OpenViolations
/

243 Kingston Avenue

BrooklynBIN 3324522
5 open Class C$13,438.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
5
Immediately hazardous
Open Class B
12
Hazardous
Open Class A
0
Non-hazardous
Fines due
$13,438.00
Balance on OATH/ECB summonses
Permits on file
5
DOB permit records
Last activity
Jul 22, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

D
Health score · Jul 29, 2026
Scored from all 122 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 5
Open Class B violations
Hazardous
This building 12
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $13,438
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 1
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 122 records on file.

Download this timeline (CSV) →
Jul 22, 2026
May 26, 2026
Jun 16, 2025
Mar 25, 2025
Jan 24, 2025
Apr 16, 2024
Apr 15, 2024
Feb 12, 2024
Feb 12, 2024
Feb 12, 2024
Feb 12, 2024
Feb 12, 2024
Jan 29, 2024
Jan 29, 2024
Jan 29, 2024
Jan 18, 2024
Mar 30, 2023
Aug 24, 2022
Jul 13, 2022
Jan 10, 2022
Mar 17, 2021
Mar 3, 2021
Mar 3, 2021
Mar 3, 2021
Mar 3, 2021
Mar 3, 2021
Sep 2, 2020
Mar 24, 2020
Mar 24, 2020
Mar 23, 2020

OATH / ECB summonses & fines

$13,438.00 is recorded as due across the 10 summonses below, out of $20,548.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 243 Kingston Avenue
1719388Aug 24, 20221,I,10 IN CAR STOP SWITCH GLUED INTO CAR BUTTON STATION IN BOTH CARS. May 1, 2023DEFAULT$1,562.00
1537925Mar 3, 2021ROOF BOILER ROOM THE BOILER FLUE HAS DEFECTIVE GASKETS ÝLEAKING¨/ BOILAug 4, 2021IN VIOLATION$625.00
1633171Mar 3, 2021CELLAR BOILER ROOM THE TRI GAUGE ON THE BOILER IS DEFECTIVE; CORRECT VJul 7, 2021DEFAULT$1,562.00
1008420Mar 3, 2021ROOF BOILER ROOM THE OUTSIDE FLUE TERMINATION KIT IS DEFECTIVE/ BOILERJul 7, 2021DEFAULT$1,562.00
1633174Mar 3, 2021CELLAR BOILER ROOM THE TRI GAUGE AT THE SYSTEM AIR SEPARATOR IS DEFECTJul 7, 2021DEFAULT$1,562.00
1346725Mar 24, 2020CLASS ONE ITEM: DLM INACTIVE AS PER CODE REQUIREMENTS CLASS 2 ITEMS: PJul 29, 2020DEFAULT$6,250.00
1535263Mar 24, 2020INOPERATIVE PHONE. OIL IN PIT. REMOVE WIRE TIES FROM MAIN LINE AND AC Jul 29, 2020STIPULATION/IN-VIO$315.00
830104Oct 30, 2013TIE BACKS & LIFE LINES ARE NOT PROPERLY ANCHORED. NOTED: AT TIME OF INDec 16, 2013IN VIOLATION
988390Jul 17, 2013*21N10- REPAIR JUMPED DOOR LOCK IN THE BASEMENT. SO LIFE C-USE CALL 21Dec 30, 2013IN VIOLATION
63339May 2, 199173M OPERATION OF ELEVATOR DEVICE WITH EXPIRED USE PERMIT FAILURE TO COJun 17, 1991DEFAULT