Electric lighting fixtures required in certain public parts of dwellings

NYC Housing Maintenance Code § 27-2038 · cited Mar 27, 1990Jul 17, 2026

1,871 NYC housing violations have been issued under NYC Housing Maintenance Code § 27-2038, which is 0.0% of every HPD violation attributed to a section. 610 are still open.

Open now
610
Closed
1,261
All time
1,871
Share of attributed
0.0%
Class C (immediately hazardous)
0

What inspectors cite § 27-2038 for

The most common orders written under this section, in HPD’s own wording.

  1. Provide Adequate Lighting For Light Fixture At Ceiling At · 42
  2. Provide Adequate Lighting For 60 Watts At Public Hall, · 37
  3. Provide Adequate Lighting For 60 Watts Minimum At Public · 35
  4. Provide Adequate Lighting For Ceiling Light Fixture At Public · 23
  5. Provide Adequate Lighting For Not Less Than 60 Watts · 21
  6. Provide Adequate Lighting For The Fixture At Ceiling At · 19

Open § 27-2038 violations by borough

BROOKLYN330
QUEENS113
BRONX109
MANHATTAN29
STATEN ISLAND29

Text of NYC Housing Maintenance Code § 27-2038

§ 27-2038 Electric lighting fixtures required in certain public parts of dwellings.

a. Subject to any stricter minimum lighting requirement that may be applicable pursuant to the multiple dwelling law, in every multiple dwelling and tenant-occupied two-family dwelling light from electric lighting fixtures and daylight shall in the aggregate provide an illumination level of no less than one foot-candle, measured at the floor level, throughout all public hallways, stairs, fire stairs, and fire towers at all times of the day and night and throughout common laundry rooms at all times that such rooms are occupied. The owner shall install, position, operate and maintain sufficient electric lighting fixtures to assure that the required illumination level is maintained.

b. The owner of a multiple dwelling shall keep electric lighting fixtures on continuously, during the day as well as at night, in every fire stair and fire tower and in every stairway and public hall with no window opening on a street, court, yard, space above a setback or shaft supplying sufficient illumination to maintain the required illumination level during the daylight hours.

c. Photosensor lighting controls may be used to control electric lighting fixtures in public halls and stairs according to the amount of daylight available provided that the level of illumination required by subdivision a of this section is maintained at all times and the switch controllers are equipped for fail-safe operation ensuring that if the sensor or control fails, the lighting levels will be at the levels required by subdivision a of this section.

d. Automatic, occupant sensor or photosensor lighting controls may be used to operate lighting fixtures in common laundry rooms, provided that all of the following conditions are satisfied: 1. the switch controllers are equipped for fail-safe operation ensuring that if the sensor or control fails, the lighting levels will be at the levels required by subdivision a of this section; 2. for occupant sensors, the illumination times are set for a maximum thirty minute duration; and 3. for occupant sensors, the sensor is activated by any occupant movement in the area served by the lighting fixtures.

e. For the purposes of this section the term "photosensor" means a device that detects the presence of visible light and the term "occupant sensor" means a device that detects the presence or absence of people within an area and causes lighting to be regulated accordingly. Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2010/052.

Current through Local Law 2026/116, enacted July 11, 2026 · enacted municipal law, in the public domain · official publication

Questions people ask about § 27-2038

What is a § 27-2038 violation?

NYC Housing Maintenance Code § 27-2038, "Electric lighting fixtures required in certain public parts of dwellings", is cited on a violation when an HPD inspector finds the condition it covers. Subject to any stricter minimum lighting requirement that may be applicable pursuant to the multiple dwelling law, in every multiple dwelling and tenant-occupied two-family dwelling light from electric lighting fixtures and daylight shall in the aggregate provide an illumination level of no less than one foot-candle, measured at the floor level, throughout all public hallways, stairs, fire stairs, and fire towers at all times of the day and night and throughout common laundry rooms at all times that such rooms are occupied. The owner shall install, position, operate and maintain sufficient electric lighting fixtures to assure that the required illumination level is maintained.

How many § 27-2038 violations are open in NYC right now?

610 § 27-2038 violations are open as of Aug 4, 2026.

Where this comes from

Counted from HPD’s Housing Maintenance Code Violations dataset. Each notice is attributed to a section by HPD’s own order number where one is on record, otherwise by the section its notice text cites. Figures recomputed Aug 4, 2026.

Browse open § 27-2038 records in the live feed · All violation codes