OpenViolations
/

1930 Anthony Avenue

BronxBIN 2007765
9 open Class CHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
9
Immediately hazardous
Open Class B
29
Hazardous
Open Class A
5
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
0
DOB permit records
Last activity
May 21, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

F
Health score · Jul 29, 2026
Scored from all 264 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 9
Open Class B violations
Hazardous
This building 29
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 5
Tenant litigation
Open HP actions in Housing Court
This building 2
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 264 records on file.

Download this timeline (CSV) →
May 21, 2026
Mar 5, 2026
Feb 24, 2026
Feb 17, 2026
Feb 5, 2025
Dec 19, 2024
Dec 11, 2024
Nov 26, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 16, 2024
Oct 11, 2024
Jul 30, 2024
Jun 3, 2024
May 24, 2024
May 15, 2024
May 15, 2024
May 15, 2024
May 15, 2024
May 15, 2024
May 15, 2024
May 15, 2024

OATH / ECB summonses & fines

No balance is recorded as due across the 11 summonses below, out of $10,000.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 1930 Anthony Avenue
1747380Nov 26, 2024IN APARTMENT 3B OBSERVED FLOOR AREA (APPRX. 15 INCH BY15 INCH)SINKAGE Sep 29, 2025ADMIT/IN-VIO
580455Jul 26, 201108V01,37T07,39O02,56Y13,59H11,70O02,70Z02,71X10,77B11,98U15. 37T07- PRSep 16, 2011STIPULATION/IN-VIO
483316Feb 13, 200883X10. 83X10 1 RCNY 11-02 ONLY ELEVATOR IN BLDG OUT OF SERVICE, RESTORMay 5, 2008IN VIOLATION
854685Jul 25, 200785U5/36O6/38O2/28Q3/8V10/66Z10/66O2/55Y10/CU:1R11/CU:21L10/CU:16L10/.6Dec 7, 2007DEFAULT
482738Mar 8, 200620I11/5I11/5B10/5B1/33L10/20L10/66O2/39P7/85M5/CU 21B10/40B11. 40/B MAOct 27, 2006IN VIOLATION
139252Sep 25, 199514M,18Q,53M,54G,57O,75#,. 75 PERFORM 5 YEAR TEST, PROPERLY TAG DEVICE Dec 8, 1995STIPULATION/IN-VIO
478723Dec 14, 199473X. 73-RESORE ELEVATOR SEVICE SO PROPER INSPECTION CAN BE MADE BY Mar 24, 1995WRITTEN OFF
477957Jan 29, 199302L,12Q,17M,28H,35O,33P,57O,73L,(17)REPL HATCH DOOR GLAS WHERE NEEDED Apr 16, 1993WRITTEN OFF
477879Jan 29, 199302L 11Q 13M 08V 33P 35O 57O 08 CAR STOPS BETWEEN FLOORSApr 9, 1993WRITTEN OFF
477741May 5, 199235P,73X,(35)PROVIDE ACCESS TO MOTOR ROOM.(73)RESTORE TO SERVICE.Jul 10, 1992WRITTEN OFF
475370Jul 2, 199173X,57O,74O,74H,13M,73 - RESTORE ELEVATOR TO SERVICE SO A PROPER INSPEOct 25, 1991WRITTEN OFF