OpenViolations
/

3220 Arlington Avenue

BronxBIN 2109355
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
83
DOB permit records
Last activity
Dec 2, 2025
Bedbugs record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

A
Health score · Jul 30, 2026
Scored from all 249 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 249 records on file.

Download this timeline (CSV) →
Dec 2, 2025
Dec 27, 2024
Feb 28, 2024
Dec 5, 2023
Oct 17, 2023
Apr 6, 2023
Mar 30, 2023
Dec 16, 2022
Sep 7, 2022
Aug 17, 2022
Aug 11, 2022
Aug 5, 2022
May 24, 2022
May 20, 2022
Dec 20, 2021
Dec 20, 2021
Dec 20, 2021
Dec 16, 2021
Sep 10, 2021
Sep 9, 2021
May 5, 2021
Apr 22, 2021
Feb 10, 2021
Dec 21, 2020
Nov 5, 2020
Jul 15, 2020
May 15, 2020
May 15, 2020
May 15, 2020
May 23, 2019

OATH / ECB summonses & fines

No balance is recorded as due across the 16 summonses below, out of $18,050.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 3220 Arlington Avenue
910719Dec 20, 2021FAILURE TO PROVIDE PEDESTRIAL PROTECTION.AT TIME OF INSPECTION OF 15 SMar 18, 2022IN VIOLATION
1499802Sep 10, 2021UNAPPROVED UNSAFE WIRING. THERE ARE 2 SETS OF WIRES COMING FROM A.C. CDec 3, 2021STIPULATION/IN-VIO
1051011Oct 15, 2018FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION Mar 7, 2019IN VIOLATION
1767771Jul 24, 2017FAILURE TO MAINTAIN EXTERIOR BUILDING WALL.NOTED:DEFECTIVE,CRACKED,SPASep 15, 2017IN VIOLATION
1483242Oct 20, 2015FAILURE TO MAINTAIN EXTERIOR BLDG WALL.DEFECT IS:DEFECTIVE CRACKED SPADec 18, 2015IN VIOLATION
1268260Mar 11, 2015NEW BLDG 200859053 IS OCCUPIED W/OUT A VALID C OF O WHICH EXPIRED 2/10May 1, 2015WRITTEN OFF
896328Mar 24, 2010UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.STOP WOOct 22, 2010IN VIOLATION
791032Feb 9, 2010BC3314.9 SUPPORTED SCAFFOLD DOES NOT MEET DOB SPECIFICATIONS MISSING GJun 11, 2010IN VIOLATION
791039Feb 9, 2010ERECTED OR INSTALLED SUPPORTED SCAFFOLD 40FT OR HIGHER W/O A PERMIT SUJun 11, 2010IN VIOLATION
549579Jul 26, 2005NO PERMIT FOR PERSONAL HOIST. UPON INSP A HOIST HAS BEEN ERECTED WITHONov 25, 2005IN VIOLATION
549576Jul 26, 2005HORIZONTAL SAFETY NETTING NOT PROVIDED. UPON INSPECTION NO HORIZONTAL Nov 25, 2005IN VIOLATION
549574Jul 26, 2005NO ELEVATOR IN READINESS. UPON INSPECTION HOIST ERECTED NO DROP TEST PNov 25, 2005IN VIOLATION
549582Jul 26, 2005FAILURE TO PROVIDE ROOF PROTECTION OF ADJOINING PROPERTIES. UPON INSP Nov 25, 2005IN VIOLATION
549578Jul 26, 2005NO STAND PIPE SYSTEM. UPON INSPECTION BLD AT 11TH FL APROX HIGHT APROXNov 25, 2005IN VIOLATION
700264Apr 6, 2005FAILURE TO PROVIDE 24 HR. NOTICE. UPON INSPECTION NO 24 HR. NOTICE GIVMay 20, 2005IN VIOLATION
700278Apr 6, 2005FAILURE TO PROVIDE 24 HR. NOTICE PRIOR TO START OF DEMOLITION.UPON INSMay 20, 2005IN VIOLATION