OpenViolations
/

8 Nevins Street

BrooklynBIN 3426629
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
14
DOB permit records
Last activity
Jun 9, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

A
Health score · Jul 29, 2026
Scored from all 115 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 115 records on file.

Download this timeline (CSV) →
Jun 9, 2026
Dec 31, 2025
Dec 29, 2024
Jul 25, 2024
Jul 25, 2024
Jul 25, 2024
Jul 25, 2024
Apr 18, 2024
Apr 17, 2024
Dec 30, 2022
Dec 29, 2022
Dec 29, 2022
Dec 27, 2022
Sep 14, 2022
Aug 21, 2022
Jul 14, 2022
Jul 14, 2022
May 4, 2022
Aug 7, 2021
Jun 15, 2021
Jun 15, 2021
Dec 2, 2020
May 8, 2020
Feb 27, 2020
Feb 5, 2020
Aug 21, 2019
Aug 21, 2019
Aug 14, 2019
Aug 14, 2019
Aug 14, 2019

OATH / ECB summonses & fines

No balance is recorded as due across the 29 summonses below, out of $85,455.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 8 Nevins Street
1449805Aug 14, 2019WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVDec 18, 2019IN VIOLATION
1449797Aug 14, 2019BARRIERS.NOTE:AT TIME OF INSPECTION OF ACTIVE JOBSITE,I OBSERVED CONSTDec 18, 2019IN VIOLATION
1449794Aug 14, 2019BC3314.4.3.5/PRE-SHIFT INSPECTION FOR A SUPPORTED SCAFFOLD.NOTE:AT THEDec 16, 2019IN VIOLATION
65369Dec 31, 2018RESPONDENT FAILED TO PROPERLY NOTIFY DEPARTMENT FOR MOBILE CRANE AFT- Apr 29, 2019IN VIOLATION
1289770Dec 7, 2018FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35369919Mar 11, 2019IN VIOLATION
1289781Dec 7, 2018FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35369920Mar 11, 2019IN VIOLATION
1287692Nov 5, 2018HOUSEKEEPING AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. ADEQUATE Feb 4, 2019IN VIOLATION
1366645Nov 5, 2018FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OFeb 4, 2019IN VIOLATION
1447921Oct 30, 2018FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTR.OPERAAug 28, 2019IN VIOLATION
1013642Oct 30, 2018FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTAug 28, 2019IN VIOLATION
1336486May 12, 2018SEC. 3303.8 STANDPIPE SYSTEM DURING CONSTRUCTION. NOTE: AT THE TIME OFAug 22, 2018IN VIOLATION
1336487May 12, 2018WORK AFTER HOURS W/O VARIANCE PERMIT CONTRARY TO 28-105.12.5. NOTE: ATAug 22, 2018IN VIOLATION
1336483May 12, 2018FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. NOAug 22, 2018IN VIOLATION
1336484May 12, 2018SEC. 3308.5 VERTICAL SAFETY NETTING. NOTE: AT THE TIME OF MY INSPECTIOAug 22, 2018IN VIOLATION
1336482May 12, 2018SEC. 1704.24.1 FAIL TO PERFORM HYDROSTATIC TEST-STANDPIPE. NOTE: AT THAug 20, 2018IN VIOLATION
1336485May 12, 2018WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & OR APPROVEDAug 22, 2018IN VIOLATION
1336429May 10, 2018SEC: 3301.2. FAILURE TO MAINTAIN & INSTITUTE SAFETY MEASURES ONSITE: @Jul 9, 2018IN VIOLATION
1277824Mar 12, 2018FAILURE TO COMPLY W/COMM'S ORDER CONTAINED IN SUMMONS/VIO #35255011H IJun 25, 2018IN VIOLATION
1335585Feb 7, 2018WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVMay 1, 2018IN VIOLATION
1267070Feb 7, 2018CONTINUED TO WORK WHILE ON NOTICE OF SWO OBSERVED, CONCRETE OPERATIONSApr 18, 2018IN VIOLATION
236241Feb 5, 2018SEC: BC 3309.1. OVERHEAD PROTECTION. OBSERVED ACTIVE CONSTRUCTION SITEApr 2, 2018IN VIOLATION
1775400Sep 14, 2017WORK DOES NOT CONFORM TO APPROVED/AMENDMEND PLANS. AT TIME OF INSPECTIOct 30, 2017DEFAULT
1264353Jul 5, 2017BC28-105.5 FORMS FILED WITH DEPT.OF BUILDINGS DO NOT HAVE REQUIRED SIGAug 21, 2017STIPULATION/IN-VIO
1220014May 22, 2017FAILURE TO SAFEGUARD.NOTICED AT TIME OF INSPECITON INCIDENT,NOTICED W Dec 7, 2017IN VIOLATION
1293986Feb 11, 2015FAILURE TO CARRY OUT DEMOLITION OPERATIONS AS REQUIRED BY SECTION.OBSEMar 30, 2015DEFAULT
0138048974Nov 24, 2003SIDEWALK OBSTRUCTIONDec 26, 2003WRITTEN OFF
997910Apr 22, 1991WORK WITHOUT A PERMIT WOOD BEAMS INSTALLED AT REAR OF CELLAR WITH WOODJun 10, 1991STIPULATION/IN-VIO
1212090Apr 22, 1991FAILURE TO MAINTAIN REQUIRED REAR EXIT AT THE 1 TOTALY OBSTRUCTED WITHJun 10, 1991IN VIOLATION
1359003Apr 22, 1991FAILURE TO MAINTAIN FIRE ESCAPE STAIR AT ROOF LEVEL & FIRE ESCAPE BALCJun 10, 1991IN VIOLATION