| 751860 | Jul 22, 2026 | AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWAL | Oct 2, 2026 | PENDING | $2,400.00 |
| 751893 | Jul 22, 2026 | AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWAL | Oct 2, 2026 | PENDING | $1,250.00 |
| 1818395 | May 1, 2026 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIME OF | Jul 31, 2026 | PENDING | $2,500.00 |
| 1818394 | May 1, 2026 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF IN | Jul 31, 2026 | PENDING | $6,250.00 |
| 1818396 | May 1, 2026 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Jul 31, 2026 | PENDING | $1,250.00 |
| 1818397 | May 1, 2026 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIME OF | Jul 31, 2026 | PENDING | $2,500.00 |
| 1818417 | May 1, 2026 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Jul 31, 2026 | PENDING | $1,250.00 |
| 1818412 | May 1, 2026 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Jul 31, 2026 | PENDING | $1,250.00 |
| 1818423 | May 1, 2026 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Jul 31, 2026 | PENDING | $1,250.00 |
| 1818398 | May 1, 2026 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Jul 31, 2026 | PENDING | $1,250.00 |
| 1818393 | May 1, 2026 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Jul 31, 2026 | PENDING | $1,250.00 |
| 1798922 | Jan 7, 2026 | CLASS 2 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UP | Mar 20, 2026 | IN VIOLATION | $312.00 |
| 1810327 | Aug 13, 2025 | CLASS 2 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SER | Sep 28, 2026 | PENDING | $3,125.00 |
| 1724010 | Jul 31, 2025 | ROOM1 GAS METER INFRONT OF SUPER APT MADE INTO A BEDROOM, WITH SINK AN | Sep 14, 2026 | PENDING | $25,000.00 |
| 1723996 | Jul 31, 2025 | INSIDE ELECTRICAL FUSE BOX INSIDE LAUNDRY ROOM FUSES IS BEING JUMPED W | Sep 14, 2026 | PENDING | $12,500.00 |
| 1724004 | Jul 31, 2025 | CELLAR LEVEL IN ALL ROOM FIRESTOP NOT DONE, FOAM USED IN SOME ROOMS AN | Sep 14, 2026 | PENDING | $12,500.00 |
| 1724039 | Jul 31, 2025 | ROOM4 STORAGE/WORKSHOP ROOM FAR CORNER OF BUILDING TURNED INTO APT WIT | Sep 14, 2026 | PENDING | $25,000.00 |
| 1733901 | Jul 31, 2025 | ROOM2 2ND GAS METER ROOM AT END OF HALL, TURNED INTO LIVING ROOM AREA | Oct 14, 2026 | PENDING | $25,000.00 |
| 1724016 | Jul 31, 2025 | LARGE AND SMALL STORAGE ROOMS HAS INSERTED NEW WATER LINES FOR THE KIT | Sep 25, 2026 | PENDING | $12,500.00 |
| 1724021 | Jul 31, 2025 | ROOM3 END OF HALLWAY OUTSIDE OF LAUNDRY ROOM A ONE BEDROOM APT MADE WI | Sep 14, 2026 | PENDING | $15,000.00 |
| 1733900 | Jul 31, 2025 | FULL HEIGHT PARTITIONS HAS BEEN ERECTED FOR THE BATHROOMS LOCATED AT L | Oct 14, 2026 | PENDING | $12,500.00 |
| 1308302 | Jul 30, 2025 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE | Jan 23, 2026 | IN VIOLATION | $1,250.00 |
| 1226884 | Jul 30, 2025 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE | Oct 3, 2025 | IN VIOLATION | — |
| 1189737 | Jul 14, 2025 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT T | Sep 19, 2025 | IN VIOLATION | — |
| 1217376 | Apr 10, 2025 | AT TIME OF INSPECTION OBSERVED, STEP CRACKS, MISSING/SPALLING MORTAR J | Jun 20, 2025 | IN VIOLATION | — |
| 1723564 | Mar 18, 2025 | WORK WITHOUT A PERMIT. I OBSERVED APARTMENT #1B ILLEGALLY CONVERTED FR | Sep 18, 2026 | PENDING | $1,250.00 |
| 1213642 | Feb 6, 2025 | CLASS 1 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. S | Jul 18, 2025 | IN VIOLATION | — |
| 1213677 | Feb 6, 2025 | CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEA | Jul 18, 2025 | IN VIOLATION | — |
| 1203654 | Aug 21, 2023 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO | Nov 17, 2023 | IN VIOLATION | — |
| 1203771 | Aug 21, 2023 | FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO | Nov 17, 2023 | IN VIOLATION | — |
| 1203024 | Jun 26, 2023 | CEASE USE ITEM: ZONE RESTRICTOR TAMPERED WITH AND INOPERATIVE, REPAIR | Sep 1, 2023 | IN VIOLATION | — |
| 1203013 | Jun 26, 2023 | IN CAR COMMUNICATION INOPERATIVE, REPAIR. IN CAR ALARM INOPERATIVE, RE | Sep 1, 2023 | IN VIOLATION | — |
| 1681725 | Sep 22, 2021 | 5L10,42M5,59BB5,24L10:5-L-10=DEFECTIVE DOOR ZONE RESTRICTOR MUST REPAI | Feb 4, 2022 | IN VIOLATION | — |
| 1681726 | Sep 22, 2021 | 42M5,59BB5:42-M-5=DOOR LOCK MONITORING NOT INSTALLED ON THIS CONTROLLE | Feb 4, 2022 | IN VIOLATION | — |
| 1091135 | Jul 7, 2020 | CLASS 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER REMEDY; F | Nov 20, 2020 | IN VIOLATION | — |
| 1091132 | Jul 7, 2020 | CLASS 1 NO DOOR LOCK MONITORING IN THIS CONTROLLER AS MANDATED BY 3.10 | Sep 18, 2020 | IN VIOLATION | — |
| 1523214 | Jan 21, 2015 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTANANCES. NOTED: AT ROOF LEVEL | Aug 7, 2015 | IN VIOLATION | — |
| 1253642 | Jan 6, 2015 | 40Q03,56Y13,67X10,68B07,71X10,71Q03. 40Q03-INSTALL COVER FOR ELECTRICA | Feb 20, 2015 | IN VIOLATION | — |
| 2274 | Jan 6, 2015 | 67X10,68B07,71X10,71Q03. 67X10-REPAIR COMMUNICATION IN CAR (TELEPHONE) | Feb 20, 2015 | STIPULATION/IN-VIO | — |
| 267786 | Jul 23, 1990 | OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY #52162 | Oct 12, 1990 | DEFAULT | — |
| 893492 | Jun 10, 1988 | SUPERIVISION OR USE OF RIGGING EQUIPMENT WITHOUT SPECIAL RIGGUS LICENS | Jul 29, 1988 | WRITTEN OFF | — |