| 049942804K | Jul 14, 2026 | SPILLAGE FROM A RECEPTACLE 1ST OFFENSE | Oct 13, 2026 | Pending | $100.00 |
| 049805587M | Jul 10, 2026 | DIRTY SIDEWALK | Oct 9, 2026 | Pending | $50.00 |
| 049805500K | Jun 24, 2026 | RECYCLABLES PLACED FOR COLLECTION WITH NON-RECYC 9+ DWELLING UNITS | Sep 22, 2026 | Pending | $100.00 |
| 014252873X | Jun 2, 2026 | INSPECTION AND TESTING | Jul 22, 2026 | Found in violation | $750.00 |
| 049848219Z | May 28, 2026 | FAILURE TO CLEAN 18 INCHES INTO STREET | Aug 28, 2026 | Pending | — |
| 049662843R | May 26, 2026 | SPILLAGE FROM A RECEPTACLE 1ST OFFENSE | Aug 24, 2026 | Pending | $100.00 |
| 049791319L | May 26, 2026 | DIRTY SIDEWALK | Aug 24, 2026 | Pending | — |
| 049681170P | May 11, 2026 | FAILURE TO CLEAN 18 INCHES INTO STREET | Aug 10, 2026 | Pending | — |
| 049798433R | Apr 30, 2026 | FAIL TO RECYCLE ORGANIC WASTE 9 OR MORE DWELLING UNITS 1ST | Jul 31, 2026 | Pending | — |
| 049447368P | Dec 29, 2025 | DIRTY SIDEWALK | Mar 30, 2026 | Pending | — |
| 048392764P | Oct 30, 2025 | DIRTY SIDEWALK | Jan 30, 2026 | Defaulted (did not respond) | $300.00 |
| 049367678K | Oct 1, 2025 | FAILURE TO CLEAN 18 INCHES INTO STREET | Dec 30, 2025 | Pending | — |
| 048630834M | Feb 4, 2025 | STORAGE OF RECEPTACLES NON-COLLECTION DAY | May 5, 2025 | Pending | — |
| 012162612X | Dec 17, 2024 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | May 13, 2026 | Found in violation | — |
| 012158498J | Sep 6, 2024 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Jan 8, 2025 | Defaulted (did not respond) | $5,000.00 |
| 012153728N | Jul 11, 2024 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Sep 18, 2024 | Defaulted (did not respond) | $5,000.00 |
| 012151268M | Mar 17, 2024 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Jul 24, 2024 | Defaulted (did not respond) | $5,000.00 |
| 048241002K | Jan 8, 2024 | FAILURE TO CLEAN 18 INCHES INTO STREET | Apr 5, 2024 | Pending | — |
| 012145291J | Jan 5, 2024 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Feb 28, 2024 | Defaulted (did not respond) | $1,000.00 |
| 046985392Y | Sep 18, 2023 | IMPROPER DISPOSAL--BEDDING 1ST OCCURRENCE | Dec 18, 2023 | Defaulted (did not respond) | $300.00 |
| 047581157J | Oct 26, 2022 | DIRTY SIDEWALK | Jan 24, 2023 | SETTL IN-VIO | — |
| 012099332M | Mar 13, 2020 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Oct 21, 2020 | Found in violation | — |
| 012095095J | Nov 8, 2019 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Jan 8, 2020 | Defaulted (did not respond) | — |
| 0206474126 | Jan 17, 2019 | DIRTY SIDEWALK DIRTY AREA | Feb 19, 2019 | Defaulted (did not respond) | — |
| 0192094632 | Jul 16, 2016 | FAILURE TO CLEAN 18 INCHES INTO STREET | Aug 19, 2016 | Defaulted (did not respond) | — |
| 0190387405 | May 21, 2016 | FAILURE TO CLEAN 18 INCHES INTO STREET | Jun 21, 2016 | Defaulted (did not respond) | — |
| 0190385315 | May 7, 2016 | FAILURE TO CLEAN 18 INCHES INTO STREET | Dec 2, 2016 | Defaulted (did not respond) | — |
| 011472644H | Jan 20, 2016 | SIGN, POSTINGS, NOTICES AND INSTRUCTIONS | Mar 9, 2016 | Written off | — |
| 043555390L | Sep 16, 2015 | RECYCLABLES PLACED FOR COLLECTION WITH NON-RECYC 9+ DWELLING UNITS | Oct 19, 2015 | Defaulted (did not respond) | — |
| 0186627210 | Jul 3, 2015 | FAILURE TO BUNDLE NEWSPAPERS MAGAZINES CARDBOARD 9+ DWELLING UNITS | Aug 3, 2015 | Defaulted (did not respond) | — |
| 035088643K | May 1, 2014 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER | Sep 11, 2014 | Written off | — |
| 1554883 | May 1, 2014 | UNLAWFUL ACTS:FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.NOTESWO #35032647P ISSUED ON 10/22/13 FOR NO ROOF PROTECTION @ EXP2 & 4 @ TIME OF INSP OBSERVED WORK COMPLETED STUCCO FINISH & PAINTED PARAPET C | Sep 11, 2014 | Written off | — |
| 035032647P | Oct 22, 2013 | MISCELLANEOUS VIOLATIONS | Jan 30, 2014 | Written off | — |
| 1600509 | Oct 22, 2013 | SEC. 3301.7 DESIGN REQUIRED BY THE CHAPTER 33. NOTED: MECHANICAL PULLEY/HOIST SET UP IN PLACE WHERE GARBAGE SHOOT WILL BE SET UP,USED TO LIFT MATERIAL UP. PARTIAL STOP WORK ORDER ISSUED PURSUANT TO 28-207.2 AND | Jan 30, 2014 | Written off | — |
| 1600195 | Oct 22, 2013 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - INADEQUATE GUARD RAILS. NOTED: ACTIVE JOB SITE,8 STORY BLDG. AT TIME OF INSPECTION OBSERVED GUARD RAILS SET UP NOT UP TO CODE. | Jan 30, 2014 | Written off | — |
| 957796 | Oct 22, 2013 | SEC. 3303.4.4 DEBRIS - NOT CLEANED OFF DAILY FROM FLOORS & ROOF. NOTEDOBSERVED DEBRI THROUGHOUT THE BLDG 1ST INSPECTION (7:30AM),ACTIVE JOB SITE 8 STORY BLDG. CONSTRUCTION DEBRI ALL OVER THE PLACE AS WELL AS | Dec 12, 2013 | Admitted the violation | — |
| 959235 | Oct 22, 2013 | SEC. 3308.3 VERTICAL SAFETY NETTING NOT PER CODE,DAMAGED. NOTED: AT TIME OF INSPECTION OBSERVED VERTICAL SAFETY NETTING ROLLED UP IN PLACES & SECURED W/A WIRE THROUGHOUT THE BLDG. ALSO IN SOME PLACES NETTING IS | Dec 12, 2013 | Admitted the violation | — |
| 1600179 | Oct 22, 2013 | SEC. 3309.10 NO ROOF PROTECTION FOR ADJOINING PROPERTY. NOTED: NEW BLDG TOPPED OFF 8 STORY NO ROOF PROTECTION PROVIDED FOR ADJACENT BLDG'S (209 W 115 ST AT EXP 2 & 205 W 115 ST AT EXP 4). STOP ALL WORK W/I 10FT | Jan 30, 2014 | Written off | — |
| 1600197 | Oct 22, 2013 | SEC. 3303.4.5.1 MATERIAL AT EDGE OF THE BLDG WHEN NOT BEING USED. NOTED: CONCRETE BLOCKS STOCKED 6 BLOCKS & HIGHER STORED ABOUT 3 FEET AWAY FROM THE BLDG EDGE AT ROOF,8 FL,7 FL,6 FL. MASONS ARE WORKING ON 3-4FL | Jan 30, 2014 | Written off | — |
| 035077126Z | Oct 22, 2013 | MISCELLANEOUS VIOLATIONS | Jan 30, 2014 | Written off | — |
| 035032649Z | Oct 22, 2013 | MISCELLANEOUS VIOLATIONS | Jan 30, 2014 | Written off | — |
| 035032646N | Oct 22, 2013 | MISCELLANEOUS VIOLATIONS | Dec 12, 2013 | Pending | — |
| 035077125R | Oct 22, 2013 | MISCELLANEOUS VIOLATIONS | Dec 12, 2013 | Pending | — |
| 035032648R | Oct 22, 2013 | FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT ETC.,- NO GUARD RAILS | Jan 30, 2014 | Written off | — |
| 0182615768 | Sep 18, 2013 | STREET CLOSING WITHOUT PERMIT | Nov 25, 2013 | Written off | — |
| 0182596637 | Sep 7, 2013 | STREET CLOSING WITHOUT PERMIT | Nov 18, 2013 | Written off | — |
| 0182596646 | Sep 7, 2013 | CONSTRUCTION MATERIALS EQUIPMENT STORED ON STREET W 0 PERMIT | Nov 18, 2013 | Written off | — |
| 0182192790 | Apr 11, 2013 | FAILURE TO COMPLY WITH THE TERMS AND CONDITIONS OF DOT PERMITS | Jun 24, 2013 | Defaulted (did not respond) | — |
| 0181894067 | Feb 14, 2013 | NO RAISED PLOW SIGN STEEL PLATES OR FAIL TO COUNTERSINK PLATES W RDWAY | Apr 8, 2013 | Pending | — |