OpenViolations
/

34-11 Beach Channel Drive

QueensBIN 4615090
$9,375.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
1
Hazardous
Open Class A
0
Non-hazardous
Fines due
$9,375.00
Balance on OATH/ECB summonses
Permits on file
41
DOB permit records
Last activity
Jun 4, 2026
HPD record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

B
Health score · Jul 29, 2026
Scored from all 133 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 1
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $9,375
Bedbug filings with infestations
Annual LL69 filings on record
This building 3
Tenant litigation
Open HP actions in Housing Court
This building 1
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 133 records on file.

Download this timeline (CSV) →
Jun 4, 2026
May 18, 2026
May 18, 2026
Dec 3, 2025
Mar 3, 2025
Jan 27, 2025
Jan 15, 2025
Dec 23, 2024
Dec 6, 2024
Nov 26, 2024
Nov 21, 2024
Nov 6, 2024
Oct 29, 2024
Oct 15, 2024
Oct 10, 2024
Oct 7, 2024
Aug 21, 2024
Aug 15, 2024
Aug 9, 2024
Aug 8, 2024
Aug 7, 2024
Aug 6, 2024
Jul 29, 2024
Jul 28, 2024
Jul 27, 2024
Jul 27, 2024
Jul 27, 2024
Jul 26, 2024
Jun 27, 2024
Jun 15, 2024

OATH / ECB summonses & fines

$9,375.00 is recorded as due across the 16 summonses below, out of $22,962.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 34-11 Beach Channel Drive
1790818Jan 27, 2025THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE.Dec 11, 2026Resolved$3,125.00
1653899Nov 21, 2024THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE.Aug 6, 2026Resolved$3,125.00
1772545Oct 10, 2024: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVADec 17, 2024IN VIOLATION
1772233Aug 21, 2024THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE.Dec 3, 2024IN VIOLATION
1475347Jun 27, 2024ONLY ELEVATOR INTHE SECTION OF BUILDING OUT OF SERVICE. RESTORED TO SENov 25, 2025DEFAULT$3,125.00
1535242Apr 9, 202128-201.1 INADEQUATE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION Jun 29, 2021IN VIOLATION
1535262Apr 9, 2021FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE:ATJun 29, 2021IN VIOLATION
1535252Apr 9, 2021FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN NOTE:AT TIME OF Jun 29, 2021IN VIOLATION
1728928Sep 11, 2020ENTIRE DEVICE INOPERABLE-RETURN TO SERVICE IMMEDIATELYJul 8, 2025IN VIOLATION
486732Jan 12, 202097X10:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AS PER BC3Sep 22, 2020ADMIT/IN-VIO
1236248Jan 17, 2018WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVAug 7, 2018IN VIOLATION
1101557Sep 22, 2017FAILURE TO TO PROVIDE APPROVED/ACCEPTED CONST DOCS @JOBSITE @TIME OF INov 14, 2017IN VIOLATION
815335Apr 12, 2017SEC. 3301.7 FAILURE TO PROVIDE P.E. APPROVED DESIGN DRAWING FOR WORKERMay 30, 2017STIPULATION/IN-VIO
561037Feb 21, 2017PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-2Jul 25, 2017IN VIOLATION
1086141Feb 21, 2017BC3314.1/PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANJul 11, 2017IN VIOLATION
507691Nov 2, 201628-116.2.3 FAILURE TO PROVIDE AN ADEQUATE INSPECTION PROGRAM (TR-1, Feb 21, 2017IN VIOLATION