Open ViolationsA public record project
/

2410 Barker Avenue, Bronx

3 open Class C — see them ↓$15,625.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner

2410 Barker Avenue at a glance

2410 Barker Avenue, Bronx has 11 open city records on file, 3 of them Class C (immediately hazardous), and $15,625.00 recorded as due on OATH/ECB summonses. The most recent record is dated Feb 1, 2026.

Open Class C
3
Immediately hazardous — click to see them
Open Class B
8
Hazardous — click to see them
Open Class A
0
Non-hazardous — click to see them
Fines due
$15,625.00
Balance on OATH/ECB summonses
Permits on file
24
Construction permits filed with DOB
Last activity
Feb 1, 2026
DOB record

Health score for 2410 Barker Avenue

A composite of the public indicators below. How it is scored.

D
Health score · Aug 6, 2026
Scored from all 220 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 3
Open Class B violations
Hazardous
This building 8
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $15,625
Bedbug filings with infestations
Annual LL69 filings on record
This building 3
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 2410 Barker Avenue

220 records on file, every agency interleaved. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 2410 Barker Avenue

$15,625.00 is recorded as due across the 28 summonses below, out of $50,540.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 2410 Barker Avenue
1798310Oct 1, 2024FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION RJan 3, 2025Defaulted (did not respond)$12,500.00
1780558Aug 26, 2024FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAIN IN SUMMONS#3564739Nov 29, 2024Defaulted (did not respond)$3,125.00
1627833Jun 21, 2022TEMP CONST EQUIPMENT ONSITE-EXPIRED PERMIT.ATOI OBSERVED SIDEWALKSHED Sep 16, 2022Admitted the violation
1627865Jun 21, 2022PEDESTRIAN PROTECTION DOESNT MEET CODE SPECS ATOI OBSERVED SIDEWALKSHESep 16, 2022Admitted the violation
1643865Mar 3, 2022FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.AS NOTEDJun 3, 2022Settled by stipulation
1626832Oct 8, 2021FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A,8A&9A REPORT INDICATING COMar 4, 2022Found in violation
1473094Mar 26, 2021PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS:SIDEWALK SHED Jun 18, 2021Admitted the violation
1149623Feb 11, 2021BC 3314.16.4 INSPECTION OF CORNER ANGLE SCAFFOLD. AT THE TIME OF MY INApr 30, 2021Found in violation
1682522Feb 11, 2021EXPIRED TERM OF PERMIT FOR TEMPORARY EQUIPMENT. AT THE TIME OF MY INSPApr 30, 2021Defaulted (did not respond)
1581297Jan 27, 2021NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OFMar 19, 2021Found in violation
1581295Jan 27, 2021NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OFMar 19, 2021Found in violation
1514258Sep 9, 2020FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS RQUIRED BY CHAPTER 33.ATNov 20, 2020Found in violation
1565976Sep 9, 2020FAILURE TO HAVE SITE SAFETY MANAGER OR COORDINATOR PRESENT AT JOBSITE:Jun 11, 2021Found in violation
1581203Aug 17, 2020NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.Mar 12, 2021Found in violation
1223139Jun 3, 2020FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A REPORT INDICATING CORRECTISep 4, 2020Found in violation
1495931Oct 31, 2019FAILURE TO PROVIDE SIDEWALK SHED PARAPET.SIGN ACCORDING TO 3301.9.2~NOMay 8, 2020Found in violation
1099879Oct 23, 2018PERIODIC INSPECTION. SIX MONTH FOLLOWING THE INITIAL INSTALLATION IN Jan 25, 2019Found in violation
1244396May 18, 2018FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION Nov 2, 2018Found in violation
1291608Apr 25, 2018FAILURE TO NOTIFY DEPARTMENT 24-48 HOURS BEFORE INSTALLATION OF TEMPORJun 15, 2018Found in violation
1398359Sep 18, 201797X10,56Y13,57BB11.97X17 UPON INSPECTION, THE DEVICE IS FOUND TO BE ODec 1, 2017Found in violation
1207204Jun 13, 2017TEMP.CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT.NOTED:AT TIME OF INAug 4, 2017Found in violation
1207207Jun 13, 2017FAILURE TO PROVIDE SIDEWALK SHED PARAPET SIGN ACCORDING TO 33019.2.NOTAug 4, 2017Found in violation
1244193Nov 7, 2016FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSApr 21, 2017Found in violation
1652469Jan 7, 2013FAILURE TO MAINTAIN BLDG WALLS AND APPURTENANCES. NOTED: 1-SPALLED & CMar 1, 2013Settled by stipulation
1641926Apr 18, 2012FAILURE TO MAINTAIN EXTERIOR BLDG.WEST ELEVATION,EXP #1 OBSERVE BROKENJun 15, 2012Found in violation
596683Mar 30, 200785BB5,56B10,66O2.56-HIGH BAR ON MOTOR.May 18, 2007Settled by stipulation
604467Mar 30, 200785BB5,55Y13,66O2.May 18, 2007Found in violation
200238Jul 29, 199816T7,16M12,15L11,16HL,48B15,60U5,. #15-T-7=NUMBERS INSIDE HOISTWAY. Sep 11, 1998Found in violation