| 014253949H | Jun 5, 2026 | AFFIDAVITS, DESIGN INSTALLATION DOCUMENTS, AND OTHER DOCUMENTATION | Jul 22, 2026 | Defaulted (did not respond) | $1,000.00 |
| 047953419P | Nov 10, 2023 | FAILURE TO CLEAN 18 INCHES INTO STREET | Feb 9, 2024 | Defaulted (did not respond) | — |
| 014055974M | Mar 14, 2023 | INSPECTION AND TESTING | May 3, 2023 | Defaulted (did not respond) | — |
| 0702903044 | Feb 1, 2022 | OBSTRUCTION OF STREET W CONSTRUCTION MATERIALS EQUIPMENT W O PERMIT | Sep 26, 2022 | Found in violation | $750.00 |
| 035632719Y | Oct 19, 2021 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AMENDMENTS | Jun 2, 2022 | Admitted the violation | — |
| 1628246 | Oct 19, 2021 | 3301.2 FAILURE TO INSTITUTE AND MAINTAIN SAFETY MEASURES DURING CONSTRUCTION FOR STAIR EGRESS.FAILURE TO MAINTAIN VERTICAL CLEARANCE ABOVE STAIR TREAD TO ANY OVERHEAD OBSTRUCTION OF MINIMUM 6FT 8IN PER 1910.25 | Jun 2, 2022 | Admitted the violation | — |
| 1488789 | Oct 19, 2021 | WORK NOT CONFORMING TO PLANS.SUPPORTED SCAFFOLD AND DEBRIS CHUTE.AT TIME OF INSPECTION ON AN ACTIVE 5 STORY ALT1 SITE IN DEMO/STRUCTURE PHASE,OBSERVED SUPPORTED SCAFFOLD AT EXPO1,3 WITH DEBRIS CHUTE IN PLACE UP | Jun 2, 2022 | Admitted the violation | — |
| 1488730 | Oct 19, 2021 | 3314.1 SUPPORTED SCAFFOLD NOT COMPLY WITH CODE.AT TIME OF INSPECTION ON AN ACTIVE 5 STORY SITE IN DEMO/STRUCTURE PHASE,OBSERVED SUPPORTED SCAFFOLD IN PLACE AT EXP1 AND 3.NOTE:PLATFORMS MADE OF ALUMINUM NOT TIED | Jun 2, 2022 | Admitted the violation | — |
| 1624829 | Oct 19, 2021 | FAILURE TO PROVIDE ONSITE DOCUMENTS REQUIRED BY CHAPTER 33.AT TIME OF INSPECTION ON AN ACTIVE 5 STORY ALT1 SITE IN DEMO/STRUCTURE PHASE,I OBSERVED 1 MATERIAL/DEBRIS STORED ON FLOORS/TEMPORARY PLATFORM THAT WA | Jun 23, 2022 | Admitted the violation | — |
| 035632718M | Oct 19, 2021 | MISCELLANEOUS VIOLATIONS | Jun 2, 2022 | Admitted the violation | — |
| 035632716Z | Oct 19, 2021 | MISCELLANEOUS VIOLATIONS | Jun 2, 2022 | Admitted the violation | — |
| 035632717K | Oct 19, 2021 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33 | Jun 23, 2022 | Admitted the violation | — |
| 1696362 | Sep 28, 2021 | DOCS TO BE KEPT ONSITE (MANUFACTURER SPEC) ATOI OF ACTIVE 5STYALT1 W/APRX25WORKERS ONSITE I OBSERVED COLDFORM STEEL IN PLACE FROM CELLAR TO 5STY LEVEL.REQUESTED FOR MANUFACTURERS SPEC NON WAS PROVIDED.DOC REQUI | Nov 10, 2022 | Found in violation | $1,250.00 |
| 1696361 | Sep 28, 2021 | 28-105.12.2 WORK CONTRARY TO PLAN (DEBRIS CHUTE) ATOI OF 5STYALT1 W/APRX25WORKERS ONSITE I OBSERVED@EXP1 DEBRIS CHUTE IN PLACE CONNECTED TO SUPPORTED PIPE SCF.PLANS PROVIDED SHOW CHUTE TO BE PROVIDED@BASE NOT P | Nov 10, 2022 | Found in violation | $2,500.00 |
| 1696360 | Sep 28, 2021 | WORK CONTRARY TO PLAN (SUPPORTED PIPE SCF) ATOI OF ACTIVE 5STYALT1 W/APRX25WORKERS ONSITE I OBSERVED SUPPORTED PIPE SCF IN PLACE@EXP1&3 REQUESTED FOR DRAWING.DRAWING PROVIDED BUT DOESNT SHOW MULTIPLE PIPE BRACI | Nov 10, 2022 | Found in violation | $2,500.00 |
| 035592710Y | Sep 28, 2021 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33 | Nov 10, 2022 | Found in violation | $2,500.00 |
| 1696359 | Sep 28, 2021 | ATOI OF ACTIVE 5STYALT1 W/APRX25WORKERS ONSITE IN DEMO STAGE I REQUESTED FOR SSP,PLAN WAS PROVIDED BUT INADEQUATE MISSING APRX12-17PGS.FACADE WALL HAS BEEN REMOVED@EXP1&3 FROM GRADE LEVEL TO 5STY LEVEL.THIS IS | Nov 10, 2022 | Found in violation | $2,500.00 |
| 035592711X | Sep 28, 2021 | WORK DOES NOT CONFORM TO APPROVED CONST. DOCUMENTS AND OR APPROVED AME | Nov 10, 2022 | Found in violation | $2,500.00 |
| 035592712H | Sep 28, 2021 | MISCELLANEOUS VIOLATIONS | Nov 10, 2022 | Found in violation | $2,500.00 |
| 035592713J | Sep 28, 2021 | FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33 | Nov 10, 2022 | Found in violation | $1,250.00 |
| 0702759934 | Aug 11, 2021 | COMMERCIAL REFUSE CONTAINERW O PROPER REFLECTIVE MARKING ON ALL 4SIDES | Nov 8, 2021 | Defaulted (did not respond) | — |
| 035583322H | Jul 8, 2021 | WORK DOES NOT CONFORM TO APPROVED CONST. DOCUMENTS AND OR APPROVED AME | Mar 3, 2022 | Found in violation | — |
| 562189 | Jul 8, 2021 | WORK DOESNT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.ATOI OF 5STYALT1 ACTIVE JOBSITE,OBSERVED SUPPORTED PIPE SCF INSTALLED@EXP2 REARYD&EXP3.UPON REQUEST TO REV APPROVED SUPPORTED PIPE SCF DRAWING | Mar 3, 2022 | Found in violation | — |
| 561328 | Jul 8, 2021 | PERMIT HOLDER FAILED TO ENSURE WORKERS ATTEND PRESHIFT SAFETY MEETING.ATOI OF 5STYALT1 ACTIVE JOBSITE,OBSERVED 13WORKERS@SITE PERMFORMING STEELWORK.UPON REQUEST FROM SUPER OF CONST FOR WORKERS PRESHIFT SIGNIN S | Mar 3, 2022 | Found in violation | — |
| 035583320Y | Jul 8, 2021 | FAILED TO ENSURE WORKERS RECEIVE SITE SAFETY ORIENTATION OR REFRESHER | Mar 3, 2022 | Found in violation | — |
| 035583321X | Jul 8, 2021 | FAILED TO ENSURE WORKER ATTENDED PRE-SHIFT SAFETY MEETING | Mar 3, 2022 | Found in violation | — |
| 561207 | Jul 8, 2021 | PERMIT HOLDER FAILED TO ENSURE WORKERS REC SITE SAFETY ORIENTATION.ATOI OF 5STYALT1 ACTIVE JOBSITE,OBSERVED 13WORKERS@SITE PERFORMING STEEL WORK.UPON REQUEST FROM SUPER OF CONST FOR WORKERS SITE SAFETY ORIENTAT | Mar 3, 2022 | Found in violation | — |
| 1294138 | May 3, 2021 | WORK CONTRARY TO PLANS(SWS). AT TIME OF INSPECTION OF AN 5 STY ALT-1 IOBSERVED SWS IN PLACE AT EXP#1 W/SUPPORTED PIPE SCFFOLD LOCATED ONLY. UPON FURTHER REVIEW OF SWS PLANS,I NOTICED NOT BUILT TO PLAN MISSING | Jan 27, 2022 | Admitted the violation | — |
| 035556437Y | May 3, 2021 | MISCELLANEOUS VIOLATIONS | Jan 27, 2022 | Admitted the violation | — |
| 035556438X | May 3, 2021 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AMENDMENTS | Jan 27, 2022 | Admitted the violation | — |
| 035556439H | May 3, 2021 | FAILURE TO NOTIFY THE DEPT PRIOR TO THE COMMENCEMENT OF EARTHWORK | Jan 27, 2022 | Admitted the violation | — |
| 035556440P | May 3, 2021 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AMENDMENTS | Jan 27, 2022 | Admitted the violation | — |
| 1294069 | May 3, 2021 | WORK CONTRARY TO PLANS(SHORING). AT TIME OF INSPECTION OF AN 5 STY ALT-1. I OBSERVED SHORING IN PLACE @ EXP#1 FROM BASEMENT TO 5 STY LEVEL W/WOOD & METAL MEMBERS. I REQUESTED FOR SHORING DETAILS BUT INADEQUATE | Jan 27, 2022 | Admitted the violation | — |
| 1294057 | May 3, 2021 | SEC. BC3310.3 NO INADEQUATE SSP(SITE SAFETY PLAN). AT TIME OF INSPECTION OF AN 5 STY ALT 1 I OBSERVED SSP TO SHOW ALL WORK ON SITE. SSP WAS PROVIDED BUT NOT A COMPLETE SET MISSING PAGE 200.00-610.00. I OBSERVED | Jan 27, 2022 | Admitted the violation | — |
| 1294090 | May 3, 2021 | NO EARTH WORK NOTIFICATION. AT TIME OF INSPECTION OF A 5 STY ALT-1 I OBSERVED 3 HOLES IN BASEMENT APPROX 6 FOOT IN DEPTH I REQUESTED FOR EARTHWORK NOTIFICATION NONE WAS PROVIDE HOLE ARE FOR PREPERATION OF UNDER | Jan 27, 2022 | Admitted the violation | — |
| 047134299K | May 1, 2021 | FAILURE TO CLEAN 18 INCHES INTO STREET | Jul 30, 2021 | Defaulted (did not respond) | — |
| 035508977Z | Mar 15, 2021 | PEDESTRAIN PROTECTION DOES NOT MEET CODE SPECIFICATIONS | Feb 24, 2022 | Found in violation | — |
| 1601621 | Mar 15, 2021 | PEDESTRIAN PROTECTION. AT THE TIME OF INSPECTION OF 5 STORY BUILDING UNDER ALTERATION OBSERVED INADEQUATE PEDESTRIAN PROTECTION AT EXP#1 AS FOLLOWING:(1)SWS IS NOT EXTENDED ON BOTH SIDES AS REQUIRED PER SECTION | Feb 24, 2022 | Found in violation | — |
| 0209319734 | Jan 25, 2020 | FAILURE TO PROPERLY PUT RECYCS OUT FOR COLLECTION 1TO8DWELLING UNITS | Mar 2, 2020 | Defaulted (did not respond) | — |
| 011686847L | Jun 11, 2019 | INSPECTION AND TESTING | Jul 31, 2019 | Defaulted (did not respond) | $5,000.00 |
| 011668182R | Jan 18, 2019 | INSPECTION AND TESTING | Mar 6, 2019 | Defaulted (did not respond) | — |
| 0197091869 | Jul 14, 2017 | FAILURE TO CLEAN 18 INCHES INTO STREET | Aug 11, 2017 | Found in violation | — |
| 011504532R | Nov 16, 2016 | CERTIFICATES OF FITNESS AND CERTIFICATES OF QUALIFICATION | Jan 4, 2017 | Defaulted (did not respond) | — |
| 011479794P | May 20, 2016 | INSPECTION AND TESTING | Jul 6, 2016 | Defaulted (did not respond) | — |
| 044190357R | Jul 12, 2014 | STORAGE OF RECEPTACLES - 2ND OFFENSE | Aug 12, 2014 | Pending | — |
| 043960252M | Mar 25, 2014 | STORAGE OF RECEPTACLES - 2ND OFFENSE | Apr 25, 2014 | Pending | — |
| 011331760X | May 15, 2013 | INSPECTION AND TESTING | Jul 3, 2013 | Defaulted (did not respond) | — |
| 0170294603 | May 6, 2013 | STORAGE OF RECEPTACLES | Jun 4, 2013 | Defaulted (did not respond) | — |
| 040207735H | Jul 30, 2012 | RECYC PLACED FOR COLLECTION W NON-RECYC 1 TO 8 DWELLING UNITS | Aug 31, 2012 | Defaulted (did not respond) | — |
| 0178165956 | Apr 28, 2012 | STORAGE OF RECEPTACLES | Jun 4, 2012 | Pending | — |
| 0180452590 | Mar 2, 2012 | NO NOTICE TO DOT BEFORE START PHASE OF WORK ON PROTECTED STREET | Apr 30, 2012 | Pending | — |
| 0173937033 | Jan 29, 2012 | STORAGE OF RECEPTACLES | Mar 26, 2012 | Pending | — |
| 0180286343 | Jan 1, 2012 | USE OPENING OF STREET W O PERMIT | Feb 27, 2012 | Pending | — |
| 0180220509 | Dec 27, 2011 | DOING NON-EMERGENCY WORK WITH AN EMERGENCY AUTHORIZATION NUMBER | Feb 13, 2012 | Pending | — |
| 0173876001 | Dec 7, 2010 | STORAGE OF RECEPTACLES | Jan 4, 2011 | Defaulted (did not respond) | — |
| 0171568129 | Jun 18, 2010 | RECYCLABLES PLACED FOR COLLECTION WITH NON-RECYCLABLES 1ST VIOLATION | Jul 19, 2010 | Pending | — |
| 0170924160 | Jan 11, 2010 | RECYCLABLES PLACED FOR COLLECTION WITH NON-RECYCLABLES 1ST VIOLATION | Mar 8, 2010 | Defaulted (did not respond) | — |
| 010959182K | Mar 21, 2007 | FAIL TO CONDUCT REQUIRED TEST INSPECTION | May 9, 2007 | Found in violation | — |
| 010941128Y | Feb 22, 2007 | FAILED TO PRODUCE PERMIT AND/OR RECORD | Sep 12, 2007 | Defaulted (did not respond) | — |