OpenViolations
/

500 West 235 Street

BronxBIN 2084059
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
21
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
8
DOB permit records
Last activity
Jul 2, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

C
Health score · Jul 29, 2026
Scored from all 277 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 21
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 1
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 277 records on file.

Download this timeline (CSV) →
Jul 2, 2026
Dec 4, 2025
Jun 15, 2025
Dec 2, 2024
Sep 13, 2024
Jun 23, 2024
Apr 22, 2024
Apr 4, 2024
Apr 3, 2024
Apr 2, 2024
Apr 2, 2024
Apr 2, 2024
Apr 2, 2024
Apr 2, 2024
Apr 2, 2024
Apr 1, 2024
Feb 22, 2024
Feb 21, 2024
Feb 21, 2024
Feb 21, 2024
Feb 6, 2024
Feb 6, 2024
Feb 6, 2024
Feb 6, 2024
Feb 6, 2024
Jan 5, 2024
Jan 5, 2024
Oct 2, 2023
Oct 2, 2023
Oct 2, 2023

OATH / ECB summonses & fines

No balance is recorded as due across the 31 summonses below, out of $30,465.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 500 West 235 Street
1737069Sep 13, 2024FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES.NOTE:AT TIMNov 29, 2024STIPULATION/IN-VIO
1410699Jan 5, 2024UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINEMar 15, 2024IN VIOLATION
1735963Mar 14, 2022FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V3547567Jul 1, 2022IN VIOLATION
1735951Nov 29, 2021FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V3547567Mar 18, 2022IN VIOLATION
1735936Sep 28, 2021FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VJan 21, 2022IN VIOLATION
1735707May 8, 2021FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35475672Oct 1, 2021IN VIOLATION
1709478Mar 9, 2021FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VAug 13, 2021IN VIOLATION
1696277Mar 2, 2020FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. CONDITIONS:SLAug 13, 2021IN VIOLATION
1645959Feb 22, 2020FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED AT TIME OFAug 13, 2021IN VIOLATION
1709465Dec 23, 2019FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39012732May 14, 2021IN VIOLATION
1104676Dec 2, 2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, AT TIME OF INSPAug 13, 2021IN VIOLATION
1104529Nov 13, 2019FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT THE TIME OMay 14, 2021IN VIOLATION
1494514Oct 15, 201705A10,10E01.CEASE USE ITEM.DOOR ZONE RESTRICTOR INOPERATIVE REPAIR RESDec 22, 2017IN VIOLATION
1358143Mar 27, 201768B07,59BB05. 68B07-NEW UP TO DATE MAINTENANCE LOG NEEDED; 59BB05-EXPMay 19, 2017IN VIOLATION
372605Mar 27, 201768B07,59BB05. 68B07-NOW AND UP TO DATE MAINTENANCE LOG NEEDED; 59BB05May 19, 2017IN VIOLATION
936821Dec 13, 2011NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHOFeb 3, 2012IN VIOLATION
925366Dec 13, 2011LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIREMEFeb 3, 2012IN VIOLATION
918312Apr 18, 2011FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. SPALLING CEMENTJun 3, 2011STIPULATION/IN-VIO
775651May 15, 200958F10.03X10.03X10 CAR ENCLOSURE IN CAB CEILING FAN INOPERATIVENov 6, 2009IN VIOLATION
775608Apr 13, 200908V10.16L10.08V10 REPAIR ALL UP DIRECTIONAL FL STOPS 16L10 2ND AND 3RDJun 5, 2009IN VIOLATION
727887Feb 28, 200885U05,86U05.Apr 18, 2008IN VIOLATION
71882Feb 28, 200885U05,86U05.Apr 18, 2008IN VIOLATION
99436Jul 9, 200740D06,08V10,05L10,31H01.40-PROVIDE LOCK FOR DOOR.08-REPAIR FLOOR STOPSSep 7, 2007STIPULATION/IN-VIO
99428Jul 9, 200783X10,11X10,55Y13,39O02,59X10.11,83-ELEVATOR NOT RESPONDING TO CAR BUTSep 7, 2007STIPULATION/IN-VIO
503148Nov 2, 200683X16/ 83-X-16 RESTORE ELEVATOR BACK TO SERVICE SO THAT A PROPER INSPEDec 22, 2006STIPULATION/IN-VIO
464678Jun 23, 200434A,50A,50B,50C.50-INSTALL DISCHARGE PIPING ON SAFETY VALVES TO A SAFEAug 6, 2004IN VIOLATION
160873Nov 28, 1995USE OF RIGGING EQUIPMENT(SCAFFOLD)WITHOUT PROCEEDING(SAFETY BELTS).USEJan 26, 1996IN VIOLATION
154064May 31, 1995FAILURE TO MAINTAIN EXTERIOR BLDG WALL.DEFECT IS BRICK WORK + MASONARYJan 26, 1996IN VIOLATION
139620Aug 11, 19933M 3I 14L 21L 35P 3M CAPACITY PLATE 3I REPAIR VENTS BASE OF CAB WALL 1Oct 28, 1993IN VIOLATION
98114Aug 11, 19933M,3I,14L,21L,35P. 3 CAPACITY PLATE. 3 REPAIR VENTS BOTTOM OF CAB WALLNov 12, 1993IN VIOLATION
98779May 12, 19933M,21L,14I,36I,37Q,73U. 3 VENTS AT BOTTOM OF CAB. 21 HALL BUTTONS. 14 Aug 12, 1993IN VIOLATION