OpenViolations
/

1451 Crotona Place

BronxBIN 2009638
1 open Class CHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
1
Immediately hazardous
Open Class B
4
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
8
DOB permit records
Last activity
Dec 4, 2025
Bedbugs record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

B
Health score · Jul 29, 2026
Scored from all 75 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 1
Open Class B violations
Hazardous
This building 4
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 75 records on file.

Download this timeline (CSV) →
Dec 4, 2025
Dec 18, 2024
Aug 7, 2024
Aug 1, 2024
Jul 5, 2024
Dec 1, 2023
Jun 20, 2023
Dec 6, 2022
Dec 2, 2021
Jul 19, 2021
Jul 16, 2021
Apr 5, 2021
Mar 3, 2021
Jun 12, 2020
Jun 12, 2020
May 1, 2020
Jan 30, 2020
Apr 3, 2019
Feb 15, 2019
Jan 24, 2019
Jan 3, 2019
Oct 15, 2018
Jul 31, 2018
Jun 15, 2018
Jun 15, 2018
Jun 15, 2018
Jun 15, 2018
Jun 15, 2018
Aug 29, 2017
Aug 29, 2017

OATH / ECB summonses & fines

No balance is recorded as due across the 16 summonses below, out of $45,592.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 1451 Crotona Place
1321173Jun 12, 2020FAILURE TO POST PERMIT FOR EQUIPMENT AT TIME OF MY INSPECTION OF A 6 SAug 21, 2020IN VIOLATION
1374049Jan 3, 2019FAILURE TO TAKE REQUIRED MEASURES TO PROTECT PUBLIC FROM DOCUMENTED UNMar 15, 2019ADMIT/IN-VIO
796950Oct 15, 2018FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXMINATION DOApr 19, 2019IN VIOLATION
996632Aug 1, 2013LICENCSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIRE-Sep 20, 2013IN VIOLATION
942314Aug 1, 20133314.3.1.6 WHERE PARAPET CLAMPS ARE USED TO SUPPORT A VERTICAL LOAD, Sep 20, 2013IN VIOLATION
996412Apr 15, 20133314 PARTIAL *SWO* SUPPORTED SCAFFOLD DOES NOT MEET DOB SPECIFICATIONSJun 28, 2013IN VIOLATION
1258366Jun 11, 2012FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEAug 31, 2012IN VIOLATION
957519May 9, 2012SEC. 28-302.5. FAILURE TO PROTECT THE PUBLIC BY PROVIDING SAFETY MEASUJun 29, 2012STIPULATION/IN-VIO
1045408May 9, 2012FAILURE TO MAINTAIN AND APPURTENANCES. NOTED: AT FACADE AC UNITS ARE Jun 29, 2012STIPULATION/IN-VIO
983579Jan 15, 2012FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEJun 13, 2012IN VIOLATION
1258252Apr 15, 2011FAIL TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE W/Aug 30, 2011IN VIOLATION
770946Jul 15, 2010FAIL TO MAINTAIN BLDG WALLS & APPURTENANCES. 1) FRONT FACADE (OVER RAMNov 19, 2010IN VIOLATION
5247Jul 15, 2010FAIL TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANCE Apr 1, 2011IN VIOLATION
1258247Jul 12, 2010FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCENov 5, 2010IN VIOLATION
1211608Nov 27, 2009FAILURE TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANFeb 19, 2010WRITTEN OFF