| 049269945R | Jul 9, 2025 | IMPROPER DISPOSAL--BEDDING 1ST OCCURRENCE | Oct 7, 2025 | Pending | — |
| 1565657 | Jul 18, 2018 | 61N11.71X10.2X10.70M7.77M7.61N11-MARALINO FUSES BY PASSED(2,100AMP)REPLACE 71-X-10.PIT LIGHT INOPERATIVE.20 LIMITS SWITCHES MISSING COVERS PROVIDE 70-M-9 77-M-7 UNDER CAR OUTLET HANGING,NOT SECURED,NO COVER,SEC | Sep 24, 2018 | Defaulted (did not respond) | — |
| 038263584Y | Jul 18, 2018 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Sep 24, 2018 | Defaulted (did not respond) | — |
| 011278783Z | Aug 9, 2011 | POSTING OF PERMITS AND RECORD KEEPING | Sep 27, 2011 | Written off | — |
| 011232431L | Jun 10, 2010 | OPEN FIRES, OPEN FLAMES AND SPARKS | Jan 11, 2011 | Written off | — |
| 011232432N | Jun 10, 2010 | AFFIDAVITS, DESIGN INSTALLATION DOCUMENTS, AND OTHER DOCUMENTATION | Oct 26, 2010 | Written off | — |
| 011165383Z | May 29, 2010 | CERTIFICATES OF FITNESS AND CERTIFICATES OF QUALIFICATION | Jul 20, 2010 | Written off | — |
| 011134095M | Jul 23, 2009 | ELECTRICAL LIGHTING HAZARDS | Sep 8, 2009 | Written off | — |
| 011134096Y | Jul 23, 2009 | POSTING OF PERMITS AND RECORD KEEPING | Sep 8, 2009 | Written off | — |
| 011130278R | Apr 23, 2009 | LABELS MARKINGS | Jun 9, 2009 | Written off | — |
| 038199974X | Jan 20, 2009 | FAIL MAINTAIN BLDG IN COMPLIANT MANNER: SERVICE EQUIPMENT | Aug 31, 2009 | Written off | — |
| 1047256 | Jan 20, 2009 | 97X10,97X17,100R09,08R09,97O02,70O02,73O02,74O02,16I10,15M07,09I10,12X10,03I10,40P16,39P16,52P16,77P16.97X-REPAIR & RESTORE TO SERVICE,FOR FULL INSPECTION BY THIS DEPT.100R-REMOVE ACTIVE SODA MACHINE FROM CAR. | Aug 31, 2009 | Written off | — |
| 411279 | Nov 24, 2008 | 97X10.97X17.100R09.08R09.97O02.70O02.73O02.74O02.26D06.16I10.15M07.09I10.12X10.03I10.03Q03.40P16.97Z REPAIR & RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THIS DEPT 100R REMOVE SOA MACHINE & EXTENSIO | Jan 12, 2009 | Written off | — |
| 038198800L | Nov 24, 2008 | FAIL MAINTAIN BLDG IN COMPLIANT MANNER: SERVICE EQUIPMENT | Jan 12, 2009 | Written off | — |
| 010912115M | Sep 16, 2005 | FAILED TO PROVIDE LIGHTING DEVICES | Nov 1, 2005 | Pending | — |
| 0145160602 | Nov 22, 2004 | ILLEGAL POSTING OF HANDBILL NOTICE | Jan 28, 2005 | Pending | — |
| 0145160611 | Nov 22, 2004 | ILLEGAL POSTING OF HANDBILL NOTICE | Jan 28, 2005 | Pending | — |
| 0145160620 | Nov 22, 2004 | ILLEGAL POSTING OF HANDBILL NOTICE | Jan 28, 2005 | Pending | — |
| 0145160630 | Nov 22, 2004 | ILLEGAL POSTING OF HANDBILL NOTICE | Jan 28, 2005 | Pending | — |
| 010797835J | Jul 30, 2002 | FAILED TO PROVIDE LIGHTING DEVICES | Sep 17, 2002 | Written off | — |
| 010701249H | Jul 31, 2001 | FAILED TO PROVIDE LIGHTING DEVICES | Sep 18, 2001 | Written off | — |
| 010646919Z | Aug 5, 1999 | FAIL TO PROVIDE REQUIRED AFFIDAVIT PLANS | Sep 21, 1999 | Written off | — |
| 010521202M | Aug 12, 1998 | FAILED TO PROVIDE LIGHTING DEVICES | Sep 29, 1998 | Written off | — |
| 485869 | Sep 26, 1994 | FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT LIGHT PURSUANT BEC STANDARDS.FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT/DIRECTIONALSIGNS PURSUANT TO BEC STANDARDS.REMEDY:PROVIDE ADEQUATE EMERGENCY | May 1, 1995 | Written off | — |
| 566141 | Jan 3, 1994 | FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT LIGHT PURSUANT BEC STANDARDS. FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT/ DIRECTIONAL SIGNS PURSUANT TO BEC STANDARDS. REMEDY: PROVIDE ADEQUATE EMERGENCY P | Feb 14, 1994 | Written off | — |
| 557767 | Oct 30, 1992 | FAILURE TO PROVIDE ELEVATOR LANDING SIGNS.FAILURE TO PROVIDE STAIR IDENTIFICATION SIGNS(BOTH STAIRS"A"AND "B").REMEDY:PROVIDE SIGNAGE PER LOCAL LAW 16/84. | Apr 26, 1993 | Written off | — |
| 65639 | Sep 4, 1991 | FAILURE TO PROVIDE ELEVATOR SIGNS (10"X12")AT EACH LANDING NEAR CALL BUTTON. FAILURE TO PROVIDE FLOOR NUMBER SIGNS ON STAIRCASE SIDE ON EACHFLOOR. FAILURE TO PROVIDE LETTER ON HALLWAY SIDE OF DOORS ON EACH FLOO | May 4, 1992 | Found in violation | — |
| 40808 | Aug 5, 1991 | 73X,(73)RESTORE ELEVATOR SERVICE FOR COMPLETE INSPECTOR. | Nov 18, 1991 | Found in violation | — |
| 544255 | May 21, 1991 | FAILURE TO PROVIDE EMERGENCY EXIT LIGHT IN THE BASEMENT CORRIDORS FAILURE TO PROVIDE EMERGRNVY POWER TO EXIT DIRECTIONAL SIGNS THROUGHOUT FLOORS 1 THROUGH 5 REMEDY PROVIDE EMERGENCY POWER LIGHT AND EMERG PWR TO | Jun 15, 1992 | Written off | — |
| 70353 | May 13, 1991 | 73P,73. RETURN TO SERVICE SO THAT PROPER INSPECTION CAN BE MADE BY THIS DEPARTMENT. | Jun 22, 1992 | Found in violation | — |