OpenViolations
/

47-01 Vernon Boulevard

QueensBIN 4000343
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
3
DOB permit records
Last activity
Jun 30, 2023
Bedbugs record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

A
Health score · Jul 29, 2026
Scored from all 42 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 42 records on file.

Download this timeline (CSV) →
Dec 18, 2023
Jun 30, 2023
Jun 30, 2023
Jun 20, 2023
Jun 20, 2023
Apr 25, 2023
Dec 19, 2022
Sep 17, 2021
Jun 17, 2021
Oct 21, 2020
Sep 16, 2020
Sep 2, 2020
Jun 24, 2020
Jun 23, 2020
Jun 1, 2020
Jun 1, 2020
Jun 1, 2020
May 11, 2020
May 6, 2020
Jan 17, 2020
Jan 17, 2020
Jan 15, 2020
Jan 15, 2020
Jan 15, 2020
Jan 13, 2020
Nov 13, 2019
Oct 9, 2019
Oct 9, 2019
Oct 9, 2019
Aug 15, 2019

OATH / ECB summonses & fines

No balance is recorded as due across the 7 summonses below, out of $10,775.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 47-01 Vernon Boulevard
1527050Jun 24, 2020PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT TIME OF INMar 9, 2021IN VIOLATION
1556965Jun 1, 2020BC 3314.1 FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFOLD.NOTE:AT TIME OF Mar 16, 2021IN VIOLATION
1556111Jan 15, 2020BC 3301.6 DESIGN DRAWINGS-AT TIME OF INSPECTION OF A 4 STORY NB,I OBSESep 8, 2020IN VIOLATION
1556115Jan 15, 2020GUARDRAILS(MISSING)-FAILURE TO INSTITUTE/MAINTAIN SAFETY MEASURES. AT Sep 15, 2020IN VIOLATION
1556114Jan 15, 2020BC 3303.7.2 FIRE EXTINGUISHERS. AT TIME OF INSPECTION OF A 4 STORY NB Dec 15, 2020IN VIOLATION
1251690Oct 9, 2019FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CDec 24, 2019IN VIOLATION
1621020Aug 15, 2019BC 3303.14.2 DRAINAGE OF EXCAVATIONS. NOTE:AT THE TIME OF MY INSPECTIODec 16, 2019IN VIOLATION