410 West 22 Street at a glance

410 West 22 Street, Manhattan has 13 open city records on file, none of them Class C, and no balance recorded as due on OATH/ECB summonses. The most recent record is dated Mar 20, 2026.

Open Class C
0
Immediately hazardous — click to see them
Open Class B
12
Hazardous — click to see them
Open Class A
1
Non-hazardous — click to see them
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
3
Construction permits filed with DOB
Last activity
Mar 20, 2026
Bedbugs record

Health score for 410 West 22 Street

A composite of the public indicators below. How it is scored.

B
Health score · Aug 5, 2026
Scored from all 172 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 12
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 410 West 22 Street

172 records on file, every agency interleaved. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 410 West 22 Street

No balance is recorded as due across the 12 summonses below, out of $27,300.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 410 West 22 Street
1694731Feb 25, 20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTDec 11, 2025Dismissed
1488401Oct 7, 2020FOUND WEIL MCLAIN STEAM BOILER MODEL SERIES 80-580 ACTIVE WITH DEFECTSDec 3, 2020Defaulted (did not respond)
1488433Oct 7, 2020FOUND WEIL MCLAIN STEAM BOILER MODEL SERIES 80-580 INSTALLED AND UNREGDec 3, 2020Defaulted (did not respond)
1415309Feb 13, 2019PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALAug 29, 2019Found in violation
1437753Feb 12, 2019FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE AT APT 1F. CLASAug 29, 2019Found in violation
486473Feb 12, 2019FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIREAug 29, 2019Found in violation
1294043May 17, 2016PROJECT INFORMATION PANEL/SIDEWALK SHED PARAPET PANEL/CONSTRUCTION SIGJul 7, 2016Resolved
893629Aug 31, 2011FAILURE TO MAINTAIN BLDG IN A CODE-COMPLAINT MANNER: NOTED: DEFECTS ATOct 20, 2011Defaulted (did not respond)
1218943Jun 9, 2000SIDEWALK SHED DOES'NT MEET BLDG CODE SPECIFICATIONS.DEFECT NOTED:A SIDNov 18, 2004Found in violation
1165866Sep 22, 1999SIDEWALK SHED DOES NOT MEET BUILDING CODE SPECIFICATIONS. NOTED: SIDE-Nov 18, 2004Found in violation
1165868Sep 22, 1999FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: NORTH WEST CORNER Nov 18, 2004Found in violation
583094Aug 26, 1991WORK WITHOUT A PERMIT WORK NOTED: CONSTRUCTION OF PARTITIONS AND BATHRNov 7, 1991Written off