| 1387081 | Jan 14, 2026 | I OBSERVED NEW LIGHT FIXTURE INSTALL IN KITCHEN AREA FOR APARTMENT 106 | Feb 12, 2027 | PENDING | $1,250.00 |
| 390617 | Sep 2, 2025 | CLASS 2 ITEMS: IN-CAR COMMUNICATION EMERGENCY LIGHTING AND FAN INOPERA | Nov 7, 2025 | STIPULATION/IN-VIO | — |
| 1332954 | Sep 24, 2024 | RESPONDING, TO A ELEVATOR,IN ONE SECTION OF THE BUILDING. CEASE USE VI | Jan 31, 2025 | IN VIOLATION | — |
| 648352 | Mar 7, 2024 | RESPONDING TO A 311 ELEVATOR COMPLAINT, ONLY DEVICE IN THE BUILDING, U | May 17, 2024 | IN VIOLATION | — |
| 1530858 | Oct 19, 2022 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8C REPORT OF CRITICAL EXAM | Feb 3, 2023 | IN VIOLATION | $3,125.00 |
| 1701522 | Feb 23, 2022 | FAILURE TO MAINTAIN EXTERIOR BLDG FACADE&APPURTENANCES.(1)@W ELEVATION | Jun 24, 2022 | IN VIOLATION | — |
| 1685189 | Feb 13, 2020 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL E | May 14, 2021 | IN VIOLATION | — |
| 232626 | Apr 19, 2016 | 02L10,02X10,59E01,68B07,07X10,39O02,70O02,30O02,23L11,16K10. 02-ALARM | Jun 10, 2016 | IN VIOLATION | — |
| 1583104 | Sep 3, 2014 | FAILURE TO GROUND ELECTRICAL SYSTEMS. BSMT SERVICE GROUND CONDUCTOR: W | Feb 27, 2015 | IN VIOLATION | — |
| 1487437 | Sep 3, 2014 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS, | Oct 31, 2014 | Resolved | — |
| 1583111 | Sep 3, 2014 | FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION | Feb 27, 2015 | IN VIOLATION | — |
| 1583098 | Sep 3, 2014 | ELECTRICAL WORK W/O A PERMIT. GROUND FLOOR & BSMT: SUB PANEL BRANCH CI | Feb 27, 2015 | IN VIOLATION | — |
| 1583106 | Sep 3, 2014 | FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS. BSMT SERVICE SWITCHES: 2- | Feb 27, 2015 | IN VIOLATION | — |
| 884142 | Apr 23, 2010 | 16J10,20I11,40P16. 16J- FLOOR DOOR RUBBING. 20I- FLOOR DOOR VISION PAN | Aug 27, 2010 | IN VIOLATION | — |
| 95373 | Mar 13, 2007 | 16M11.ONLY DEVICE IN BLDG.MAKE ALL REPAIRS TO DEVICE SO A FULL INSPECT | May 4, 2007 | IN VIOLATION | — |
| 261123 | Jun 18, 2004 | CEASE USE,HAZARDOUS.52B10,40B10,83O02,51M07,85B05,83##,39M07,33M07,38M | Oct 22, 2004 | IN VIOLATION | — |
| 515844 | Sep 24, 2003 | 43H10/30P07/35Q03 #35 1900 BOXOF CAR COVERS | Oct 15, 2004 | IN VIOLATION | — |
| 376382 | Jul 25, 2003 | 83X10. #83 YOU MUST RETURN THIS DEVICE BACK IN SERVICE SO A PROPER INS | Mar 5, 2004 | IN VIOLATION | — |
| 376258 | Jul 22, 2003 | 83X10 - RESTORE TO SERVICE FOR A COMPLETE INSPECTION BY THIS DEPARTMEN | Oct 24, 2003 | IN VIOLATION | — |
| 376214 | Jul 22, 2003 | 83X10 - RESTORE TO SERVICE FOR A COMPLETE INSPECTION BY THIS DEPARTMEN | Oct 24, 2003 | IN VIOLATION | — |
| 451240 | Jul 7, 2003 | 66,O,2 44,Q,3 15,J,1 84,L,10 39,P,16 3 41 16 CRACKS CEASE USE UNTIL 3 | Jan 23, 2004 | IN VIOLATION | — |
| 366417 | Jul 7, 2003 | 66,O,2 34,Q,3 16,J,1 16,T,7 3, 41, 59,B,7 40,I,10 16 CHECKS CEASE USE | Jan 23, 2004 | IN VIOLATION | — |
| 273289 | Jan 2, 2001 | 73X11, 35P17. 73-RESTORE TO SERVICE FOR A COMPLETE INSPECTION BY ME | Feb 16, 2001 | IN VIOLATION | — |
| 297445 | Dec 11, 2000 | 75U05,60M07,74M07,53L11,62L11.60-SPRING BUFTER CTW SIDE 74-REINSTALL M | Feb 2, 2001 | IN VIOLATION | — |
| 297440 | Dec 11, 2000 | 75U05,48B15,46Q03. 46-REAR ROPE QUARD. | Feb 2, 2001 | IN VIOLATION | — |
| 320206 | Sep 5, 2000 | 55L11 57O02 74M07 36Q03 35O02 53L11 46Q03 15X11 15E01 17M07 74-TOE GU | Dec 22, 2000 | IN VIOLATION | — |
| 320221 | Sep 5, 2000 | 57O02 35O02 50Y11 36Q03 46Q03 15L11 15L01 55X11 36-DOOR LOCK 46-REAR | Dec 22, 2000 | IN VIOLATION | — |
| 320025 | Jul 17, 2000 | 73X11 15I11 36L11 15-BASEMENT 36-MOTORROOM 73-RESTORE TO SERVICE FOR A | Dec 22, 2000 | IN VIOLATION | — |
| 29418 | Mar 1, 2000 | 54R12,37G12,53L11,09H12,57O02,15I12,50W14.54- MAIN LINE FUSE 15- BASEM | Apr 14, 2000 | IN VIOLATION | — |
| 277268 | Feb 11, 2000 | 46H15,47H15,30O2,57O2,14M7,53X11,15B1,17M7. | Jun 23, 2000 | IN VIOLATION | — |
| 480276 | Dec 30, 1999 | FAILURE TO OBTAIN A PERMIT FOR SIDEWALK SHED ERETED IN FRONT COURT | Jun 9, 2000 | WRITTEN OFF | — |
| 252535 | May 17, 1999 | 17M12,30I11,35P17,57O2,57Z9,73N17,74L11. -17 5TH FLOOR, -30 FLOOR | Oct 13, 2000 | IN VIOLATION | — |
| 285986 | Sep 8, 1998 | WORK WITHOUT A TENT. WORK NOTED FILE APPLICATION FOR SHED AND NEVER | Apr 9, 1999 | IN VIOLATION | — |
| 494916 | Jan 8, 1998 | 53I,75U,50Y,35O,47M,54T,03O,30O,57O,74# 74 REPLACE FIRESERIVE KEY SWIT | Feb 27, 1998 | WRITTEN OFF | — |
| 494905 | Oct 10, 1997 | 75U,46M,50Y,35O,03O,57O,30O, | Feb 13, 1998 | WRITTEN OFF | — |
| 489499 | May 7, 1996 | 10X,5J,36W,46Q,55X,11R,50Y,74Y.10 OUTSIDE COMMUNICATION 5 GAP BACK OF | Jul 16, 1997 | WRITTEN OFF | — |
| 489489 | May 7, 1996 | 10X,5J,36W,46Q,17R,15R,55X,57O.10-OUTSIDE COMMUNICATION 5 GAP BACK OF | Apr 11, 1997 | WRITTEN OFF | — |
| 488221 | Aug 28, 1995 | 14M,17L,35W,57O,46K,74O. 17 REPLACE BROKEN VIDION GLASS NEEDED 74 CLEA | Nov 8, 1995 | WRITTEN OFF | — |
| 488262 | Aug 28, 1995 | 57O,74I,35O,35W,05B,15I. 74 REPAIR UPPER CAB VENTING. 05 REMOVE GAP WH | Nov 8, 1995 | WRITTEN OFF | — |
| 215122 | May 9, 1995 | FAILURE TO MAINTAIN DEFECT CRACKS FROM FIRST STORE TO TOP OF CHIMMNEY | Jul 28, 1995 | WRITTEN OFF | — |
| 194538 | May 5, 1995 | FAILURE TO MIANTAIN EXTERIOR BLDG WALL.DEFECT IS VERTICAL CRACKS FROM | Jul 28, 1995 | WRITTEN OFF | — |
| 487533 | Oct 18, 1994 | 14M, 17L, 35W, 57O, 58O, 59O, 46K, 74M, 74O, 74R. 17REPLACE BROKEN VIS | Mar 13, 1997 | WRITTEN OFF | — |
| 487525 | Oct 18, 1994 | 35P,57O,58O,59O,74I,74R 35PROVIDE ACCESS TO MOTOR ROOM 74REPAIR UPPER | Mar 13, 1997 | WRITTEN OFF | — |
| 487058 | May 25, 1994 | 35P,14M,09H,17M,15E,28H,(35)PROVIDE ACCESS TO MOTOR ROOM | Mar 13, 1997 | WRITTEN OFF | — |
| 487052 | May 25, 1994 | 35P,14M,09H,17M,15E,28H,(35)PROVIDE ACCESS TO MOTOR ROOM | Mar 13, 1997 | WRITTEN OFF | — |
| 484636 | Sep 3, 1993 | 14I 17M 17I 25R 37G 35O 35W 46K 50F 57O 58O 59O 74H 52L 74Q 53M 25 SEC | Nov 5, 1993 | WRITTEN OFF | — |
| 484635 | Sep 3, 1993 | 08V 37G 35W 35O 50Y 57O 35 PROPERLY FUSE CONTROLLER | Mar 13, 1997 | WRITTEN OFF | — |
| 482947 | Jan 13, 1993 | 01B,02X,35P,14I,74R. 01 WHEN STOP SWITCH ENGAGED ALARM MUST RING. | Mar 19, 1993 | WRITTEN OFF | — |
| 482935 | Jan 13, 1993 | 37G,37R,50Y,74M,74M. 37 PROVERLY FUSE CONTROLLER. 37 REMOVE JUMPER OF | Mar 13, 1997 | WRITTEN OFF | — |
| 394852 | May 21, 1992 | WORK WITHOUT A PERMIMT (NOTE) REMOVAL OF SECTION (APPROX 15' X 8') OF | Jul 24, 1992 | WRITTEN OFF | — |
| 150400 | Feb 21, 1992 | 43X,35P,57O,18M,14M,74O, 73- RESTORE ELEVATOR 2P1386 TO SERVICE FOR IN | Sep 24, 1992 | IN VIOLATION | — |
| 169806 | Jan 19, 1989 | WORK WITHOUT A PERMIT WORK NOTED: REMOVAL OF A SECTION OF BLOCK WALL I | Mar 3, 1989 | WRITTEN OFF | — |