| 1575858 | Jul 25, 2024 | RESPONDING A COMPLAINT WHERE, FROM FACADE WORK EXPOSURE# 2, PINS INSTA | Oct 2, 2024 | Found in violation | — |
| 1120127 | Jun 9, 2023 | NOTED: AT TIME OF INSPECTION, OBSERVED THAT THE GARAGE AT CELLAR LEVEL | Aug 16, 2023 | Found in violation | — |
| 1602261 | Dec 9, 2022 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL E | Mar 1, 2023 | Found in violation | — |
| 520287 | Oct 8, 2021 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTI | May 11, 2022 | Found in violation | — |
| 1653106 | Aug 18, 2021 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLA | Jan 26, 2022 | Found in violation | — |
| 1578567 | Jul 6, 2021 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.AT TIME OF INSPECTIO | Dec 20, 2021 | Found in violation | — |
| 1349227 | Jun 2, 2021 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT CORNER | Feb 7, 2022 | Found in violation | — |
| 1263728 | Jun 2, 2021 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V | Feb 7, 2022 | Found in violation | — |
| 789097 | Jun 1, 2021 | REPAIR IN-CAR EMERGENCY PHONE., PROVIDE BRAKE TAG DATE IN TH ELEVATOR | Nov 15, 2021 | Found in violation | — |
| 1591521 | Jun 1, 2021 | REPAIR IN-CAR EMERGENCY PHONE., REPAIR CAR STATION EMERGENCY CALL BUTT | Oct 27, 2021 | Settled by stipulation | — |
| 1591519 | Jun 1, 2021 | CLEAN PIT., REPAIR PIT LIGHT., REPAIR IN-CAR EMERGENCY PHONE., CLEAN C | Nov 15, 2021 | Settled by stipulation | — |
| 528832 | Jun 1, 2021 | REPAIR IN-CAR EMERGENCY PHONE., PROVIDE INTERLOCK COVER ON 2ND FLOOR., | Nov 15, 2021 | Found in violation | — |
| 1591520 | Jun 1, 2021 | PROVIDE BRAKE TAG DATE IN THE ELEVATOR MAINTENANCE LOG BOOK., CLEAN PI | Nov 15, 2021 | Settled by stipulation | — |
| 1591522 | Jun 1, 2021 | REPAIR IN-CAR EMERGENCY PHONE., PROVIDE TOP OF CAR HOIST ROPE DATA TAG | Nov 15, 2021 | Settled by stipulation | — |
| 1762032 | Apr 14, 2021 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. FAILURE TO COMPLY W | Oct 8, 2021 | Found in violation | — |
| 1575029 | Apr 14, 2021 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT CORNER OF | Nov 15, 2021 | Found in violation | — |
| 516908 | Nov 24, 2020 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER:AT TIME OF INS | Apr 7, 2021 | Found in violation | — |
| 1447970 | Nov 24, 2020 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:AT TIME OF INSPE | Apr 7, 2021 | Found in violation | — |
| 1513961 | Sep 24, 2020 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONST DOCUMENTS AT JOB SITE TIME | Mar 3, 2021 | Found in violation | — |
| 1131946 | Jul 28, 2020 | AT TIME OF INSPECTION, LOOSE METAL RAILING AT MASONRY WALL AT NORTH EN | May 7, 2021 | Found in violation | — |
| 1301654 | Jun 16, 2020 | BAD CABLES ON THE MACHINE RUSTED AND BROKEN. TRACTION SHEAVE WORN CABL | Oct 21, 2020 | Admitted the violation | — |
| 1573035 | Jun 11, 2020 | BROKEN AND RUSTED CABLE ON THE MACHINE REPLACE (CU). REPLACE CABLE GUA | Oct 14, 2020 | Found in violation | — |
| 938951 | Apr 1, 2020 | JOBSITE FENCE NOT CONSTRUCTED/MAINTAINED PURSUANT TO SUBSECTION.AT TIM | Aug 5, 2020 | Admitted the violation | — |
| 1586508 | Apr 1, 2020 | WORK WITHOUT A PERMIT.AT TIME OF INSPECTION I OBSERVED A CONSTRUCTION | Aug 5, 2020 | Admitted the violation | — |
| 1573007 | May 1, 2019 | 05A10,59BB07,68B07. 05A10-CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEE | Aug 12, 2019 | Found in violation | — |
| 1394051 | Oct 6, 2018 | FAILURE TO OBEY A VACATE ORDER BY THE COMMISSIONER PER 28-207.4: AT TI | Jun 5, 2019 | Defaulted (did not respond) | — |
| 1586563 | Aug 1, 2018 | FAILURE TO FILL ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECT | Jul 1, 2019 | Found in violation | — |
| 1573001 | Jul 18, 2018 | 5A10.67L10.5A10.CEASE USE STEM DOOR ZONE RESTRICTOR HAS BEEN TAMPERED | Sep 25, 2018 | Found in violation | — |
| 244755 | Apr 3, 2018 | *05X10,*59J01,100M07,70O02,17H11,17D06,37Y02,27BB16,42G11,68BB07,14J01 | Jun 4, 2018 | Found in violation | — |
| 1280162 | Oct 23, 2017 | 5A10,59BB7,56Y2,56Y13,68M7. 5A10 CEASE USE ITEM DOOR ZONE RESTRICTOR H | Dec 11, 2017 | Found in violation | — |
| 1181854 | Aug 23, 2016 | 95X10 DOOR ZONE RESTRICTOR HAS BEEN DISABLE. | Dec 28, 2016 | Found in violation | — |
| 119089 | Mar 28, 2016 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION | May 16, 2016 | Admitted the violation | — |
| 1047701 | Dec 3, 2015 | 3310.8.4,NO RECORD IN THE SITE SAFETY LOG BOOK.NOTE:SIDEWALK SHED IN P | May 9, 2016 | Cured | — |
| 1646901 | Oct 6, 2015 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.FAILURE TO MAIN | Nov 23, 2015 | Found in violation | — |
| 1060134 | Oct 6, 2015 | 3314.10.2 PARTIAL SWO FOR SUSPENDED SCAFFOLD ISSUED PURSUANT TO 28-207 | Nov 23, 2015 | Found in violation | — |
| 1075866 | Mar 14, 2014 | 3310.3 SITE SAFETY PLAN AND SITE SAFETY PROGRAM REQUIRED STOP ALL WORK | Apr 28, 2014 | Found in violation | — |
| 815368 | Nov 30, 2011 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTE: AT REAR O | Jan 23, 2012 | Settled by stipulation | — |
| 834952 | Apr 28, 2009 | WORK W/ EXPIRED PERMIT. ILLEGAL WORK NOTED: EXISTING APPLICATIONS ON F | Apr 28, 2010 | Found in violation | — |
| 839766 | Apr 28, 2009 | SIDEWALK SHED DOES NOT MEET CODE & SPECIFICATIONS. DEFECTS NOTED:SHEDS | May 6, 2010 | Found in violation | — |
| 560039 | Apr 28, 2009 | WORK W/O A PERMIT. ILLEGAL WORK NOTED: AT REAR YARD SET BACK SOUTH EAS | Apr 28, 2010 | Found in violation | — |
| 1315768 | Apr 28, 2009 | SECTION 28.502.7.3.6. FAILURE TO ERECT OR EXTEND METAL EXHAUST DUCT SY | May 3, 2010 | Written off | — |
| 580016 | Apr 9, 2009 | INADEQAUTE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN UNSAFE | Jan 26, 2011 | Found in violation | — |
| 1242368 | Mar 18, 2009 | B301.50A.50B 50A WORK W/O A PERMIT 28.105.1 50B NO WORK PERMIT FILED | May 11, 2009 | Written off | — |
| 821140 | Mar 18, 2009 | B301.50A.50B 50A WORK W/O A PERMIT 28.501 50B NO WORK PERMIT FILED W/D | May 11, 2009 | Found in violation | — |
| 784847 | Dec 19, 2008 | FAIL TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT IND | Jun 14, 2010 | Found in violation | — |
| 317721 | Jun 30, 2008 | SEC. 27-1042. NO CERTIFICATE OF FITNESS FOR SCAFFOLD WORKER, 2 WORKERS | Dec 8, 2008 | Found in violation | — |
| 288801 | Nov 9, 2004 | FAILURE TO MAINTAIN HAZARDOUS DEFECT ARE MISSING TWO(2)FIRE RATED DOOR | Jan 10, 2005 | Found in violation | — |
| 461403 | Jun 2, 1999 | 8V,74H. REPLACE CAR AND FIRST FLOOR SADDLE. | Jul 19, 1999 | Defaulted (did not respond) | — |
| 127478 | Oct 19, 1993 | 75U,73U,4M,74X,55X,57O,15Q,46#,21J,74O,74T. 4 MANUAL AND FIVE PIN KEY | Jan 3, 1994 | Found in violation | — |
| 129370 | Oct 19, 1993 | 75U,73U,4M,74O,74X,21J,46#,15Q. 4 MANUAL AND FIVE PIN | Jan 3, 1994 | Found in violation | — |
| 126553 | Oct 19, 1993 | 75U,73U,4M,74O,74X,21J,15Q,463. 4 MANUAL AND FIVE PIN KEY. 74 TOP CAR | Jan 3, 1994 | Found in violation | — |
| 126401 | Oct 19, 1993 | 75U,73U,4M,74O,74X,55X,57O,463,15Q,21J,74T. 4 MANUAL AND FIVE PIN KEY | Jan 3, 1994 | Found in violation | — |
| 127542 | Oct 19, 1993 | 75U,73U,4M,74O,74X,21J,46#,15Q. 4 MANUAL AND FIVE PIN KEY. 74 TOP OF | Jan 3, 1994 | Found in violation | — |
| 127697 | Oct 19, 1993 | 75U,73U,4M,74O,74X,55X,57O,15Q,46K,21J. 4 MANUAL AND FIVE PIN KEY. | Jan 3, 1994 | Found in violation | — |
| 129250 | Oct 19, 1993 | 75U,73U,4M,74O,74X,55X,57O,15Q,46#,21J,74T,50Y. 4 MANUAL AND FIVE PIN | Jan 3, 1994 | Found in violation | — |