Open ViolationsA public record project
/

900 East 167 Street, Bronx

Export CSV
OverviewHealth scoreTimelineFinesOwner

900 East 167 Street at a glance

900 East 167 Street, Bronx has 6 open city records on file, 1 of them Class C (immediately hazardous), and no balance recorded as due on OATH/ECB summonses. The most recent record is dated Dec 3, 2025.

Open Class C
1
Immediately hazardous — click to see them
Open Class B
5
Hazardous — click to see them
Open Class A
0
Non-hazardous — click to see them
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
3
Construction permits filed with DOB
Last activity
Dec 3, 2025
HPD record

Health score for 900 East 167 Street

A composite of the public indicators below. How it is scored.

B
Health score · Aug 5, 2026
Scored from the 300 most recent of 609 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 1
Open Class B violations
Hazardous
This building 5
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 1
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 900 East 167 Street

Showing the 300 most recent of 609 records; the CSV has the full history. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 900 East 167 Street

No balance is recorded as due across the 23 summonses below, out of $23,700.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 900 East 167 Street
1802739Oct 15, 2025FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES.NOTE:AT TIMDec 19, 2025Found in violation
1369611Sep 24, 2018UNAPPROVED, UNSAFE, UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIJul 31, 2019Settled by stipulation
1482333Jun 13, 2018B254,11A,50A,50B,50C. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAIN Nov 9, 2018Found in violation
1298851May 4, 2018AN UNLAWFUL ACT. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. FAILJul 13, 2018Found in violation
980541Dec 4, 2017NO MEASURES OF ENERY CONSUMPTION OF EACH TENANT DWELLING UNIT.OBSERVEDMay 4, 2018Found in violation
980469Dec 4, 2017FAILURE TO GROUND ELECTRICAL SYSTEMS.OBSERVED IN BSMT AREA WATER MAIN May 4, 2018Found in violation
980453Dec 4, 2017UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIAL,APPARATUS,DMay 4, 2018Found in violation
980523Dec 4, 2017FAILURE TO PROVIDE/MAINTAIN SUFFICEIENT ACCESS/WORK SPACE ABOUT ELECTRMay 4, 2018Found in violation
1448102Oct 28, 2017FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VFeb 16, 2018Found in violation
1289736Oct 3, 2017FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:OBSERVED AT THE Feb 2, 2018Found in violation
1273317Aug 31, 2017FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATIONov 17, 2017Found in violation
1079779Jul 28, 2017FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIONov 3, 2017Found in violation
221490May 31, 2017FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN GAS METNov 3, 2017Found in violation
1201011May 31, 2017FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED IN BASEMENT AT WATER MANov 3, 2017Found in violation
1201004May 31, 2017FAILURE TO MAINTAIN BLDG IN CODE C,OMPLIANT MANNER. NOTED: AT CELLAR INov 3, 2017Found in violation
1201014May 31, 2017ELECTRICAL WORK W/O A PERMIT. OBSERVED IN BASEMENT: THE INSTALLATION ONov 3, 2017Found in violation
1267931May 16, 2017FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO #3522218Nov 3, 2017Found in violation
1186166Dec 2, 2016FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. NOTED: CELLAR CEIJan 20, 2017Found in violation
199223Dec 2, 2016FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 12/2/16Jan 20, 2017Found in violation
624827Dec 2, 2016FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 12/2/16Jan 20, 2017Found in violation
1279518Dec 2, 2016SEC. 408.2 MISC VIOLATION DRIPS-FUTURE CONNECTS EXIST DOWN STREAM OF AJan 20, 2017Found in violation
712797Jun 21, 2016FAILURE TO MAINTAIN BLDG CODE COMPLIANT: USE OF PROHIBITED HARDWARE PEAug 12, 2016Found in violation
712713Jun 21, 2016FAILURE TO MAINTAIN BLDG CODE COMPLIANT. NOTED: ON LEFT & RIGHT SIDES,Aug 5, 2016Found in violation