| 1782591 | May 6, 2026 | WORK WITH A PERMIT. NOTED: AT APT 3C ERECTED FULL HEIGHT PARTITION WAL | Jul 14, 2026 | PENDING | $250.00 |
| 1633178 | Dec 11, 2025 | DOOR ZONE RESTRICTOR NOT WORKING. C/U. REPAIR. TOC SHACKELS MISSING CO | Feb 17, 2026 | IN VIOLATION | $1,250.00 |
| 1630244 | Dec 5, 2025 | ENTIRE DEVICE OUT OF SERVICE RESTORE TO SERVICE | Feb 10, 2026 | IN VIOLATION | $1,250.00 |
| 1503307 | Oct 3, 2025 | CLASS1: THE ELEVATOR IN BUILDING OUT OF SERVICE. UPON INSPECTION, THE | Dec 9, 2025 | IN VIOLATION | $3,125.00 |
| 1502871 | Oct 3, 2025 | CLASS2: THE REQUIRED SIGNS "IN CASE OF FIRE DON'T USE ELEVATOR, USE ST | Dec 9, 2025 | IN VIOLATION | $625.00 |
| 1495557 | Sep 25, 2025 | THE ELEVATOR IN BUILDING OUT OR SERVIVE . UPON INSPECTION THE DEVICE I | Dec 2, 2025 | IN VIOLATION | $1,250.00 |
| 1734676 | Oct 1, 2024 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION R | Feb 11, 2025 | IN VIOLATION | $2,500.00 |
| 1582329 | Dec 2, 2022 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE9A REPORT OF CRITICAL EXAM | Feb 21, 2023 | IN VIOLATION | $1,250.00 |
| 1543194 | Mar 24, 2021 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSP | May 25, 2021 | IN VIOLATION | — |
| 1543196 | Mar 24, 2021 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF A SYSTE | May 25, 2021 | IN VIOLATION | — |
| 494657 | Oct 29, 2015 | PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD AND FACADE JOB ISSUED P | Feb 9, 2016 | IN VIOLATION | — |
| 494555 | Oct 29, 2015 | PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD ISSUED PURSUANT TO 28- | Feb 9, 2016 | CURED/IN-VIO | — |
| 494533 | Oct 29, 2015 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION | Feb 9, 2016 | IN VIOLATION | — |
| 277108 | Oct 28, 2015 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION O | Mar 1, 2016 | IN VIOLATION | — |
| 1082758 | Jun 2, 2015 | PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD & ALL WORKS AT ROOF LEV | Jul 21, 2015 | IN VIOLATION | — |
| 1082776 | Jun 2, 2015 | SEC. 3314.15.2 PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD ISSUED P | Jul 21, 2015 | IN VIOLATION | — |
| 982438 | Dec 10, 2014 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.DEFECT NOTED:@ 1 STY | Jul 21, 2015 | IN VIOLATION | — |
| 1240437 | Dec 17, 2013 | 58H10,59H11. 58H10-LOUD NOISE FROM WORM AND GEAR. | Feb 4, 2014 | ADMIT/IN-VIO | — |
| 489496 | Oct 31, 2011 | 77B11,72M07,56Y02 77-PROVIDE SIZE TOE GUARD 3.3.2 K3 | Dec 20, 2011 | STIPULATION/IN-VIO | — |
| 778536 | Oct 31, 2011 | 77B11,72M07,42G11,40Q02 77-PROVIDE PROPER SIZE TOE GUARD 3.3.2 K3 | Dec 20, 2011 | STIPULATION/IN-VIO | — |
| 37929 | Sep 22, 2006 | 08V01, 16B01. 08V EVERY FL- CAR NOT LEVEL W/ SILL. 16F- BASEMENT & LOB | Nov 14, 2006 | IN VIOLATION | — |
| 95526 | Apr 28, 1994 | 15L,50Y, #15 4TH FLOOR DOOR CRACK (DOOR SLAMING) | Jun 14, 1994 | IN VIOLATION | — |