Open ViolationsA public record project
/

1820 Cortelyou Road, Brooklyn

9 open Class C — see them ↓$1,250.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner

1820 Cortelyou Road at a glance

1820 Cortelyou Road, Brooklyn has 42 open city records on file, 9 of them Class C (immediately hazardous), and $1,250.00 recorded as due on OATH/ECB summonses. The most recent record is dated May 13, 2026.

Open Class C
9
Immediately hazardous — click to see them
Open Class B
31
Hazardous — click to see them
Open Class A
2
Non-hazardous — click to see them
Fines due
$1,250.00
Balance on OATH/ECB summonses
Permits on file
2
Construction permits filed with DOB
Last activity
May 13, 2026
HPD record

Health score for 1820 Cortelyou Road

A composite of the public indicators below. How it is scored.

F
Health score · Aug 5, 2026
Scored from the 300 most recent of 865 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 9
Open Class B violations
Hazardous
This building 31
Heat & hot water records
Violations and complaints, last 24 months
This building 5
Unpaid penalties
OATH/ECB summonses with balance due
This building $1,250
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 1820 Cortelyou Road

Showing the 300 most recent of 865 records; the CSV has the full history. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 1820 Cortelyou Road

$1,250.00 is recorded as due across the 23 summonses below, out of $29,870.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 1820 Cortelyou Road
1835198May 13, 2026ASME A17.1 2.14.57.1 CAR DOOR RESTRICTOR MISSING/ HAS BEEN TEMPERED DIJul 22, 2026Found in violation$1,250.00
1285598Jul 18, 2025CLASS 1 C/U: HAZARDOUS CONDITION: MISSING DOOR INTERLOCK COVER ON 6TH Oct 31, 2025Found in violation
1008272Dec 7, 2022(05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/Feb 15, 2023Found in violation
1332336Mar 23, 2020NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.Oct 2, 2020Found in violation
1316045Aug 28, 2019CEASE USE 42-M-7=SELECTOR TAPE ON CAR TOP MISSING SWITCH (PROVIDE) PERDec 30, 2019Found in violation
1316111Aug 27, 2019CEASE USE 05-A-10,02-X-10=05-A-10 CEASE USE ITEM DOOR ZONE RESTRUCTOR Dec 30, 2019Found in violation
638523Dec 18, 201760Q3,29Q3,59D6,70O2,80M7,6D6,67X10,16P7. SEE NOV# 38258939H FOR RC. (6Apr 2, 2018Found in violation
637992Oct 26, 2017CU 8V10,CU 5M7,CU 59D6,16A10,29Q3,34Q3,39Y2,41W7,60Q3,44B8,58M10,56Y13Dec 11, 2017Found in violation
1446835Oct 30, 201567X10,14M07,26Q03,39Y02,37Y02,39M07,100M07,40Z02,60Q03,40M07,61G11,42GDec 14, 2015Found in violation
397819Jul 28, 2015C/U-72M07,70O02,67M07,60B07,41T07,14M07. C/U-72M07-PIT STOP SWITCH MISDec 14, 2015Found in violation
938619Feb 7, 201472M07,70O02,71M07,67M07,14M07,69M07,68M07,60B07,41T07,97O02. 72M07-PITMar 24, 2014Found in violation
1059785Jan 15, 2014FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER IN THAT IN APT 1A ONMar 31, 2014Found in violation
228704Jul 1, 2013SEC. 240.3 FAILURE TO PROTECT CONDUCTORS,AGAINST OVER CURRENT PER EC BAug 21, 2013Found in violation
228678Jul 1, 2013FAILURE TO GROUND ELECTRICAL SYSTEMS. ELECTRICAL SYSTEM GROUNDING CONDAug 21, 2013Found in violation
228712Jul 1, 2013SEC. 240.53 UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPT. APPARATUS Aug 21, 2013Found in violation
228880Jul 1, 2013SEC. 110.2A VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS DEFECAug 21, 2013Found in violation
1470265Jul 1, 2013ELECTRICAL WORK W/O PERMIT. CELLAR ELECTRICAL WIRING OF BRANCH CIRCUITAug 19, 2013Found in violation
1046714Jan 18, 200616I11/66O02/03B10/28Q06/40W06 16I REPLACE ALL BROKEN AND MISSING VISONMar 6, 2006Written off
324279Oct 13, 200420M07/20I11/20D06/58A07 20-M-2FL HOISTWAY DOOR 20-I- 3 FL 20-D BSMT HONov 30, 2004Settled by stipulation
380847Mar 5, 200460R11/58L10/45R09/10H11/12Q03/34Q03/39D06/08V10/28Q03/41A02/52H14/72E1Apr 19, 2004Found in violation
304549Mar 16, 200114M07,05B01,57O02,22D06,08V01,25M07,09M07,37D06.05-ADJUST CAR DOOR FULJun 25, 2001Found in violation
297412Jul 25, 200017I11/05I11/13I11/11Q03/57O02/18B01/57O02/08V11/05L11/39H12/50Y11/74D0Sep 11, 2000Found in violation
614396Feb 4, 199105J.Jun 10, 1991Written off