OpenViolations
/

125 Beach 17 Street

QueensBIN 4436178
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
2
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
33
DOB permit records
Last activity
Apr 14, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

B
Health score · Jul 29, 2026
Scored from the 300 most recent of 540 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 2
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 3
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Records from every agency, interleaved. Showing the 300 most recent of 540 records on file; the CSV below has the full history.

Download this timeline (CSV) →
Apr 14, 2026
Nov 2, 2025
Oct 30, 2025
Oct 24, 2025
Oct 23, 2025
Sep 29, 2025
Sep 12, 2025
May 15, 2025
Dec 9, 2024
Sep 24, 2024
Sep 17, 2024
Aug 6, 2024
Jul 29, 2024
Jul 11, 2024
May 31, 2024
May 24, 2024
May 24, 2024
May 24, 2024
May 24, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024
May 23, 2024

OATH / ECB summonses & fines

No balance is recorded as due across the 27 summonses below, out of $27,375.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 125 Beach 17 Street
1693297Aug 19, 2020NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.Nov 24, 2020IN VIOLATION
1150636Aug 1, 2018FAILURE TO FILE ACCEPTABLE CYCLE 8B REPORT INDICATING CORRECTION OF UNFeb 5, 2019IN VIOLATION
651152Feb 27, 2018FAILURE TO TAKE PROVIDE SAFETY MEASURE SUCH AS SIDEWALK SHEDS FENCE ETApr 17, 2018IN VIOLATION
824391Dec 21, 2016PARTIAL STOP WORK ORDER FOR ALL FACADE JOB AND SUSPENDED SCAFFOLD ISSUFeb 7, 2017IN VIOLATION
1631772Dec 21, 2016PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTE:OBSERVED SFeb 7, 2017IN VIOLATION
1465952Dec 21, 20163310.8.4 PARTIAL STOP WORK ORDER FOR ALL FACADE JOB AND SUSPENDED SCAFFeb 7, 2017IN VIOLATION
1065469Feb 12, 201639I10,39Y02,39O02,59M07,37H08,70O02,16J01. 16J01-ELIMIANTE GAP BETWEENMar 29, 2016STIPULATION/IN-VIO
884461Feb 12, 201644H08,52H11,59M7,56Y02,56Y13,59Y02,02B10,70O02. 59M07-PROVIDE BRAKE MAMar 29, 2016STIPULATION/IN-VIO
1634530Dec 11, 2015FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDIMay 24, 2016IN VIOLATION
1186115Feb 4, 2015FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED AT ENCLOSED Mar 24, 2015STIPULATION/IN-VIO
966358Apr 23, 201250A50B 50A-MUST HAVE FIXED TO BOILER 50B-CANT HAVE ALL PRESSURE CONTROJun 12, 2012STIPULATION/IN-VIO
966359Apr 23, 201250AB 50A-MUST HAVE FIXED LADDER TO BOILER 50B-CANT HAVE ALL PRESSURE CJun 12, 2012STIPULATION/IN-VIO
387311Oct 5, 2010WORK W/O A PERMIT. FOR ALT II JOB #402103889 (3.15.05) - PERMIT EXPIREAug 16, 2011IN VIOLATION
1652466Feb 9, 2010BC1106.1(MISC)PEOPLE WITH PHYSICAL DISABILITIES NOTED:INSUFFICIENT PHYMar 1, 2011DEFAULT
859021Feb 4, 2008FAILURE TO FILE TR1 UPON COMPLETION OF CONTROLLED WORK NOTED PREMISES Sep 1, 2009IN VIOLATION
735498Oct 24, 200511X10/14M07/83E01/17B10/20I10. 11-REPAIR EMERGENCY PHONE, 14-CAB MIRRODec 13, 2005STIPULATION/IN-VIO
735497Oct 24, 200538O02/66Z02/11X10/20I10/83E01/49I10/41A09 66-WATER IN THE PIT, 11-REPADec 13, 2005STIPULATION/IN-VIO
373549Jul 5, 199901B,02B,08V,09I,14M,15I,16I.17I,18L,21L,30B,35O,46H,47H,37G,50Y,73O, 3Apr 12, 2000IN VIOLATION
493190Jun 28, 199973I,74, REPAIR DAMAGE DUE TO FIRE. FAILURE TO REPORT ASSIDENT AS PER Apr 11, 2000IN VIOLATION
493191Jun 28, 199973I,74, REPAIR DAMAGE DUE TO FUIRE, FAILURE TO REPORT ACCIDENT AS PER Apr 11, 2000IN VIOLATION
373493Sep 17, 199840D,37D,74L,16H. SECURE GOVERNOR GUARD, PROPERLY MOUND RELAY TO CONTRONov 12, 1998IN VIOLATION
373495Sep 17, 199835Y,16H,74L. CLEAN OIL FROM ROOM FLOOR, PHASE ONE HAS TO OVER RIDE STONov 12, 1998IN VIOLATION
373323Sep 16, 199840D,22D,74L,16H. FASTEN GOVERNOR GUARD, PHASE ONE HAS TO OVER RIDE STONov 12, 1998IN VIOLATION
1011920Sep 3, 1998FAILURE TO MAINTAIN. DEFECT IS: COLLAPSED SAND/CEMENT PLASTERED CEIL--Jun 9, 1999IN VIOLATION
373020Dec 26, 199758H12,59H12,17D12,74L11,7L11. 58-CAR ROLLERS GUIDE-RAILS REPLACE. Oct 6, 1998IN VIOLATION
372993Dec 26, 199758H12,59H12,40D6,37B6,74L11,15B11. 58-CAR ROLLERS GUIDE-RAILS REPLACEOct 6, 1998IN VIOLATION
372971Dec 26, 199758H12,59H12,74B7,40D6,22D6,50Y11,74O2,15B11,74L11,18B1,17F12,8D6,10B10Oct 6, 1998IN VIOLATION