| 922333 | Nov 10, 2022 | INSP.DATE10/18/22BADGE#3181 ISSUED 5 ECBS W/SWO NO WORK EXP2,3 (..09K, | Apr 24, 2023 | ADMIT/IN-VIO | — |
| 1644904 | Oct 18, 2022 | A 7 STORY NB ACTIVE SITE. OBSERVED COMBUSTIBLE CONSTRUCTION MATERIALS | Dec 2, 2022 | IN VIOLATION | — |
| 307328 | Jan 6, 2022 | FAIL TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCS.AT JOBSITE AT TIME | Oct 17, 2022 | IN VIOLATION | — |
| 550939 | Jan 6, 2022 | COMPETENT PERSON.AT TIME OF INSPECTION AT A NEW 7 STORY BUILDING ACTIV | Sep 23, 2022 | IN VIOLATION | — |
| 1663942 | Jan 6, 2022 | FAILURE TO PROVIDE APPROVED CONCRETE WASH OUT BOX/CONTAINER.NOTE:AT TI | Feb 24, 2023 | ADMIT/IN-VIO | — |
| 792655 | Jan 6, 2022 | SITE SAFETY ORIENTATION.AT TIME OF INSPECTION AT NEW 7 STORY BLDG ACTI | Feb 24, 2023 | ADMIT/IN-VIO | — |
| 1638425 | Dec 28, 2021 | WORK CONTRARY TO APPROVED DESIGN DRAWING.NOTE:AT THE TIME OF INSPECTIO | Feb 10, 2023 | IN VIOLATION | — |
| 307322 | Dec 28, 2021 | MISSING FENCE. NOTE:AT THE TIME OF INSPECTION OBSERVED A 7 STY BUILDIN | Oct 17, 2022 | IN VIOLATION | — |
| 1638427 | Dec 28, 2021 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER.NOTE:AT T | Feb 10, 2023 | IN VIOLATION | — |
| 1638423 | Dec 28, 2021 | BC33098-PROTECT ADJOINING WALLS DURING EXCAVATION.NOTE:AT THE TIME OF | Feb 10, 2023 | IN VIOLATION | — |
| 1638422 | Dec 28, 2021 | NO SUPPORT OF EXCAVATION.NOTE:AT THE TIME OF COMPLAINT INSPECTION OBSE | Feb 10, 2023 | IN VIOLATION | — |
| 1570868 | Oct 13, 2021 | JOB SITE FENCE NOT IN PLACE,MAINTAINED OR INADEQUATE.AT TIME OF INSPEC | Jan 7, 2022 | IN VIOLATION | — |
| 1479237 | Oct 13, 2021 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS.AT TIME OF INSPECTION ON | Jan 7, 2022 | IN VIOLATION | — |
| 1565828 | Oct 13, 2021 | FAILURE TO MAINTAIN/RPOVIDE PROTECTION FOR SIDES AT EXCAVATION(MORE TH | Jan 7, 2022 | IN VIOLATION | — |
| 1497037 | Oct 13, 2021 | WORK CONTRARY TO CONSTRUCTION DOCUMENTS AT TIME OF INSPECTION ON AN AC | Jan 7, 2022 | IN VIOLATION | — |
| 1565822 | Oct 13, 2021 | SUPERINTENDENT FAILED TO DESIGNATE & HAVE COMPETENT PERSON ON SITE.AT | Jan 7, 2022 | IN VIOLATION | — |
| 1565819 | Oct 13, 2021 | SUPERINTENDENT FAILED TO CORRECT OR NOTIFY OF UNSAFE CONDITIONS ON SIT | Jan 7, 2022 | IN VIOLATION | — |
| 1356023 | Oct 13, 2021 | BC3307.7.2 FAILURE TO MAINTAIN CONSTRUCTION GATE AS PER CODE.AT TIME | Jan 7, 2022 | IN VIOLATION | — |
| 1565833 | Oct 13, 2021 | BC3304.7 FAILURE TO PROVIDE & MAINTAIN ADEQUATE ACCESS,INGRESS,EGRESS | Jan 7, 2022 | IN VIOLATION | — |
| 1309396 | Sep 17, 2021 | SAFETY MEASURES.AT TIME OF INSPECTION OF 7 STORY NEW BUILDING JOB SITE | Dec 3, 2021 | IN VIOLATION | — |
| 1309186 | Sep 17, 2021 | JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.AT | Dec 3, 2021 | IN VIOLATION | — |