| 039182861P | Apr 1, 2026 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Jul 30, 2026 | IN VIOLATION | $1,250.00 |
| 781202 | Apr 1, 2026 | VF... CEASE USED.. HOIST ROPES UNSECURED PROPERLY SECURED...62-D-6.... | Jul 30, 2026 | IN VIOLATION | $1,250.00 |
| 049354825Z | Aug 25, 2025 | FAILURE TO CLEAN 18 INCHES INTO STREET | Nov 24, 2025 | Pending | — |
| 049270977J | Aug 15, 2025 | STORAGE OF RECEPTACLES PLACED OUT PRIOR TO 8PM WITHOUT A RECEPTACLE | Nov 14, 2025 | Pending | — |
| 048806724H | Jan 23, 2025 | FAILURE TO CLEAN 18 INCHES INTO STREET | Apr 25, 2025 | SETTL IN-VIO | — |
| 1733426 | Oct 18, 2023 | HOUSEKEEPING (MAINTANANCE) NOTE: AT TIME OF INSPECTION I OBSERVED THAT | Aug 1, 2024 | IN VIOLATION | $1,250.00 |
| 047174324J | Aug 27, 2021 | FAILURE TO CLEAN 18 INCHES INTO STREET | Nov 26, 2021 | SETTL IN-VIO | — |
| 047001915X | May 26, 2021 | IMPROPER RECEPTACLES 1ST OFFENSE | Aug 24, 2021 | SETTL IN-VIO | — |
| 046999484Z | Mar 24, 2021 | IMPROPER RECEPTACLES 1ST OFFENSE | Jun 22, 2021 | Pending | — |
| 0211528727 | Aug 1, 2020 | IMPROPER RECEPTACLES 1ST OFFENSE | Nov 2, 2020 | Pending | — |
| 0210226601 | Jan 23, 2020 | FAILURE TO CLEAN 18 INCHES INTO STREET | Apr 20, 2020 | Pending | — |
| 0205849041 | Jan 24, 2019 | IMPROPER RECEPTACLES 1ST OFFENSE | Mar 4, 2019 | Pending | — |
| 037012536R | Nov 20, 2018 | FAIL TO COMPLY W COMMISSIONER ORDER TO FILE CERT OF CORRECTION W DOB | Apr 18, 2019 | DEFAULTED | — |
| 660500 | Nov 20, 2018 | FAILURE TO COMPLY W/ COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATI | Apr 18, 2019 | DEFAULT | — |
| 1313659 | Jan 30, 2018 | 56Y13,59BB7,70O2,71M7,44H8. 56Y13-HOIST MOTOR OIL LEAK SEAL; 59BB7-MA | Mar 22, 2018 | STIPULATION/IN-VIO | — |
| 038260818Y | Jan 30, 2018 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Mar 22, 2018 | STIPULATED | — |
| 038259879J | Dec 5, 2017 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Jan 25, 2018 | STIPULATED | — |
| 1156811 | Dec 5, 2017 | 97X10/97-X-10;RESTORE TO SERVICE IMMEDIATELY AS PER CODE IRCNY NYC DOB | Jan 25, 2018 | STIPULATION/IN-VIO | — |
| 038252217Z | Jan 9, 2017 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Feb 23, 2017 | DEFAULTED | — |
| 608373 | Jan 9, 2017 | 97X17. UPON INSP THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A H | Feb 23, 2017 | DEFAULT | — |
| 038251151K | Dec 13, 2016 | FAILURE TO MAINTAIN ELEVATOR OR CONVEYING SYSTEM | Feb 2, 2017 | IN VIOLATION | — |
| 1325837 | Dec 13, 2016 | 97X10 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, SERVICE | Feb 2, 2017 | IN VIOLATION | — |
| 035134031Y | Mar 17, 2016 | REMOVAL OF SHED OR PROTECTIVE MEASURE WITHOUT DEPARTMENT APPROVAL | May 5, 2016 | DEFAULTED | — |
| 1446976 | Mar 17, 2016 | REMOVAL OF SIDEWALK SHED W/O DEPARTMENT'S APPROVAL. NOTED AT TIME OF I | May 5, 2016 | DEFAULT | — |
| 043556557Z | Feb 18, 2016 | NON-RECYCLABLES IN RECYC. CONTAINER FOR COLLECTION 9+ DWELLING UNTS | Mar 21, 2016 | Pending | — |
| 043329472J | Jan 21, 2016 | RECYCLABLES PLACED FOR COLLECTION W NON-RECYCL 9+ DWELLING UNITS | Feb 22, 2016 | DEFAULT | — |
| 035133979Y | Jan 15, 2016 | FAILURE TO MAINTAIN BUILDING WALL S OR APPURTENANCES | Mar 10, 2016 | IN VIOLATION | — |
| 960519 | Jan 15, 2016 | FAILURE TO PROVIDE SAFETY MEASURE/SIDEWALK SHED, NETTING,ETC. WHERE RE | Mar 10, 2016 | IN VIOLATION | — |
| 035133980L | Jan 15, 2016 | REMOVAL OF SHED OR PROTECTIVE MEASURE WITHOUT DEPARTMENT APPROVAL | Mar 10, 2016 | IN VIOLATION | — |
| 925537 | Jan 15, 2016 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE AND APPURTENANCES. NOTE:NORTH | Mar 10, 2016 | IN VIOLATION | — |
| 488018 | Jan 15, 2016 | REMOVAL OF SIDEWALK SHED W/O DEPT'S APPROVAL.NOTED: AT TIME OF INSPECT | Mar 10, 2016 | IN VIOLATION | — |
| 035133981N | Jan 15, 2016 | FAIL TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFWTY-UNSAFE FACADE | Mar 10, 2016 | IN VIOLATION | — |
| 600872 | Dec 11, 2015 | FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDI | May 12, 2016 | DEFAULT | — |
| 959945 | Oct 9, 2015 | FAILURE TO PROVIDE SIDEWALK SHED OR OTHER TYPE OF SAFETY MEASURE TO | Dec 10, 2015 | IN VIOLATION | — |
| 035133716M | Oct 9, 2015 | FAIL TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFWTY-UNSAFE FACADE | Dec 10, 2015 | IN VIOLATION | — |
| 044460131L | Aug 25, 2015 | RECYCLABLES PLACED FOR COLLECTION W NON-RECYCL 9+ DWELLING UNITS | Sep 25, 2015 | DEFAULT | — |
| 0186113328 | Jan 29, 2015 | IMPROPER DISPOSAL BEDDING 1ST OFFENSE | Mar 2, 2015 | DEFAULTED | — |
| 1080982 | Dec 9, 2014 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICAIONS.NOTED:SHED EREC | Jan 29, 2015 | IN VIOLATION | — |
| 035150100Z | Dec 9, 2014 | PEDESTRAIN PROTECTION DOES NOT MEET CODE SPECIFICATIONS | Jan 29, 2015 | IN VIOLATION | — |
| 973370 | Nov 26, 2014 | PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT 28-207.2 & POSTED O | Feb 26, 2015 | IN VIOLATION | — |
| 035100915Y | Nov 26, 2014 | FAIL NOTIFY DEPT OBTAIN PERMIT PRIOR TO USE INST OFF C-HOOK OUTRIGGER | Feb 26, 2015 | IN VIOLATION | — |
| 725444 | Nov 25, 2014 | SIDEWALK SHED PARAPET SIGN PANEL IS NOT PROVIDED.NOTED:@ TIME OF INSP | Apr 9, 2015 | IN VIOLATION | — |
| 035100910P | Nov 25, 2014 | SIGN PANEL NOT PROVIDED OR NOT INCOMPLIANCE WITH SECTION | Apr 9, 2015 | IN VIOLATION | — |
| 040109713H | Sep 20, 2014 | RECYCLABLES PLACED FOR COLLECTION WITH NON-RECYC 9+ DWELLING UNITS | Oct 21, 2014 | DEFAULT | — |
| 035015101Z | May 13, 2013 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS | Jun 27, 2013 | DEFAULTED | $10,000.00 |
| 893573 | May 13, 2013 | SIDEWALK SHED DOES NOT CONFORM/MEET CODE SPECIFICATIONS DEFECT NOTED: | Jun 27, 2013 | WRITTEN OFF | — |
| 785255 | Feb 2, 2009 | 60B07.100L10.69M07.60B07 MOTOR RM LIGHTING IS INSUFFICIENT PROVIDE 100 | Sep 24, 2009 | IN VIOLATION | — |
| 0159417812 | Nov 30, 2007 | FAILURE TO PROPERLY PUT RECYCLABLES OUT FOR COLLECTION | Jan 22, 2008 | WRITTEN OFF | — |
| 754878 | Nov 15, 2007 | Elevators | Aug 21, 2008 | IN VIOLATION | — |
| 038168777P | Aug 2, 2007 | FILING A FALSE CERTIFICATE,FORM,AFFIDAVIT,STATEMENT WITH BLDG. DEPT | Apr 24, 2008 | IN VIOLATION | — |
| 754865 | Aug 2, 2007 | FILING A FALSE CERTIFICATION W/ THE N.Y.C DEPT OF BLDG PURSUANT TO SEC | Apr 24, 2008 | IN VIOLATION | — |
| 455271 | Aug 2, 2007 | 61I10,55Y10,55O02,58I/M10,40T07,43O02,39M07,38O02.61I10-REPAIR COMMUTA | Dec 20, 2007 | IN VIOLATION | — |
| 038168779Z | Aug 2, 2007 | FAILURE TO MAINTAIN ELEVATOR | Dec 20, 2007 | IN VIOLATION | — |
| 453332 | Apr 17, 2007 | 83**,83X10.83**-DEVICE #1V20806 FILED UNDER EA 71-02 HAS HAD NO TEST.I | Jun 14, 2007 | IN VIOLATION | — |
| 576875 | Nov 3, 2006 | 83:DEVICE# 1V20806 FILED UNDER EA 71-02 HAS HAD NO TEST. IF DEVICE WAS | Mar 8, 2007 | IN VIOLATION | — |
| 143170 | Jun 3, 2002 | 50B11. REPAIR HOIST MOTOR COMMUTATOR. PROPERLY SPREAD BREAK COTTER PIN | Jul 18, 2002 | IN VIOLATION | — |
| 289981 | Apr 26, 2000 | 50Y2,50Y14,50#9,57O2. 50- NOISE AND LOST MOTION. | Aug 3, 2000 | IN VIOLATION | — |
| 289985 | Apr 26, 2000 | 57O2,50Y2,30O2,11Q3. | Aug 3, 2000 | IN VIOLATION | — |
| 139736 | Apr 18, 1998 | 30O,28D,30Z,35H,50Y,50Y,35H,73U,57O,60L,47H,46H,2M,46K,60D, 40-C.W. LA | Jun 11, 1998 | WRITTEN OFF | — |
| 68892 | Sep 23, 1992 | 500,37#,53A, 37 RELAY SHUNTS. 53. PROPER WIRING AND RECEPTACLES.. | Dec 3, 1992 | CURED/IN-VIO | — |
| 68955 | Sep 23, 1992 | 11Q,22D,50O,37#, 37 RELAY SHUNTS. | Dec 3, 1992 | STIPULATION/IN-VIO | — |