OpenViolations
/

20 Bayard Street

BrooklynBIN 3391875
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
14
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
68
DOB permit records
Last activity
Aug 4, 2025
ECB/OATH record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

B
Health score · Jul 29, 2026
Scored from all 225 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 14
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 225 records on file.

Download this timeline (CSV) →
Aug 4, 2025
Jun 3, 2025
Feb 3, 2025
Jan 2, 2025
Jan 12, 2024
Dec 31, 2023
Dec 30, 2022
Dec 13, 2022
Feb 15, 2022
Dec 29, 2021
Aug 6, 2021
Aug 5, 2021
Aug 5, 2021
Aug 5, 2021
Aug 5, 2021
Jul 2, 2021
Jul 2, 2021
Jul 2, 2021
Jul 2, 2021
Jul 2, 2021
Jul 2, 2021
Jul 2, 2021
Jul 1, 2021
Jul 1, 2021
Jul 1, 2021
Apr 13, 2021
Apr 13, 2021
Jan 28, 2021
Oct 26, 2020
Mar 7, 2020

OATH / ECB summonses & fines

No balance is recorded as due across the 29 summonses below, out of $159,010.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 20 Bayard Street
1594185Jul 1, 2021COMPONENT BOILERS OF SLANT FIN CARAVAN BOILER MODULE HAVE ISOLATION VADec 1, 2021IN VIOLATION
1594188Jul 1, 2021COMPONENT BOILERS OF SLANT FIN CARAVAN BOILER MODULE HAVE ISOLATION VADec 1, 2021IN VIOLATION
1538174Dec 5, 2018FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE Mar 11, 2019Resolved
839698Dec 5, 2018PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIALMar 11, 2019DEFAULT
711148Dec 5, 2018FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE Mar 11, 2019ADMIT/IN-VIO
1538188Dec 5, 2018FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF Mar 11, 2019Resolved
839715Aug 14, 2018PERMANENT DWELLING OFFERED FOR OTHER THANN PERMANENT-RESIDENTIAL PURPOOct 29, 2018IN VIOLATION
1538258Aug 14, 2018FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE A CERT OF CORRECTION W/THNov 7, 2018IN VIOLATION
1536106May 16, 2017PERMANENT DWELING OCCUPIED/CONVERTED FOR OTHER THAN PERMANANT RESIDENTNov 6, 2017IN VIOLATION
31781Oct 24, 2007EXPIRED PERMIT. NOTED: EXTERIOR HOIST PERMIT #3V21630 EXPIRED 8/30/07.Dec 17, 2007DEFAULT
21314Jul 17, 2007NO GUARDRAILS.AT TIME OF INSPECTION NO GUARDRAILS AT FRONT OF BLDG PROSep 18, 2007IN VIOLATION
256048Dec 12, 2006UNSAFE STORAGE OF MATERIALS AT EDGE OF BLDG. ON INSP PIPE SCAFFOLD, BRApr 16, 2007IN VIOLATION
1085544Apr 28, 2006FAILURE TO CARRY OUT DEMO OPERATIONS IN A SAFE & PROPER MANNER UPON INMay 7, 2007WRITTEN OFF
6551Feb 25, 2006FAILURE TO HAVE SITE SAFETY MGR. PRESENT AS REQUIRED. AS NOTED PLUMBINJan 24, 2007IN VIOLATION
592357Feb 18, 2006WEDGES IN RESHORES W/IN TEN FT OF FACADE. NOTED. AT TIME OF INSP. AN AApr 3, 2006IN VIOLATION
591505Feb 16, 2006NO SITE SAFETY LOG PER REGULATIONS. NOTE NEW SEVENTEEN STORY BLDG BEINApr 3, 2006IN VIOLATION
591496Feb 16, 2006FAILURE TO PROTECT ROOFS,ROOF OUTLETS OR SKYLIGHTS OF ADJOINING PROPERApr 3, 2006IN VIOLATION
591497Feb 16, 2006FAILURE TO POST PERMIT. NOTE NEW SEVENTEEN STORY BLDG BEING ERECTED WIApr 3, 2006IN VIOLATION
591503Feb 16, 2006NO GUARD RAILS. NEW SEVENTEEN STORY BLDG BEING ERECTED AND NO PROTECTIApr 3, 2006IN VIOLATION
189313Feb 9, 2006WORK W/O A PERMIT. AS NOTED: AS PER DOB RECORDS, NO PERMIT IS ON FILE Apr 2, 2007IN VIOLATION
603295Jan 20, 2006WORK W/O A PERMIT. AS NOTED: AS PER DOB RECORDS, THERE IS NO PERMIT FOApr 3, 2006IN VIOLATION
590171Jan 20, 2006WEDGES USED IN RESHORES W/IN TEN FT OF FACADE. AS NOTED: WEDGES USED IApr 3, 2006IN VIOLATION
187055Jun 29, 2005FAILURE TO PROVIDE ADEQUATE PROTECTION FOR SIDEWALK AND WALKWAYS DURINApr 30, 2007IN VIOLATION
614991Feb 2, 2005FAILURE TO PROVIDE A DESIGNATED SITE SAFETY MANAGER PRESENT WILL ON GOMar 21, 2005DEFAULT
509101Jan 27, 2005FAILURE TO PROVIDE APPROVED PLANS AT PREMISES AT TIME OF INSPECTION. NMar 14, 2005WRITTEN OFF
1016513Dec 1, 2004FAILURE TO MAINTAIN. NOTE. GALVANIZE FENCE ERECTED UNDER PERMIT #30149Oct 31, 2005WRITTEN OFF
506968Oct 20, 2004FAILURE TO PROVIDE DRAINAGE. UPON INSPECTION AT ABOVE PROPERTY NOTED: Dec 6, 2004IN VIOLATION
563976Jun 28, 2004FAILURE TO PROVIDE A DESIGNATED SITE SAFETY MANAGER PRESENT WILL OR GOSep 13, 2004IN VIOLATION
586891Mar 9, 2004FAILURE TO PROVIDE 24 HR NOTICE PRIOR TO STARTING CONSTRUCITON UPON INMay 24, 2004IN VIOLATION