| 049571459Z | Jan 4, 2026 | STORAGE OF RECEPTACLES NON-COLLECTION DAY | Apr 6, 2026 | Pending | — |
| 035406464X | Jun 24, 2019 | WORK WITHOUT A PERMIT | Sep 3, 2019 | Found in violation | — |
| 1381188 | Jun 24, 2019 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O OR BLDG. DEPT RECORDS C/O#420617693 INDICATE 1ST FL AS 1 CLASS'A'APT & 1 CAR GARAGE. AT TIME OF INSPECTION GARAGE WAS CONVERTED TO CLASS'A'APT W/FULL KITCHEN & 3PC BATH | Sep 3, 2019 | Found in violation | — |
| 1381186 | Jun 24, 2019 | WORK W/O PERMIT. NOTED AT 1ST FL LEVEL FULL HEIGHT PARTITIONS ERECTED AT GARAGE W/WATER & WASTE LINES FOR 3PC BATHROOM(SINK,TOILET,SHOWER)& RESIDENTIAL SINK. ALSO INSTALLING,UNAUTHORIZED ILLEGAL GAS LINE FOR GA | Sep 3, 2019 | Found in violation | — |
| 035406465H | Jun 24, 2019 | OCCUPANCY CONTRARY TO THAT ALLOWED BY CERT OF OCCUP OR BUILDING DEPT | Sep 3, 2019 | Found in violation | — |
| 044284890M | Nov 28, 2016 | NON-RECYC LEFT IN RECYC CONTAINER FOR COLLECTION 1TO8 DWELLING UNITS | Dec 29, 2016 | Pending | — |
| 041197117K | Dec 14, 2015 | LOOSE RUBBISH | Jan 14, 2016 | Defaulted (did not respond) | — |
| 043973433Y | Apr 13, 2015 | NON-RECYC LEFT IN RECYC CONTAINER FOR COLLECTION 1TO8 DWELLING UNITS | May 14, 2015 | Defaulted (did not respond) | — |
| 1052381 | Sep 11, 2013 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTED: AT 4 STY NB UNDER CONSTRUCTION, APPROVED AMENDMENDED PLAN SHOWS 2 STEEL I-BEAMS FROM EXP 2, BEAM (POCKET) TO STAIRCASE | Jan 14, 2014 | Found in violation | — |
| 1052405 | Sep 11, 2013 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORAR CONSTRUCTION - NO TOE BOARDS. NOTED: AT NB UNDER CONSTRUCTION NO TOE BOARDS OBSERVED AT 2ND FLR BALCONY OPENING W/GUARDRAIL SYSTEM AT EXP 1. | Jan 14, 2014 | Found in violation | — |
| 1052383 | Sep 11, 2013 | SEC. BC 3301.7. DESIGN DRAWING REQUIRED BY THE PROVISION OF CHAPTER 33. NOTED: AT 4 STY NB UNDER CONSTRUCTION W/STEEL FRAME ERECTION, NO DESIGN PLAN PRESENTED FOR STEEL CONNECTION FOR BALCONY, STAIRCASE OR | Jan 14, 2014 | Found in violation | — |
| 1052402 | Sep 11, 2013 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO GUARDRAILS. NOTED: AT 1 STY NB UNDER CONSTRUCTION AT2ND FLR @ EXP 3, NO GUARD RAILS OBSERVED FOR EXTERIOR OPENING. REMEDY: | Jan 14, 2014 | Found in violation | — |
| 035032295K | Sep 11, 2013 | WORK DOES NOT CONFORM TO APPROVED CONST. DOCUMENTS AND OR APPROVED AME | Jan 14, 2014 | Found in violation | — |
| 035032296M | Sep 11, 2013 | MISCELLANEOUS VIOLATIONS | Jan 14, 2014 | Found in violation | — |
| 035032297Y | Sep 11, 2013 | FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT ETC.,- NO GUARD RAILS | Jan 14, 2014 | Found in violation | — |
| 035032298X | Sep 11, 2013 | FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES - NO TOE BOARD | Jan 14, 2014 | Found in violation | — |
| 035015465J | Jun 6, 2013 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION | Jul 23, 2013 | Found in violation | — |
| 1051781 | Jun 6, 2013 | FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION. NOTED: AT SITE UNDER APPL #420617693NB W/FOUNDATION FOOTING WORK IN PROGRESS AND OBSERVED APPROX 9' DEEP EXCAVATION(26' X 70')NEAR SHEAR CUT @ EXPS 1,2 & 3 | Jul 23, 2013 | Found in violation | — |
| 035015464H | Jun 6, 2013 | FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION | Jul 23, 2013 | Found in violation | — |
| 1051782 | Jun 6, 2013 | FAILURE TO SAFEGUARD PUBLIC & PROPERTY. NOTED: AT SITE UNDER APPLICATION # 420617693 NB, OBSERVED HORIZONTALLY PROTRUDING RE-BARS AT EYE LEVEL W/O RE-BAR CAPS. STOP ALL WORK AS PER A/C 28-207.2 & SWO POSTED. | Jul 23, 2013 | Found in violation | — |