Open ViolationsA public record project
/

405 East 182 Street, Bronx

33 open Class C — see them ↓$8,705.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner

405 East 182 Street at a glance

405 East 182 Street, Bronx has 100 open city records on file, 33 of them Class C (immediately hazardous), and $8,705.00 recorded as due on OATH/ECB summonses. The most recent record is dated Jul 20, 2026.

Open Class C
33
Immediately hazardous — click to see them
Open Class B
54
Hazardous — click to see them
Open Class A
13
Non-hazardous — click to see them
Fines due
$8,705.00
Balance on OATH/ECB summonses
Permits on file
4
Construction permits filed with DOB
Last activity
Jul 20, 2026
HPD record

Health score for 405 East 182 Street

A composite of the public indicators below. How it is scored.

F
Health score · Aug 5, 2026
Scored from the 300 most recent of 1,217 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 33
Open Class B violations
Hazardous
This building 54
Heat & hot water records
Violations and complaints, last 24 months
This building 8
Unpaid penalties
OATH/ECB summonses with balance due
This building $8,705
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 405 East 182 Street

Showing the 300 most recent of 1,217 records; the CSV has the full history. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 405 East 182 Street

$8,705.00 is recorded as due across the 29 summonses below, out of $94,843.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 405 East 182 Street
1809480Jul 21, 2024SUMMONS ISSUED FOR WORK WITHOUT A PERMIT DUE TO EXTERIOR FIRE ESCAPE ENov 18, 2025Found in violation$2,500.00
1809481Jul 21, 2024SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE DUE TO UNSECURED BRACKET ONNov 18, 2025Found in violation$1,250.00
1772668Jul 15, 2024OCCUPANCY IN CONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILApr 24, 2025Found in violation$1,250.00
1835038Jan 5, 2024FOUND WEIL MCLAIN STEAM 15PSI BOILER WITH A 30PSI SAFETY VALVE. CEASEDMar 15, 2024Defaulted (did not respond)$3,705.00
1423963Mar 2, 2022CEAS USE BOILER DO TO HIGH CO READING Ý 179 PPM¨ IN BOILER ROOM , REARSep 9, 2022Found in violation
1390439Feb 3, 2020CEASE USE WEIL MCLAIN MODEL #878, DUE TO WATER LEAK COMING FROM BOILERNov 27, 2020Found in violation
1390453Feb 3, 2020BOILER NOT REGISTERED AS PER DOB RECORDS, PULL PERMIT BRING BOILER ANDNov 27, 2020Found in violation
1374225May 28, 2019UNLAWFUL ACTS,FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN AJul 19, 2019Defaulted (did not respond)
545330Apr 18, 2019AN UNLAWFUL ACT.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.FAJun 7, 2019Defaulted (did not respond)
1374200Apr 12, 2019UNLAWFUL ACTS.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.IN MARCMay 31, 2019Defaulted (did not respond)
1392315Mar 8, 2019ELECTRICAL WORK W/O A PERMIT. OBSERVED AT THE TIME OF MY INSPECTION A Nov 29, 2019Found in violation
1752710Mar 6, 2019AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER Nov 29, 2019Found in violation
1752688Dec 10, 2018AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. Apr 12, 2019Found in violation
1536066Oct 22, 2018UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENTS, APPARATUS, MATERIAMar 29, 2019Found in violation
1534769Jul 18, 2018B254,32A,50A,50B,50C,50D. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO Sep 7, 2018Defaulted (did not respond)
1534727Feb 27, 2017B254,101,40,50,36. 50-NEED TO INSTALL PIGTAIL ON PRESSURE CAUSE; 36 Apr 21, 2017Defaulted (did not respond)
1234345Aug 5, 2016ELECTRICAL WORK W/O A PERMIT.THE ENTIRE BLDG HALLWAYS:REPLACING LIGHTIFeb 10, 2017Found in violation
1437713May 24, 2011FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCE NOTED AT SOUTH AND WESTSep 23, 2011Written off
1411025Mar 23, 2011FAILURE TO MAINTAIN.NOTE:SOUTH & WEST FACADES HAVE DEFECTIVE BRICK WORAug 19, 2011Written off
1330996Aug 18, 201050. 50- CHIMNEY INSPECTION DOOR DEFECTIVE WILL NOT STAY CLOSED.Oct 15, 2010Written off
1312674Jul 27, 2010FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES. NOTED: 1) AT SOUTH Sep 17, 2010Written off
1333023Jun 19, 2010FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: PROVIDE REQUIRED COOct 15, 2010Written off
1274582Feb 6, 2010FAILURE TO MAINTAIN BUILDING BUILDING WALLS AND APPURTENANCES.THE BRICApr 2, 2010Written off
1068153Jan 11, 2010FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGE WAY. EXIT GATE AT SE SIDEMar 5, 2010Written off
1068158Jan 11, 2010FENCE EXCEEDS PERMITTED HEIGHT. NOTED: EXIT FENCE/GATE AT RIGHT SIDE Mar 5, 2010Written off
941790Jun 29, 2005BQ9/10/16/32A/34A/36/B4A/50/50A/50B/50C/50D. BQ9-BOILER INSTALLED WITHAug 19, 2005Found in violation
941789Sep 24, 20043B 50A 32A 34A 36 50G 50A 50B 50C 50D 50E 50F 50A EXCESSIVE FOOT ESCAPSep 20, 2011Found in violation
1436661Jul 9, 2004FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: AT THE SOUTH PASep 20, 2011Written off
1742730May 27, 2004PLUMBING WORK WITHOUT A PERMIT GAS PIPING FROM METER TO STOVE REMEDY:OSep 20, 2011Found in violation