| 1410988 | Aug 19, 2019 | PERMIT HOLDER FAILED TO PRODUCE FOR INSPECTION THE DAILY LOG THAT IS R | Oct 11, 2019 | IN VIOLATION | — |
| 1482677 | Jun 25, 2019 | 3314.4.8 FAILURE TO MAINTAIN SUPP SCAFFOLD AS PER CODE.AT THE TIME OF | Feb 24, 2020 | IN VIOLATION | — |
| 1405429 | May 22, 2019 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AS PER SECTION REQUIREMENT. | Sep 9, 2019 | IN VIOLATION | — |
| 1268876 | Dec 11, 2018 | UNLAWFUL ACT, FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. REC | Jul 1, 2019 | IN VIOLATION | — |
| 1267707 | Aug 29, 2018 | FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED AT GENERATOR INSUFFICIE | Apr 1, 2019 | IN VIOLATION | — |
| 1267699 | Aug 29, 2018 | FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS. OBSERVED AT GENERATOR, NE | Apr 1, 2019 | IN VIOLATION | — |
| 1267706 | Aug 29, 2018 | UNAPPROVED, UNSAFE, UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS, MATERIA | Apr 1, 2019 | IN VIOLATION | — |
| 673627 | Aug 6, 2018 | INADEQUATE LOGS PREVIOUSLY NOTED ON VIOLATION 35319313N ISSUED 7/31/18 | Oct 29, 2018 | STIPULATION/IN-VIO | — |
| 1179043 | Jul 31, 2018 | SEC. 3301-02(D) LOGS-INADEQUATE: AS NOTED: AT TIME OF INSPECTION ON AN | Dec 17, 2018 | IN VIOLATION | — |
| 1181723 | Jul 28, 2018 | SEC. 3307.2.3 NO OVERHEAD PROTECTION AT EXP#4 FRONT. AT TIME OF INSPEC | Dec 24, 2018 | IN VIOLATION | — |
| 1346117 | Jul 28, 2018 | SEC. 3307.7 NO NETTING BETWEEN FENCE & SIDEWALK SHED. AT TIME OF INSPE | Dec 24, 2018 | IN VIOLATION | — |
| 1236027 | Jul 24, 2018 | FAILURE TO PROVIDE P.E. APPROVED DESIGN DRAWING FOR D RINGS STRAPS THA | Oct 22, 2018 | IN VIOLATION | — |
| 926025 | Jul 24, 2018 | FAILURE TO PERFORM PROPER CONCRETE WASHOUT PROCEDURES AT SITE COLLEC | Nov 19, 2018 | IN VIOLATION | — |
| 1322325 | Jul 24, 2018 | FAILURE TO SECURE RESHORES IN PROXIMITY TO THE FACADE. AS NOTED: AT | Oct 22, 2018 | IN VIOLATION | — |
| 1299911 | Apr 6, 2018 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENT AT JOBSITE | Jul 30, 2018 | IN VIOLATION | — |
| 1235174 | Apr 6, 2018 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION | Jul 31, 2018 | IN VIOLATION | — |
| 1235177 | Apr 6, 2018 | FAILURE TO PROTECT ADJOINING PROPERTY DURING EXCAVTION OPERTIONS AT | Jul 31, 2018 | IN VIOLATION | — |
| 1229550 | Apr 6, 2018 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE. AT | Nov 7, 2018 | IN VIOLATION | — |
| 1235180 | Apr 6, 2018 | FAILURE TO PROVIDE PROTECTION AT SIDE OF EXCAVATION. AT TIME OF INSPEC | Jul 31, 2018 | IN VIOLATION | — |
| 340906 | Mar 17, 2018 | SEC. 3303.4.1.1 TRIPPING HAZARD(BROKEN PEDESTRIAN WALKWAY)AT TIME OF I | May 14, 2018 | IN VIOLATION | — |
| 1248583 | Aug 30, 2017 | FAILURE TO SAFEGUARD ALL PERSONS,PUBLIC AND PROPERTY.AT TIME OF INSPEC | Nov 3, 2017 | IN VIOLATION | — |
| 1259072 | Aug 30, 2017 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AT TIME OF INSPECTION OBSERV | Nov 3, 2017 | IN VIOLATION | — |