OpenViolations
/

1070 Washington Avenue

BronxBIN 2129067
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
25
DOB permit records
Last activity
Dec 17, 2025
Bedbugs record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

A
Health score · Jul 29, 2026
Scored from all 121 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 121 records on file.

Download this timeline (CSV) →
Dec 17, 2025
Dec 23, 2024
Dec 6, 2023
Oct 25, 2023
Jun 30, 2023
Jun 30, 2023
Jan 18, 2023
Jan 12, 2023
Jan 11, 2023
Jan 11, 2023
Jan 10, 2023
Jan 9, 2023
Jan 8, 2023
Jan 8, 2023
Jan 8, 2023
Jan 8, 2023
Jan 8, 2023
Jan 3, 2023
Dec 30, 2022
Dec 13, 2022
Jun 1, 2022
Mar 14, 2022
Jan 20, 2021
Jan 7, 2020
May 2, 2019
May 1, 2019
Feb 24, 2017
Feb 24, 2017
Jan 3, 2017
Jul 19, 2016

OATH / ECB summonses & fines

No balance is recorded as due across the 14 summonses below, out of $14,500.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 1070 Washington Avenue
1041545Nov 2, 2013SEC. 3303.8 SIAMESE LOSE CONNECTION NOT RED LIGHT NOT WORKING. NO BULBFeb 14, 2014IN VIOLATION
1016533Oct 2, 2013FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONNov 29, 2013IN VIOLATION
1016540Oct 2, 2013FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMP CONSTRNov 29, 2013IN VIOLATION
1037778Oct 2, 2013SEC. 3314.5.5. NUMEROUS PLANKS ON SCAFFOLDING AT EXPS 1 AND 2 WERE OBSNov 29, 2013IN VIOLATION
1037779Oct 2, 2013SEC. 28-105.12.2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENov 29, 2013IN VIOLATION
852280Oct 2, 2013SEC. 3314.8. NO GUARDRAIL SYSTEM HAS BEEN PROVIDED AND/OR ERECTED ON Nov 29, 2013IN VIOLATION
1005935Oct 2, 2013SEC. 3307.3.2. SITE HAS NOT BEEN ENCLOSED W/AN 8'HIGH SOLID FENCE. FENNov 29, 2013STIPULATION/IN-VIO
1016535Oct 2, 2013FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY Nov 29, 2013IN VIOLATION
1037777Oct 2, 2013SEC. 3314.4.4. MATERIAL, DEBRIS AND TOOLS (EQUIPMENT) SUCH AS BRICKS, Nov 29, 2013IN VIOLATION
1016534Oct 2, 2013FAILURE TO (PROTECT) SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONov 29, 2013IN VIOLATION
1035419Oct 2, 2013SEC. 3314.8.10. TOE BOARDS HAVE NOT BEEN ERECTED ALONG THE EDGE OF THEFeb 21, 2014IN VIOLATION
793903Dec 5, 2012WORK W/O PERMIT NOTED AT 2-STORY NEW BLDG UNDER CONSTRUCTION TEMPORARYFeb 22, 2013IN VIOLATION
139074Jul 1, 1991FAILURE TO MAINTAIN. DEFECT IS BROKEN & DEFECTIVE FLOOR & CEILING GEANSep 13, 1991WRITTEN OFF
138986Mar 15, 1991FAILURE TO MAINTAIN DEFECTIVE IS: WOODS FLOOR JOINTS RATLED AND DEFECTAug 23, 1991WRITTEN OFF