OpenViolations
/

461 Dean Street

BrooklynBIN 3398591
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
5
DOB permit records
Last activity
May 19, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

A
Health score · Jul 29, 2026
Scored from all 114 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 3
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 114 records on file.

Download this timeline (CSV) →
May 19, 2026
Apr 2, 2026
Mar 9, 2026
Dec 2, 2025
Nov 20, 2025
Sep 8, 2025
Sep 8, 2025
Dec 2, 2024
Nov 21, 2024
Oct 10, 2024
Jul 26, 2024
Dec 5, 2023
Nov 16, 2023
Nov 2, 2023
Oct 5, 2023
Jun 20, 2023
Jun 20, 2023
Jun 20, 2023
May 8, 2023
Mar 7, 2023
Dec 12, 2022
Mar 31, 2022
Feb 25, 2022
Dec 6, 2021
Dec 23, 2020
Nov 17, 2020
Sep 30, 2020
Jul 2, 2020
Jul 2, 2020
Jul 2, 2020

OATH / ECB summonses & fines

No balance is recorded as due across the 16 summonses below, out of $60,080.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 461 Dean Street
1501985Jul 2, 2020CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR CLASS 2 ITEMS: ROUGE Nov 4, 2020IN VIOLATION
1491409Feb 18, 2020DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLE C/U. DLM TAG MIJun 24, 2020IN VIOLATION
1491410Feb 18, 2020DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLE C/U. CLOSE GAP Jun 24, 2020IN VIOLATION
1241295Feb 15, 2017SIDEWALK SHED DOES NOT MEET COLOR SPECIFICATIONS.NOTE:AT TIME OF INSPEOct 4, 2017IN VIOLATION
911736Aug 27, 2016SUPERVISION OR USE OF POWER-OPERATED HOISTING MACHINE WITHOUT A HOISTIDec 28, 2016IN VIOLATION
1252366Aug 15, 2016CN 746/13;CD4499.INADEQUATE SAFETY MEASURES;OPERATION OF CRANE IN UNSAAug 30, 2017IN VIOLATION
1184461Jul 21, 2016FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONSep 12, 2016IN VIOLATION
422946Mar 29, 2016FAILURE TO PROVIDE INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMJul 25, 2016ADMIT/IN-VIO
422830Mar 29, 2016BC3301.2 ADEQUATE MEANS OF EGRESS.NOTE @ THE TIME OF INSPECTION OF A 2Jul 25, 2016ADMIT/IN-VIO
423145Mar 29, 2016BC3301.6.1 CONCRETE EMBEDDED STRAPS-DESIGN.NOTE @ THE TIME OF INSPECTIJul 29, 2016ADMIT/IN-VIO
1126519Aug 17, 20153320.2 OPERATION OF(DEFECTIVE)HOISTING EQUIPMENT.TOWER CRANE CD 4494,COct 5, 2015ADMIT/IN-VIO
400262Jul 22, 20153303.8 STANDPIPE NOT IN A STATE OF READINESS.AT TIME OF INSPECTION OBSSep 21, 2015DEFAULT
750170Dec 11, 2014FAILURE TO PROVIDE APPROVED ACCEPTED PLANS @ JOBSITE @ TIME OF INSP.@ Jan 26, 2015DEFAULT
580845Sep 16, 2014OPERATION OF CRANE WITH EXPIRED CD. AT TIME OF INSPECTION CD#4499 CN#7Jan 28, 2015IN VIOLATION
956046Apr 2, 2014FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONMay 19, 2014IN VIOLATION
645794Sep 23, 20133320.3.1,RS19-2.18 PARTIAL *SWO*.IMPROPERLY MARKED,UNIDENTIFIED RIGGINDec 2, 2013ADMIT/IN-VIO