3.1 REQUIRED BY BC 3303.1. ON 7 STORY NB SITE OBSERVE WORKERS WORKING IN DARK/UNLIT SITE WITH CONSTRUCTION ITEMS THROUGHOUT FLOOR ESPECIALLY | Oct 18, 2022 | Found in violation | — |
| 039502371M | Jun 16, 2022 | MISCELLANEOUS VIOLATIONS | Jan 24, 2023 | Found in violation | — |
| 039502368L | Jun 16, 2022 | MISCELLANEOUS VIOLATIONS | Oct 18, 2022 | Found in violation | — |
| 039502369N | Jun 16, 2022 | MISCELLANEOUS VIOLATIONS | Oct 18, 2022 | Found in violation | — |
| 039502370K | Jun 16, 2022 | MISCELLANEOUS VIOLATIONS | Oct 18, 2022 | Found in violation | — |
| 035642278R | Jan 19, 2022 | JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SECTION | Sep 20, 2022 | Found in violation | — |
| 1572593 | Jan 19, 2022 | JOBSITE FENCE INADEQUATE/NOT MAINTAINED. AT TIME OF INSPECTION,I OBSERVED A CONSTRUCTION FENCE INSTALLED AT EXP#1-THE CONSTRUCTION FENCE NEEDS TO BE MAINTAINED HUNTER GREEN,REMOVE ADVERTISEMENTS,FIX LEANING/DAM | Sep 20, 2022 | Found in violation | — |
| 046965325X | May 26, 2021 | DIRTY SIDEWALK DIRTY AREA | Sep 27, 2021 | SETTL IN-VIO | — |
| 0177708466 | Aug 17, 2010 | DIRTY SIDEWALK DIRTY AREA | Sep 27, 2010 | Pending | — |
| 0160891529 | Jul 15, 2008 | DIRTY SIDEWALK DIRTY AREA | Aug 25, 2008 | Pending | — |
| 0108683722 | Jan 3, 2001 | SNOW, ICE DIRT ON SIDEWALK | Jan 31, 2001 | Written off | — |