| 1809714 | Sep 9, 2025 | THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE. | Dec 23, 2025 | DEFAULT | $6,250.00 |
| 1805795 | Jun 30, 2025 | : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVA | Oct 14, 2025 | IN VIOLATION | — |
| 1445651 | Apr 29, 2024 | NO DLM INSTALLED ON THIS CONTROLLER AS MANDATED BY CODE A-17.1 OF THE | Jul 9, 2024 | DEFAULT | $9,345.00 |
| 1166982 | Mar 4, 2024 | DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). NO DLM IN | Jun 18, 2024 | IN VIOLATION | $3,097.00 |
| 1734399 | Jan 24, 2024 | NO DLM INSTALLED ON THIS CONTROLLER . AS MANDATED BY CODE A17.1 SECTIO | Oct 29, 2024 | IN VIOLATION | — |
| 1352613 | Sep 5, 2023 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3. | Dec 12, 2023 | IN VIOLATION | — |
| 85895 | Nov 10, 2014 | 10H11,59O02,16J01,21D10,05I11,39I11,08V01. 39I11-CAR TOP SHACKLE SPRIN | Dec 30, 2014 | ADMIT/IN-VIO | — |
| 911455 | Feb 27, 2014 | 42N11,68B07. 42N11-BYPASSED FUSES ON THE CONTROLLER; 68B07-UPDATE ELEV | Apr 15, 2014 | IN VIOLATION | — |
| 734895 | Nov 1, 2012 | 16J01,21J01,20M07,21M07,20I11,10D06,10I11. 20M- VISION PANEL FOR CAR | Dec 18, 2012 | IN VIOLATION | — |
| 1025679 | Nov 23, 2011 | 10H11, 08V01, 21M07, 42N09, 20M07 42N-FUSES BYPASSED WITH STRANDED WIR | Jan 10, 2012 | DEFAULT | — |
| 887700 | Nov 30, 2009 | 20M07,14M07,42G07,08V01,35Q03. 20-GLASS | Apr 6, 2010 | STIPULATION/IN-VIO | — |
| 432651 | Nov 22, 2000 | FAILURE TO PROVIDE ELEVATOR LANDING SIGN FOR ELEVATOR BANK ON FLOOR 2- | Jul 5, 2005 | IN VIOLATION | — |
| 432653 | Nov 22, 2000 | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYING | Jul 5, 2005 | IN VIOLATION | — |
| 34996 | Apr 4, 2000 | 57O02,05M12,11M07,17M07,75B05,09M07,05L11. 5M- REPLACE CAR DOOR VISION | May 23, 2000 | IN VIOLATION | — |
| 780658 | Apr 30, 1999 | 17L11,8V1,15L11,50Y11,75U5,20L11,10L11. | Jun 22, 1999 | DEFAULT | — |
| 670380 | Sep 15, 1998 | 03H,03I,09O,35P,57O. REPAIR CAR FLOOR, REPAIR CAR BACK PANEL, CLEAN | Nov 10, 1998 | WRITTEN OFF | — |
| 32120 | Nov 21, 1997 | 73O,01I,02I,03I,35P,17I,73X, 03-CAB FLOOR NEEDS TO BE REPLACE 73-RESTO | Mar 10, 1998 | WRITTEN OFF | — |
| 780404 | Oct 21, 1997 | 01X,35P,31Q,03O,13O,57O,63S,08J,74M,05F, 01- DOOR CLOSED & CAR RUN WHE | Dec 9, 1997 | WRITTEN OFF | — |
| 28638 | Jul 7, 1995 | 73X.73-RESTORE ELEVATOR TO SERVICE SO THAT A COMPLETE INSPECTION CAN B | Sep 19, 1995 | WRITTEN OFF | — |
| 26197 | Aug 24, 1993 | 74M,75#,17I,15L,62L. 74 PROVIDE NYC DEVICE #AS REQUIRED. 75 CONDUCT A | Nov 9, 1993 | WRITTEN OFF | — |
| 88650 | Dec 7, 1992 | 11Q,03L,17M,22D,62L,21L,74I, (03) CAR FLOORING (17) BSMT VISION PANEL | Jun 15, 1993 | IN VIOLATION | — |
| 73925 | Apr 20, 1992 | 3O,05M,18L,37G,57O, 3. CLEAN TOP OF CAR. 5 PROVIDE GRILL GUARD. 18. | Jun 23, 1992 | IN VIOLATION | — |
| 780166 | Dec 11, 1990 | 14M,17M,22D,11Q,21L,29L,03L,69M,35P,74#,73O,(17)BSMT DOOR VISION GUARD | Jan 29, 1991 | WRITTEN OFF | — |