| 1333586 | Nov 5, 2020 | (05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH | Mar 10, 2021 | ADMIT/IN-VIO | — |
| 1760608 | Nov 5, 2020 | (05-A-10) CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH | Mar 10, 2021 | ADMIT/IN-VIO | — |
| 1706795 | Feb 6, 2020 | (C/U 56Y13);(C/U 56Y2);(C/U 29J01),16L11,67X10:CEASE USE/56Y-SEAL OIL | Jul 27, 2020 | DEFAULT | — |
| 1706796 | Feb 6, 2020 | 44H10,52H11,44-05,52-17,16L11,67X10:44/52H-REPLACE SHEAVE&CABLES. FILE | Jul 27, 2020 | DEFAULT | — |
| 1694430 | Mar 28, 2015 | B254,15,50A,50B,50C,50D,50E,50F. 50A-SAIL SWITCH FOR FRESH AIR FAN NOT | May 18, 2015 | IN VIOLATION | — |
| 1349172 | Aug 9, 2013 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE IN APT 9H,BALC | Sep 23, 2013 | STIPULATION/IN-VIO | — |
| 1234089 | Apr 2, 2008 | SEC.27.129(D)(1)(A).CYCLE 6 LOCAL LAW REPORT FILED AS"UNSAFE".UNSAFE C | Jun 2, 2008 | WRITTEN OFF | — |
| 621829 | Sep 5, 2007 | 83X10/.83-REPAIR & RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE | Oct 29, 2007 | IN VIOLATION | — |
| 706055 | Mar 30, 2007 | 14M7/16H11/17H11/.14-M-7-PROVIDE MISSING CORNER MIRROR.16-H-11-REPLACE | May 21, 2007 | IN VIOLATION | — |
| 657362 | Mar 30, 2007 | 16H11/17H11/40D6/38O2/55Y10/.16-H-11-REPLACE WORN HOISTWAY DOOR SADDLE | May 21, 2007 | IN VIOLATION | — |
| 847174 | Dec 6, 2006 | FAILURE TO MAINTAIN BLDG-HAZ.NOTED:10 STORY HIGH STEEL BOILER EXHAUST | Dec 26, 2007 | IN VIOLATION | — |
| 940518 | Oct 30, 2006 | 43H11/39B07.39B07-MACHINE ROOM 6FC1 | Dec 18, 2006 | STIPULATION/IN-VIO | — |
| 583623 | Oct 26, 2005 | 56M06/29M07/30M07/41H11/12Q03/05H11/84M07 56-M- MOTOR GEN SPLICE BOX C | Dec 12, 2005 | IN VIOLATION | — |
| 402084 | Oct 26, 2005 | 83X10/41G11/12Q03 83-X, MAKE REPAIRS, RESTORE TO SERVICE. 41-G JUMPED | Dec 12, 2005 | IN VIOLATION | — |
| 628618 | Oct 6, 2005 | FALSE CERTIFICATION FILED WITH NYC DEPT OF BUILDING, PURSUIANT TO SECT | Jan 19, 2006 | IN VIOLATION | — |
| 628592 | Sep 30, 2005 | 16J10/41L10. | Jan 9, 2006 | IN VIOLATION | — |
| 401858 | Sep 30, 2005 | 05J01/08V01/05F10/05B01/64M07. 05-FINGER TRAP CAR GATE. 08-ADJUST LEVE | Nov 14, 2005 | IN VIOLATION | — |
| 181285 | Apr 18, 2005 | FAILURE TO MAINTAIN NOTED DEFECTS:INTERIOR ACOUSTICAL CEILING(SUSPENDE | Mar 28, 2007 | IN VIOLATION | — |
| 262028 | Apr 25, 2003 | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION | Aug 11, 2003 | IN VIOLATION | — |
| 644963 | Jan 31, 2003 | FAILURE TO MAINTAIN BUILDING DEFECT IS: HEATING VENT PIPE AT REAR ROTT | Mar 17, 2003 | DEFAULT | — |
| 607610 | Dec 2, 2002 | 34A/50. ILLEGAL WIRING ON LOW WATER CUT OFF (MUST BE BX CABLE AND/OR T | Jan 27, 2003 | DEFAULT | — |
| 581394 | Nov 18, 2002 | 62O02-67M02-39G12-39G12-56U16. 67M TOE GUARD MISSING. 39G REMOVE WIRE | Jan 6, 2003 | IN VIOLATION | — |
| 581397 | Nov 18, 2002 | 17M07-11B11-80O02-67M07-05J01-62O02-39G12-41H08. 17M 8TH FLOOR. 11B CA | Jan 6, 2003 | IN VIOLATION | — |
| 374622 | Nov 16, 2002 | 03H11/50O02/74X07/54M07/74M07/74O02/57O02. 03H WORM CAR FLOOR. 50O BRU | Dec 30, 2002 | STIPULATION/IN-VIO | — |
| 374617 | Nov 16, 2002 | 03H11/37N09/74X07/54M07/74O02/58O02/57O02/74M07. 03H WORN CAR FLOOR. 3 | Dec 30, 2002 | STIPULATION/IN-VIO | — |
| 704047 | May 8, 2002 | 37G12/9H12/57O2/(37)REMOVE WIRE FROM FUSE IN CONTROLLER(9)REPLACEMENT | Jun 24, 2002 | DEFAULT | — |
| 704046 | May 8, 2002 | 73X11/37912-(73)REPAIR & RESTORE ELEVATOR TO SERVICE (37)REMOVE WIRE F | Jun 24, 2002 | DEFAULT | — |
| 610240 | Aug 27, 1996 | FAILURE TO MAINTAIN EXTERIOR BLDG WALL DEFECT IS:VERTICAL CRACK AT FIR | Oct 7, 1996 | WRITTEN OFF | — |
| 226315 | Jun 27, 1991 | 09H,16H,57O | Apr 20, 1992 | IN VIOLATION | — |