Open ViolationsA public record project
/

2302 Morris Avenue, Bronx

HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner

2302 Morris Avenue at a glance

2302 Morris Avenue, Bronx has 0 open city records on file, none of them Class C, and no balance recorded as due on OATH/ECB summonses. The most recent record is dated Jul 9, 2026.

Open Class C
0
Immediately hazardous — click to see them
Open Class B
0
Hazardous — click to see them
Open Class A
0
Non-hazardous — click to see them
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
15
Construction permits filed with DOB
Last activity
Jul 9, 2026
DOB record

Health score for 2302 Morris Avenue

A composite of the public indicators below. How it is scored.

A
Health score · Aug 5, 2026
Scored from all 130 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 2
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 2302 Morris Avenue

130 records on file, every agency interleaved. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 2302 Morris Avenue

No balance is recorded as due across the 27 summonses below, out of $78,610.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 2302 Morris Avenue
1456111Mar 12, 2020FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33Jan 8, 2021Admitted the violation
1456118Mar 12, 2020BC330372-FIRE EXTINGUISHERS SHALL BE PROVIDED IN RECORDANCE WITH NYC FJan 8, 2021Admitted the violation
1425843Sep 17, 2019BC 3303.12 ELEVATOR AND HOISTS DURING CONSTRUCTION. NOTE:AT THE TIME ONov 22, 2019Found in violation
1426259Sep 7, 20193301.1.3MANUFACTUER SPECIFICATIONS.@TIME OF INSP I OOBSERVED @CONST SINov 22, 2019Found in violation
1440377Jul 17, 2019HOUSEKEEPING. NOTE: AT THE TIME OF INSPECTION OF A 8 STY NEW BLDG UNDESep 6, 2019Found in violation
1414320Jul 17, 2019SEC. 3301.2 UNCAPPED REBARS FAILURE TO MAINTAIN. NOTE: AT THE TIME OF Sep 6, 2019Found in violation
1414325Jul 17, 2019SEC. 3301.6 NO DESIGN DRAWING. NOTE: AT THE TIME OF INSPECTION OF A 8 Sep 6, 2019Found in violation
1440378Jul 17, 2019SEC. 3301.6 NO DESIGN DRAWING. NOTE: AT THE TIME OF INSPECTION OF A 8 Sep 6, 2019Found in violation
1437941Jul 17, 2019NO GUARDRAILS. NOTE: AT THE TIME OF INSPECTION OF A 8 STY NEW BLDG UNDSep 6, 2019Found in violation
1403949Jul 17, 2019SEC. 3307.4.3 INADEQUATE BARRIERS FOR VEHICULAR TRAFFIC. NOTE: AT THE Sep 6, 2019Found in violation
1414329Jul 17, 2019SEC. 3314.1 SCAFFOLDING. NOTE: AT THE TIME OF INSPECTION OF A 8 STY NESep 6, 2019Found in violation
1422898Feb 28, 2019CONSTRUCTION SUPERINTENDENT FAIL TO PERFORM DUTIES AS PER RULE. AT THEJul 31, 2019Found in violation
1422897Feb 28, 2019SIDEWALK SHED WHERE REQUIRED. AT THE TIME OF INSPECTION OBSERVED A NEWJul 30, 2019Found in violation
1383296Feb 28, 2019BC 3309.10 ROOF PROTECTION. AT THE TIME OF INSPECTION OBSERVED A NEW BApr 19, 2019Settled by stipulation
1422896Feb 28, 2019BC 3303.4.1.1. SIDEWALK MAINTENANCE. AT THE TIME OF INSPECTION OBSERVEJul 30, 2019Found in violation
1422893Feb 21, 2019GUARDRAILS.AT THE TIME OF INSPECTION OBSERVED INACTIVE JOB SITE .ALSO Jul 29, 2019Found in violation
1422895Feb 21, 20193301.1UNCAPED REBARS FAILURE TO MAINTAIN.AT THE TIME OF INSPECTION OBSJul 30, 2019Found in violation
1422894Feb 21, 2019NO HANDRAILS.AT THE TIME OF INSPECTION OBSERVED INACTIVE JOB SITE ALSOJul 29, 2019Found in violation
1243981Nov 30, 2018BC 3307.2.1 FAILURE TO COMPLY WITH DOT REGULATIONS. AT THE TIME OF MY Feb 8, 2019Found in violation
1365206Oct 29, 2018HANDRAILS. AT THE TIME OF INSPECTION OF AN 8 STORY BUILDING AT 2ND FL Dec 21, 2018Found in violation
1318077Apr 25, 2018UNCAPPED REBARS. AT TIME OF INSPECTION OBSERVED AN ACTIVE CONSTRUCTIONJun 15, 2018Found in violation
762447Apr 25, 2018FAILURE TO COMPLY WITH ASTM C31 STANDARDS FOR CONCRETE CYLINDER TEST SJun 15, 2018Found in violation
1300687Apr 25, 2018BC3301.2 NO GUARDRAILS. AT TIME OF INSPECTION OBSERVED AN ACTIVE CONSTJun 15, 2018Settled by stipulation
751700Apr 25, 201828-104.7.1 ARCHITECTURAL/STRUCTURAL PLANS (NB OR AH) ARE NOT ADEQUATE Jun 15, 2018Settled by stipulation
1285894Apr 25, 2018CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE. AT TIMEJun 15, 2018Found in violation
1593320Nov 25, 2017NO LIGHTS SIDEWALK SHED AT TIME OF INSPECTION I OBSERVED SIDEWALK SHEDJan 19, 2018Resolved
1593312Nov 25, 2017NO LIGHTS SIDEWALK SHED AT TIME OF INSPECTION I OBSERVED SIDEWALK SHEDJan 19, 2018Resolved