| 1238164 | Aug 12, 2016 | 08V01,97X10. (08V)FLR STOPS EXCESSIBLY OFF LEVEL CAR STOPPING 3 TO 4 F | Dec 30, 2016 | DEFAULT | — |
| 1238273 | Aug 11, 2016 | 08V01. LEVELING IS OFF BY 2 FLR ON SOME FLOORS. ADJUST FLR LEVELING. | Dec 30, 2016 | DEFAULT | — |
| 1311585 | Nov 19, 2014 | 21L10,42M07,67X10,42E10,28H11,03V01,34Q13,33Q03. 21-BASEMENT INTERLOCK | Apr 24, 2015 | IN VIOLATION | — |
| 1080851 | Dec 4, 2013 | 10M07,67X10,68M07,58F10,56Y10,98BB05,45L10,05J10. 67-RESTORE EMERGENCY | Mar 14, 2014 | IN VIOLATION | — |
| 1189879 | Mar 27, 2013 | 3M7,5J1,10H11,16J1,26D6,98BB5,100I10. 3M7-COMMUNICATION, PROVIDE PHONE | Jul 26, 2013 | WRITTEN OFF | — |
| 1177092 | Sep 11, 2012 | 99BB05,98BB05,45H10,37D06,37I10,37X10,08V10,52K10,23L10,41I10,03I10,39 | Mar 8, 2013 | IN VIOLATION | — |
| 1509247 | Jun 11, 2012 | 52K11,21M07,16B01,40R09,41DP6,99M078,98M07,68M07. 52K- REPLACE RUSTED | Aug 24, 2012 | WRITTEN OFF | — |
| 1311117 | Mar 12, 2012 | 52K11,72M7,100M7,8V1,16B1,21Q3,12Q3,98BB5,99B5,68M7: 100;PHONE IN CAR | Aug 17, 2012 | IN VIOLATION | — |
| 1300382 | Jan 12, 2010 | 08V10,44H10,52H11,56Y13,56O02,30M07,32H10. 08V- ADJUST FL STOPS WERE | Mar 5, 2010 | WRITTEN OFF | — |
| 1229381 | Oct 6, 2008 | 26D10.05J10.10H10.16L10.08V10.21Q03.16D10.100BB05.16L10.21L10. CU 26D1 | Dec 19, 2008 | WRITTEN OFF | — |
| 1203150 | Jun 13, 2008 | 8V1.83L10.32H10.27H10.16L10.39P7. 8V LEVELING IS OFF 83L NOISE IN HOIS | Sep 26, 2008 | WRITTEN OFF | — |
| 1097017 | Jan 12, 2007 | 83X10,39P16,36P10. 83-REPAIR,RESTORE & PROVIDE SERVICE | Apr 20, 2007 | WRITTEN OFF | — |
| 576577 | Jul 13, 2005 | WORK WITHOUT A PERMIT.WORK NOTED:REMOVED ALL THE FIRE RATED MATERIAL A | Nov 18, 2005 | IN VIOLATION | — |
| 469013 | Sep 19, 2003 | 03I10/31H10/36P07/09I10/21Q03 #03 WALLS STAINLESS WITH SHARP EDGES | Jan 21, 2005 | WRITTEN OFF | — |
| 259216 | Sep 18, 1999 | 3D6,8V1,28B1,22D6,11M7,57O2,74M7,34H12,18M7,75U5. -3 PROPERLY SECURE | Nov 12, 1999 | STIPULATION/IN-VIO | — |
| 774849 | Jun 16, 1998 | 73X11,17A1231Q03,73## #17A12= VISION PANEL MUST BE WIRE GLASS. #73X11 | Dec 11, 1998 | WRITTEN OFF | — |
| 494223 | Aug 5, 1997 | 73X 73. RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY | Apr 10, 1998 | WRITTEN OFF | — |
| 309917 | Apr 8, 1996 | 57O,73X.73-RETURN TO SERVICE SO A PROPER INSPECTION CAN BE DONE BY THI | Aug 9, 1996 | WRITTEN OFF | — |
| 309663 | Jul 15, 1994 | 73X,14M,35P,57O,7O,73-RESTORE ELEV. TO SERVICE. 35. PROVIDE ACCESS TO | Dec 16, 1994 | WRITTEN OFF | — |
| 309423 | Sep 30, 1993 | 17M,17M,18M,15B,22D. 17 REPLACE MISSING PANEL GALSS AND GUARDS NECESS- | Nov 26, 1993 | WRITTEN OFF | — |
| 480012 | Mar 26, 1992 | 73#,36W,11Q,28H,33O,33I,15J, 73. PERFORM 5 YR TEST PROPERLY TAG DEVICE | Nov 6, 1992 | WRITTEN OFF | — |
| 473898 | Jun 26, 1991 | 36W,50Y,37M,17M35O,11Q,18Q,31D,31Q,25Q,28H,5J,22R,73#,33W,40I,33I,33R, | Aug 9, 1991 | WRITTEN OFF | — |