| 1448531 | Oct 9, 2025 | WORK WITHOUT PERMIT. NOTED: ILLUMINATED SIGN APPROX: 20'X3' INSTALLED | Dec 19, 2025 | IN VIOLATION | — |
| 77060 | Aug 6, 2025 | AGG 2 VIOLATION ISSUED, UPON INSPECTION OF DEVICE, NO DLM WAS FOUND ON | Sep 25, 2026 | Resolved | $6,250.00 |
| 1589552 | Feb 6, 2025 | ACCESS TO THE HEATING SYSTEM SHALL BE READILY PROVIDED TO THE DEPT. AS | Jul 18, 2025 | IN VIOLATION | — |
| 1441489 | Dec 30, 2024 | CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEA | Mar 7, 2025 | IN VIOLATION | — |
| 1438700 | Jun 24, 2024 | CEASE USE ITEM: ZERO CLEARANCE BETWEEN SADDLE AND SILL. SADDLE HITTING | Aug 30, 2024 | IN VIOLATION | — |
| 1407041 | May 21, 2024 | 05-A-10, 69-M-67, 100-N-10, 1-D-06, 67-X-10, 42-M-07. RESPONDING TO A | Aug 2, 2024 | IN VIOLATION | — |
| 1428480 | Mar 8, 2024 | RESPONDING TO A 311 ELEVATOR COMPLAINT,UPON INSPECTION ON THE ONLY DEV | May 17, 2024 | IN VIOLATION | — |
| 1426577 | Nov 6, 2023 | RESPONDING ON A SCHEDULED RESTORE TO SERVICE RE-INSPECTION, NO ONE WAS | May 24, 2024 | IN VIOLATION | — |
| 1426406 | Oct 26, 2023 | RESPONDING TO A 311 ELEVATOR COMPLAINT. UPON INSPECTION OF DEVICE, CEA | Jan 5, 2024 | IN VIOLATION | — |
| 1407015 | Sep 8, 2023 | 42-M-5AGGII,97-X-17,42-N-11,2-X-10. AGGRAVATED II CONDITION. RESPONDEN | Nov 17, 2023 | IN VIOLATION | — |
| 1423154 | Aug 22, 2023 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO | Dec 1, 2023 | IN VIOLATION | — |
| 1824559 | Aug 22, 2023 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO | Dec 1, 2023 | IN VIOLATION | — |
| 1421471 | Aug 10, 2023 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO | Nov 3, 2023 | IN VIOLATION | — |
| 1406899 | Jun 23, 2023 | 42M7 AND 2X10 NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS | Sep 1, 2023 | IN VIOLATION | — |
| 1413933 | Mar 30, 2023 | RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION OF DEVICE VIOL | Jun 16, 2023 | IN VIOLATION | — |
| 1634573 | Sep 21, 2022 | CLASS 1 VIOLATION ISSUED NO DLM INSTALLED IN THIS CONTROLLER. NO DOOR | Dec 16, 2022 | IN VIOLATION | — |
| 1634534 | Jul 26, 2022 | CLASS 1 VIOLATION ISSUED NO DOOR LOCK MONITORING INSTALLED IN THIS CON | Sep 16, 2022 | IN VIOLATION | — |
| 1355990 | May 12, 2020 | 42-L-10,59-BB-5=42-CAR BY PASSES FLOOR CALLS SOMETIMES:REMEDY REPAIR S | Oct 2, 2020 | IN VIOLATION | — |
| 1589557 | Aug 8, 2018 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35336381 | Nov 9, 2018 | IN VIOLATION | — |
| 1650993 | Jun 30, 2018 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT REAR | Nov 16, 2018 | IN VIOLATION | — |
| 1096702 | May 9, 2018 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V | Oct 12, 2018 | IN VIOLATION | — |
| 630226 | Apr 19, 2018 | CU-05A10; 39O02,70O02,80M07,71X10,03D06,67X10,41M07,44M03,41O02,68B01, | Jun 15, 2018 | IN VIOLATION | — |
| 455983 | Apr 4, 2018 | 15,32A-15)OPENING IN WALLS/CEILING. 32)WIRING EXPOSED. CORRECT ALL VIO | Jun 1, 2018 | CURED/IN-VIO | — |
| 1650970 | Mar 19, 2018 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: REAR OF | Aug 24, 2018 | IN VIOLATION | — |
| 572230 | Nov 15, 2017 | FGC 401.1 GAS PIPING NOT LABELED OBSERVED ON 11//15/2017 @ABOVE ADDRES | Mar 9, 2018 | IN VIOLATION | — |
| 571894 | Nov 15, 2017 | FAILURE TO PROVIDE ADEQUATE GROUNDING TO ELECTRICAL SYSTEMS. OBSERVED | Mar 9, 2018 | IN VIOLATION | — |
| 1350017 | Nov 15, 2017 | FAILURE TO PROVIDE GROUND FAULT CIRCUIT INTERRUPTOR(GFCI)PROTECTION AS | Mar 9, 2018 | IN VIOLATION | — |
| 1536665 | Nov 15, 2017 | FAILUR ETO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:LACK OF EMERGENCY L | Mar 9, 2018 | IN VIOLATION | — |
| 1286876 | Nov 15, 2017 | SEC. 250.68 WATER MAIN GROUND CLAMP NOT ACCESSIBLE. OBSERVED IN BASEME | Mar 9, 2018 | STIPULATION/IN-VIO | — |
| 572115 | Nov 15, 2017 | SEC. 430.75 NO MOROE DISCONNECT PROVIDED. OBSERVED ON ROOF AREA KITCHE | Mar 9, 2018 | IN VIOLATION | — |
| 571522 | Nov 15, 2017 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIAL APPARATUS,D | Mar 9, 2018 | IN VIOLATION | — |
| 1239584 | Nov 15, 2017 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTE:LAUNDRY/ON THE | Mar 9, 2018 | STIPULATION/IN-VIO | — |
| 1468753 | May 9, 2017 | B180,1,FGC408.2.DRIP-FUTURE CONNECTIONS EXIST DOWN STRAM OF APPLIANCES | Oct 6, 2017 | IN VIOLATION | — |
| 559715 | May 9, 2017 | B180,1,FGC401.1. GAS PIPING NOT LABELED.OBSERVED ON 5/9/17 GAS PIPING | Oct 6, 2017 | IN VIOLATION | — |
| 559099 | May 9, 2017 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF EMERGENCY L | Oct 6, 2017 | IN VIOLATION | — |
| 1193707 | Jan 25, 2017 | 59T15,68B7,40T15,2B7,8V1,39O2,70O2. 40-UNLABELED MOTOR ROOM DOOR; 2-N | Jun 9, 2017 | STIPULATION/IN-VIO | — |
| 1472874 | Nov 23, 2016 | SEC. 408.2 MISC VIOLATION DRIPS-FUTURE CONNECTS EXIT DOWN STREAM OF AP | Jun 23, 2017 | IN VIOLATION | — |
| 720993 | Oct 17, 2016 | WORK W/O A PERMIT. AT THE TIME 2PM OF MY INSPECTION ON 10-17-16 AT THE | Apr 7, 2017 | IN VIOLATION | — |
| 1650933 | Oct 17, 2016 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. AT THE TIME 2PM | Apr 7, 2017 | IN VIOLATION | — |
| 1302146 | May 27, 2016 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.ILLUMINATION FOR EXI | Jan 20, 2017 | IN VIOLATION | — |
| 784897 | Jun 12, 2015 | 8V1,3I10,42G11,68U7. 3-PHONE NOT WORKING. | Sep 11, 2015 | WRITTEN OFF | — |
| 905251 | Sep 14, 2011 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLAINT MANNER. NOTED: AT NOR | Nov 4, 2011 | DEFAULT | — |
| 713506 | Oct 13, 2007 | SEC. ZR 23-44. NOT A PERMITTED OBSTRUCTION IN SIDE YARD AC UNIT INSTAL | Jan 25, 2008 | IN VIOLATION | — |
| 1008867 | Oct 28, 2005 | WORK W/O A PERMIT. WORK NOTED: 3 METAL CHIMNEYS INSTALLED AT THE EAST | Feb 24, 2006 | IN VIOLATION | — |
| 497700 | Aug 12, 2000 | 01L12 02L12 03I11 05L11 08V01 15L11 18K12 21K12 28L11 32M07 35O02 57O0 | Mar 5, 2001 | DEFAULT | — |