Open ViolationsA public record project
/

212 West 93 Street, Manhattan

HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner

212 West 93 Street at a glance

212 West 93 Street, Manhattan has 0 open city records on file, none of them Class C, and no balance recorded as due on OATH/ECB summonses. The most recent record is dated Dec 23, 2025.

Open Class C
0
Immediately hazardous — click to see them
Open Class B
0
Hazardous — click to see them
Open Class A
0
Non-hazardous — click to see them
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
17
Construction permits filed with DOB
Last activity
Dec 23, 2025
Bedbugs record

Health score for 212 West 93 Street

A composite of the public indicators below. How it is scored.

A
Health score · Aug 5, 2026
Scored from all 128 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Record timeline for 212 West 93 Street

128 records on file, every agency interleaved. Class A, B and C are HPD’s hazard tiers: C is immediately hazardous, A and B explained here.

Download this timeline (CSV) →

OATH / ECB summonses & fines at 212 West 93 Street

No balance is recorded as due across the 19 summonses below, out of $30,917.00 in penalties imposed. Balances are as the city publishes them; a settlement or write-off that never reached the dataset will not show here. New to these? How an OATH summons becomes a penalty, explained.

OATH and ECB summonses for 212 West 93 Street
991861Jun 19, 2021FAILED TO NOTIFY DEPARTMENT PRIOR TO INSTALLATION OR REMOVAL OF SUSPENMay 12, 2022Found in violation
1421816Mar 16, 2021BC3314.4 FAILURE TO ERECT & MAINTAIN SUPPORTED SCAFFOLD AS PER CODE.ATJan 6, 2022Found in violation
1420956Dec 22, 2020PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECFICIATIONS. AT TIME OF INJul 15, 2021Found in violation
1420975Dec 22, 2020UNLAWFULLY CONTINUED WORK WHILE WHILE ON NOTICE OF A STOP WORK ORDER. Jul 15, 2021Found in violation
1421590Dec 19, 2020WORK DOES NOT CONFORM NOTE AT THE TIME OF MY INSPECTION OF A 14 STROY Jun 10, 2021Found in violation
1421554Dec 19, 2020BC3301.6-FAILURE TO HAVE DESIGN DRAWING NOTE AT THE TIME OF MY INSEPCTJun 10, 2021Found in violation
1421599Dec 19, 2020BC3307.2-FAILURE TO AINTAIN D.O.T PERIT NOTE AT THE TIME FO MY ISNEPCTJun 10, 2021Found in violation
1353310Dec 19, 2020FAILURE TO INSTITUTE AND MAINTAIN SAFETY MEASURES NOTE AT THE TIME OF Jun 10, 2021Found in violation
1415541Jan 7, 2020FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. AT THE TIME OF INSPECTION OAug 13, 2020Admitted the violation
1151944Jan 7, 2020BC 3314.1 SUPPORTED SCAFFOLD ERECTED NOT AS PER CODE. AT THE TIME OF IAug 13, 2020Admitted the violation
1014851Jan 7, 2020PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. AT THE TIME OFAug 13, 2020Admitted the violation
1480690Jan 7, 2020BC 3308.1 FAILURE TO PROVIDE PROTECTION ON UNENCLOSED PERIMETERS. AT TAug 13, 2020Admitted the violation
1418421Dec 11, 2019BC 3301.6 DESIGN,SIZES,AND CAPACITY OF MATERIALS,STRUCTURES TEMP CONSTJul 2, 2020Found in violation
1386587Oct 31, 2019B3307.1/FAILURE TO PROVIDE SAFETY MEETING AS REQUIRED.NOTE:AT TIME OF Feb 11, 2021Found in violation
1418639Oct 21, 2019FAILURE TO PROVIDE DESIGN DRAWING FOR GENERAL TEMPORALY CONSTRUCTION ENov 19, 2020Found in violation
1418646Oct 21, 2019FAILURE TO MAINTAIN ADAQUATE HOUSEKEEPING PER SECTION REQUIREMENT.AT TNov 19, 2020Found in violation
1418746Oct 21, 2019BC330314-FAILURE TO PROVIDE ADEQUATE DRAINAGE TO PREVENT WATER ACCUMILSep 17, 2020Found in violation
1391504May 9, 2019WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AT TIME OF INJul 11, 2019Found in violation
1427792Jan 15, 2008B4A 50,50A,50B,50C,50D,50E 50 AIR HANDLER IN BOILER RM TAKING AIR OUT Mar 6, 2008Found in violation