| 035215890R | Feb 8, 2017 | ALTERED CHANGED BUILDING OCCUPIED WITHOUT A VALID CERT OF OCCUPANCY | Mar 20, 2018 | Written off | — |
| 1592947 | Feb 8, 2017 | ALTERED/CHANGED BLDG OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCY AS PER 29-118.3.1 - 28-118.3.2 JOB APP #401500988 APPROVED ON 12/17/2004-TO CONVERT 3FAMILY TO 4 FAMILIES. GARAGE INTO A CLASS"A" APT - JOB AP | Mar 20, 2018 | Written off | — |
| 034660073X | May 30, 2008 | ADDITIONAL DAILY PENALTY FOR CONTINUED VIOLATION OF 27-118.1 A -1 2 | Mar 3, 2009 | Written off | — |
| 034660068L | May 30, 2008 | WORK WITHOUT A PERMIT. | Mar 3, 2009 | Written off | — |
| 639414 | May 30, 2008 | RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES. DEPT OF BUILDINGS RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED FOR 3 FAMILY. 4 FL PART OF DWELLING 3RD F | Mar 3, 2009 | Written off | — |
| 640009 | May 30, 2008 | ALTERED BUILDING OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCY: NOTED:ALT TYPE 1 #40150098 TO CONSTRUCT NEW INTERIOR NON LOAD BEARING PARTITIONS AND ADDITIONAL PLUMBING. JOB WAS NOT SIGNED OFF AT TIME OF INSPEC | Mar 3, 2009 | Written off | — |
| 1222139 | May 30, 2008 | WORK W/O A PERMIT. WORK NOTED: AT 4TH FL REMOVED HATCH DOOR TO ROOF AND INSTALLED METAL DOOR WITH FRAME APPROX 3'-0 X 80'-0 HIGH. ALSO AT 4 FL ERECTED FULL HIGH PARTITIONS ABOVE STAIR TO 3RD FL, AND INSTALLED | Mar 3, 2009 | Written off | — |
| 034660074H | May 30, 2008 | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. | Mar 3, 2009 | Written off | — |
| 034338817Y | Sep 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 635364 | Sep 18, 2002 | PLASTIC SKYLINGT SAK TOP OF STAIR ENCLOSER ARE NOT PERMITTED. SKYLINGTS ARE NOT VENTED AND NO PROPER WIRE GRATING PROVIDED ABOVE AND BELOW SKYLINGT. REMEDY: PROVIDE PROPER SKYLINGT AND GRATING. | Feb 12, 2003 | Written off | — |
| 034338588J | Jul 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 636094 | Jul 18, 2002 | FAILURE TO PROVIDE ACCESS TO ROOF VIA INTERIOR STAIR NO ROOF BULKHEAD PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROVIDE REQUIRED ACCESS TO ROOF. | Feb 12, 2003 | Written off | — |
| 034338587H | Jul 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 634557 | Jul 18, 2002 | BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION ( PARARPET WALL ) REMEDY : RAISE FLUE PIPE 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION | Feb 12, 2003 | Written off | — |
| 034338676J | Jul 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 634392 | Jul 18, 2002 | EXTERIOR GAS SERVICES NOT PROPERLY PROTECTED BY BOLLARDS FROM VEHICULAR TRAFFIC AT 1ST FLOOR PARKING AREA REMEDY : PROVIDE ADDITIONAL PROTECTION AROUND GAS SERVICE | Feb 12, 2003 | Written off | — |
| 034338807K | Jul 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 634339 | Jul 18, 2002 | GUARD RAILS ARE NOT PROVIDED AT SECTIONS OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY - PROVIDE GUARD RAILS AT PARAPET REMEDY LEVEL AT ROOF | Feb 12, 2003 | Written off | — |
| 034338839P | Jul 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 034338828J | Jul 18, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 635090 | Jul 18, 2002 | DID NOT PROVIDE MIN 8% STREET FRATAGE AS REQUIRED. REMEDY: PROVIDE WAIVER FROM F.D. AND RECENSIDERATION FROM B.C | Feb 12, 2003 | Written off | — |
| 636307 | Jul 18, 2002 | LOT LINE WINDOWS ARE IMPROPERLY USED TO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION. | Feb 12, 2003 | Written off | — |
| 633811 | Jul 10, 2002 | FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARE | Feb 12, 2003 | Written off | — |
| 636357 | Jul 10, 2002 | CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELF CLOSING DOOR AND NO RATED WALL ST TOP OF STAIR. REMEDY: PROVIDED RATED ENCLOSED AND FIRE PROOF SELF CLOSING DOOR AT TOP AF STAIRS. | Feb 12, 2003 | Written off | — |
| 636527 | Jul 10, 2002 | LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS. | Feb 12, 2003 | Written off | — |
| 034338850X | Jul 10, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 034340886K | Jul 10, 2002 | WORK WITHOUT A PERMIT. | Feb 12, 2003 | Written off | — |
| 034333536P | Jul 10, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 034338686N | Jun 10, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 634761 | Jun 10, 2002 | 1-HOUR RATED BOILER ENCLOUSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTERGRITY OF ONE HOUR RATED WALL REMEDY - PROVIDE 1-HOUR FIRE PROTECTION AROUND BOILER FLUE | Feb 12, 2003 | Written off | — |
| 034338397R | Jun 7, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 034340897X | Jun 7, 2002 | MISCELLANEOUS CONSTRUCTION VIOLATION. | Feb 12, 2003 | Written off | — |
| 634223 | Jun 7, 2002 | WORK CONTRARY TO PLANS IN THAT GRAGE DIMENSIONS SMALLER THAN SPECIFIED(2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL AND CONCRETE (3) REAR LOT RETAINING WALL NOTE SHOWN ON PLANS (4) CURB CUT IS 55 FEE | Feb 12, 2003 | Written off | — |
| 636818 | Jun 7, 2002 | APARTMENT DOOR OPENS DIRECTLY TO STAIRS ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER (3) THREE STORIES. REMEDY: COMPLY WITH CODE. | Feb 12, 2003 | Written off | — |