OpenViolations
/

4141 Broadway

ManhattanBIN 1063514
3 open Class CHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
3
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
2
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
32
DOB permit records
Last activity
Dec 4, 2025
Bedbugs record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

C
Health score · Jul 29, 2026
Scored from the 300 most recent of 485 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 3
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 3
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Records from every agency, interleaved. Showing the 300 most recent of 485 records on file; the CSV below has the full history.

Download this timeline (CSV) →
Dec 4, 2025
Nov 3, 2025
Nov 3, 2025
Nov 3, 2025
Oct 31, 2025
Oct 30, 2025
Aug 19, 2025
Dec 16, 2024
Sep 18, 2024
Sep 18, 2024
Apr 22, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Apr 1, 2024
Jan 25, 2024
Jan 24, 2024
Jan 22, 2024
Dec 30, 2023
Dec 20, 2023
Dec 12, 2023
Dec 2, 2023
Oct 10, 2023

OATH / ECB summonses & fines

No balance is recorded as due across the 32 summonses below, out of $46,415.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 4141 Broadway
1121964Nov 3, 2025I OBSERVED 100 AMP PANEL INSTALLED OUTSIDE BOILER ROOM WITHOUT AN ELECJan 8, 2026IN VIOLATION
1809894Nov 3, 2025I OBSERVED EXTENSION CORD SPLICE FROM OUTDOOR BOX AND BEEN USED AS PERJan 8, 2026IN VIOLATION
1774855Nov 3, 2025I OBSERVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT, IN BOILERS DISCONNEJan 8, 2026IN VIOLATION
1571881Feb 2, 20222/X/10 OUT SIDE COMM INOPERATIVE REPAIR,16/I/10 HOISTWAY DOOR IN BASEMMay 26, 2022IN VIOLATION
1589922Oct 27, 2020FAILURE TO MAINTAIN EXTERIOR BLDG FACADE AND APPURTENANCES.NOTE:EXPO#1Jan 14, 2021IN VIOLATION
969946Oct 27, 2020FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CJan 14, 2021IN VIOLATION
1538800Sep 4, 2020FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE Apr 8, 2021IN VIOLATION
1343569Feb 29, 2020FAILURE TO TAKE REQUIRED MEASURES TO PROTECT PUBLIC FROM DOCUMENTED UNApr 1, 2021IN VIOLATION
1470542Feb 13, 2020FAILURE TO SUBMIT A REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION Oct 29, 2020IN VIOLATION
1291484Aug 15, 2017210,40M7,40M7. 2X10-OUTSIDE COMM INOPERATIVE REPAIR; 40M7-WHEEL-HOUSEOct 5, 2017STIPULATION/IN-VIO
892002Jul 25, 2017CU-21J01,11X10,23X10,CU16B07. 21J-2ND FLOOR INTERLOCK WHEN ELEVATOR Sep 14, 2017IN VIOLATION
925628Jul 16, 2015PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIALNov 12, 2015IN VIOLATION
1350461Jul 16, 2015OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O #10331954 ILLEGAL OCCUPANCY.Nov 6, 2015IN VIOLATION
667976Jul 16, 2015SEC. 907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE. RNov 6, 2015IN VIOLATION
667917Jul 16, 2015FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER FAILURE TO PROVIDE #Nov 6, 2015IN VIOLATION
667878Jul 16, 2015FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. LACK OF A SYSTEM OFNov 6, 2015IN VIOLATION
1092295Jul 16, 2015WORK W/O PERMIT. WORK NOTED: INSTALL WATER,WASTE & GAS LINES TO FOR 20Feb 25, 2016IN VIOLATION
1471337Dec 13, 2011SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. SHED IS MISSING HORIZFeb 2, 2012WRITTEN OFF
796786Nov 18, 2010SDWLK SHED DOES NOT MEET DOB CODE SPECIFICATIONS.MISSING PARAPET PANELJan 13, 2011DEFAULT
1560822May 22, 2009FAILURE TO MAINTAIN EXTERIOR WALL. DEFECTS NOTED: BLDG HAVING AT 1 EASOct 9, 2009IN VIOLATION
766805Jun 11, 2008B4B5050A50B. 50 SMOKE PIPE ROTTED THUS FUMES ESCAPING 50A MEN WERE CLEJan 29, 2009IN VIOLATION
936576Jun 4, 200821-127 B4B, 51, 32, 40, 50, 50A, 50B, 50C, 50D, 50E 50 SMOKE PIPE ROTTJul 24, 2008IN VIOLATION
1266124Jan 18, 200836P16,55Y13,59R03,60T07,71Q03,71K11,86M05,60T07-PROVIDE COMPANY STICKEMar 13, 2008IN VIOLATION
1334258Nov 5, 20038J1,3X10,14L1,15M7,16L10,28D6,30Q3,36J10,55Y13,57H10,66O02,85U5.3X10-CDec 18, 2003STIPULATION/IN-VIO
1310765Dec 10, 20026Q3-22X11-32D6-52#11. 6-MISSING COVER FOR CAR DOOR MOTOR CONTACT 22-INNov 13, 2003STIPULATION/IN-VIO
721628Mar 26, 2002APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABEL FOR INSPECTION. NOTED: Jul 25, 2002IN VIOLATION
739814Mar 26, 2002PLACE OF ASSEMBLY WXIT SIGN DOES NOT MEET BLDG CODE STANDARS NOTE: AMEJul 25, 2002IN VIOLATION
857152Mar 26, 2002OPERATION OF PLACE OF ACCEMBLY WITHOUT A CURRENT P.A. WITH 140 MOBILE Aug 22, 2002IN VIOLATION
739803Mar 26, 2002FAILURE TO PROVIDE AT LEAST TWO MEANS OF EGREESS. NOTED RESTAURANT KNONov 14, 2002IN VIOLATION
122447Nov 18, 199401I,03M,11Q,15M,18#,25Q,31D,21L,27X,33W,33H,35R,40L,46R,30Q,570, 03M- Dec 22, 1994WRITTEN OFF
72278Dec 28, 199311Q,21L,33W,33O,25Q,31D,35P,7L,73X. 31 TOP CAR. 73 RESTORE TO SERVICE May 12, 1994IN VIOLATION
62276Sep 10, 199117M,73#,22W,11Q,17L,36R. 73#PERFORM 5 YR.TEST AND FILE TAG GOVERNOR. Dec 12, 1991DEFAULT