| 1273096 | Dec 14, 2020 | PHONE NOT WORKING REPAIR EMERGENCY ESCAPE HATCH UNSECURED PROVIDE | Mar 30, 2021 | IN VIOLATION | — |
| 1273103 | Dec 14, 2020 | PHONE NOT WORKING REPAIR ESCAPE HATCH NOT SECURE PROPERLY SECURE | Mar 30, 2021 | IN VIOLATION | — |
| 659472 | Feb 26, 2016 | REMOVAL OF SIDEWAQLK SHED W/O DEPT'S APPROVAL. NOTE: AT THE TIME OF IN | Jul 26, 2016 | IN VIOLATION | — |
| 1123961 | May 11, 2015 | FAILURE TO MAINTAIN HOUSEKEEPING. AT TIME OF INSPECTION OBSERVED ACTIV | Dec 8, 2015 | IN VIOLATION | — |
| 1123958 | May 11, 2015 | 3307.5.2 FLAG PERSONS:NOT PROVIDED. AT TIME OF INSPECTION OBSERVED ACT | Dec 8, 2015 | IN VIOLATION | — |
| 1051214 | Feb 6, 2015 | 3314.13.2 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISUSED PURSUA | Mar 24, 2015 | IN VIOLATION | — |
| 1051208 | Feb 6, 2015 | PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT TO 28-2 | Mar 24, 2015 | IN VIOLATION | — |
| 1051210 | Feb 6, 2015 | 3314.5 PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD ISSUED PURSUANT | Mar 24, 2015 | IN VIOLATION | — |
| 1013630 | Jan 26, 2015 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE W | Aug 25, 2015 | IN VIOLATION | — |
| 1006124 | Oct 23, 2014 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS;PIPE SCAFFOLD | Mar 17, 2015 | ADMIT/IN-VIO | — |
| 966985 | Oct 23, 2014 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT; GUARDRAILS.AT TIME OF | Dec 9, 2014 | IN VIOLATION | — |
| 1080705 | Oct 23, 2014 | 3308.1.2 HORIZONTAL NETTING REQUIRED DURING ALTERATIONS.AT TIME OF INS | Dec 9, 2014 | IN VIOLATION | — |
| 1123739 | Oct 23, 2014 | FAILURE TO PERFORM SUCCESSFUL HYDROSTATIC PRESSURE TEST OF STANDPIPE | Dec 9, 2014 | IN VIOLATION | — |
| 638740 | Sep 12, 2013 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS MATERIALS | Jan 7, 2014 | IN VIOLATION | — |
| 638659 | Sep 12, 2013 | SEC. EC 250.4. NON-CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROU | Jan 7, 2014 | IN VIOLATION | — |
| 903204 | Apr 1, 2011 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: THE ROOF AND | May 17, 2011 | STIPULATION/IN-VIO | — |
| 567895 | Mar 28, 2008 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPAR | Jan 27, 2009 | IN VIOLATION | — |
| 1029372 | Mar 4, 2008 | SEC. 27-129(D)(I)(A). LOCAL LAW REPORT FILED AS "UNSAFE" UNSAFE CONDIT | Apr 29, 2008 | IN VIOLATION | — |
| 1030618 | Feb 23, 2007 | FAILURE TO MAINTAIN EXTERIOR WALL DEFECTS/NOTED:AT WEST EXPOSURE-PRECA | Apr 24, 2007 | IN VIOLATION | — |
| 44088 | Jan 26, 2007 | 55Y02,55Y13,55A09,60Q03,84D06,66O02,71Q03,71L11,33Q02,33A06,83A01.83A0 | Mar 27, 2007 | STIPULATION/IN-VIO | — |
| 44090 | Jan 26, 2007 | 38O02,84L11,16B01,71Q03.84L11-CAR DOOR CLUTCH,16B01-LOBBY DOOR DOESN'T | Mar 27, 2007 | STIPULATION/IN-VIO | — |
| 285554 | Jan 4, 2003 | ALTERED BUILDING OCCUPIED W/O A VALID C/O ALT TYPE 1 CO # 401452566 EX | Feb 18, 2003 | IN VIOLATION | — |
| 68911 | Feb 24, 1993 | FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUA | Apr 13, 1993 | IN VIOLATION | — |
| 67171 | Oct 20, 1992 | FAILURE TO FILE AN AMENDED REPORT AC CEPTABLE TO THIS DEPARTMENT | Dec 1, 1992 | IN VIOLATION | — |
| 60505 | Aug 5, 1992 | FAILURE TO FILE AN AMENDED REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUA | Oct 20, 1992 | IN VIOLATION | — |
| 325933 | Jan 30, 1991 | 4# PROVIDE KEY | May 28, 1991 | DEFAULT | — |
| 325833 | Sep 28, 1990 | 16L,4H,4)PROVIDE KEY | Nov 13, 1990 | IN VIOLATION | — |
| 325856 | Sep 28, 1990 | 4#,7X,4)PROVIDE KEY | Nov 13, 1990 | IN VIOLATION | — |