| 049258157M | Oct 7, 2025 | FAILURE TO CLEAN 18 INCHES INTO STREET | Jan 5, 2026 | Found in violation | — |
| 047350000N | Oct 25, 2021 | FAILURE TO CLEAN 18 INCHES INTO STREET | Jan 24, 2022 | Pending | — |
| 035447329Y | Dec 30, 2019 | MISCELLANEOUS VIOLATIONS | Oct 13, 2020 | Found in violation | — |
| 035447328M | Dec 30, 2019 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE | Oct 13, 2020 | Found in violation | — |
| 376241 | Dec 30, 2019 | 3307.2.1=FAILURE TO COMPLY WITH DOT REGULATIOSN EXPIRED PERMIT NOET AT THE TIME OF MY INSPECTION OF AN ACTIEV JOBSIET I OBSERVED JERSEY BARRIERS BLOCKING THE STREET UPON REVIEW REQUEST FOR DOT PERMIT WHAT WAS P | Oct 13, 2020 | Found in violation | — |
| 375993 | Dec 30, 2019 | COMPETENT PERSOSN NOTE AT THE TIME OF INSPECTION OF AN ACTIEV JOBSITE UPON REQUEST FOR COMPETTENT PERDSONS TO 4 WORKERS THAT WAS PERFORMING CONSTUCTION ACTIVITIES NONE WAS PROVIDED COMPETETNT PERSON SHALL BE PR | Oct 13, 2020 | Found in violation | — |
| 1460521 | Dec 10, 2019 | AT TIME OF ENERGY CODE INSPECTION I OBSERVED A 6 STORY MIXED USE BLDG FRAMED TO 6TH FL EXCLUDING BULKHEAD WITH SUBSTANDARD INSTALLATION ON EXP #2& #4 FROM 1ST THROUGH 6TH FLOOR CONSTRUCTION DOES NOT MEET THE MI | Oct 13, 2020 | Found in violation | — |
| 035408166R | Dec 10, 2019 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AMENDMENTS | Oct 13, 2020 | Found in violation | — |
| 035424168K | Oct 21, 2019 | MISCELLANEOUS VIOLATIONS | Feb 2, 2021 | Found in violation | — |
| 352075 | Oct 21, 2019 | GUARDRAILS SYSEM AND DEBRIS NETTING;NOTE AT TIME OF MY INSPECTION OF A6 STORY BUILDING AT ROOF LEVEL UNDER CONSTRUCTION I OBSERVED THAT THE SUPPORTED PIPE SCAFFOLD INSTALLED AROUND THE BUILDING UP TO ROOF LEVEL | Feb 2, 2021 | Found in violation | — |
| 352442 | Oct 21, 2019 | NO DESIGN DRAWING;WORK DOES NOT CONFORM AS PER DRAWING NOTE:AT TIME OFINSPECTION OF A 6 STORY BUILDING AT ROOF LEVEL UNDER CONSTRUCTION I OBSERVED THAT THE SUPPORTED SCAFFOLD INSTALLED AT EXPOSURE-2 AND 4 ON NE | Feb 2, 2021 | Found in violation | — |
| 352318 | Oct 21, 2019 | BC3314.13.2/VETICAL JOINING FOR PIPE SCAFFOLD;NOTE;AT TIME OF MY INSPECTION OF A 6 STORY BUILDING AT ROOF LEVEL UNDER CONSTRUCTION I OBSERVED THAT THE SUPPORTED SCAFFOLD INSTALLED AROUND THE BUILDING U P TO ROO | Feb 2, 2021 | Found in violation | — |
| 035424167Z | Oct 21, 2019 | MISCELLANEOUS VIOLATIONS | Feb 2, 2021 | Found in violation | — |
| 035424169M | Oct 21, 2019 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33 | Feb 2, 2021 | Found in violation | — |
| 011278979K | Sep 2, 2011 | CERTIFICATES OF FITNESS AND CERTIFICATES OF QUALIFICATION | Oct 17, 2011 | Found in violation | — |
| 010984986K | Sep 6, 2007 | FAILED TO OBTAIN CERTIFICATE OF FITNESS | Oct 22, 2007 | Defaulted (did not respond) | — |
| 0150157251 | Nov 29, 2005 | DIRTY SIDEWALK | Dec 30, 2005 | Pending | — |