| 1078900 | Apr 8, 2025 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL E | Jul 18, 2025 | IN VIOLATION | — |
| 1744499 | Oct 15, 2024 | ADJUST FLOOR STOPS. PROVIDE IN CASE OF FIRE SIGN IN LOBBY. MISALIGNED | Dec 20, 2024 | IN VIOLATION | — |
| 1703141 | Sep 19, 2024 | 3307.6.4.8 LIGHTING. AT A OCCUPIED BUILDING WITH SIDEWALK SHED I NOTIC | Feb 14, 2025 | IN VIOLATION | — |
| 1433124 | Nov 8, 2019 | I OBSERVED IN THE BASEMENT AREA OF THE LAUNDRY ROOM, FOUR GAS DRYERS I | Jan 3, 2020 | IN VIOLATION | — |
| 1433118 | Nov 8, 2019 | I OBSERVED IN THE BASEMENT AREA OF THE LAUNDRY ROOM, FOUR GAS DRYERS I | Jan 3, 2020 | IN VIOLATION | — |
| 1433088 | Nov 8, 2019 | I OBSERVED IN THE BASEMENT AREA OF THE LAUNDRY ROOM, FOUR GAS DRYERS I | Jan 3, 2020 | IN VIOLATION | — |
| 1433096 | Nov 8, 2019 | I OBSERVED IN THE BASEMENT AREA OF THE LAUNDRY ROOM, FOUR GAS DRYERS I | Jan 3, 2020 | IN VIOLATION | — |
| 1470381 | Jul 26, 2019 | WORK WITHOUT A PERMIT I OBSERVED ON LOBBY FLOOR GAS PIPING WITH GAS V | Apr 24, 2020 | IN VIOLATION | — |
| 1470382 | Jul 26, 2019 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED I OBSERVED ON L | Apr 24, 2020 | IN VIOLATION | — |
| 1470380 | Jul 26, 2019 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER I OBSERVED ON TH | Apr 24, 2020 | IN VIOLATION | — |
| 1413071 | Jan 25, 2019 | BC 3314.1 FAILURE TO MAINTAIN SUPPORTED SCAFFOLD IN CODE COMPLIANT MAN | Mar 29, 2019 | IN VIOLATION | — |
| 1305652 | Mar 16, 2012 | 03M11,24X10,68B07,70O02: 03M11;REPLACE HAND RAIL IN CAR. 24X10;REPAIR | May 4, 2012 | DEFAULT | — |
| 358807 | Oct 19, 2009 | 32H10.70O2.39O2.40P16.32H10 TOP AND BOTTOM CAR GUIDE SHOES ARE WORN 40 | Dec 18, 2009 | DEFAULT | — |
| 358818 | Oct 19, 2009 | 32H10.70O2.40P16 32H10 TOP AND BOTTOM CAR GUIDE SHOES ARE WORN 40P16 P | Dec 18, 2009 | DEFAULT | — |
| 357807 | Jul 1, 2009 | CU100L10 60Q03 68M07 69M07 81M07 98BB05 CEASE USE ITEM 100L10 REPAIR E | Aug 21, 2009 | DEFAULT | — |
| 1105772 | Jul 1, 2009 | CUI 100L10.40D6.60Q3.68M7.69M7.98BB5 CUI 100L10 REPAIR ELEVATOR SO THA | Aug 21, 2009 | DEFAULT | — |
| 1105769 | Apr 25, 2008 | 24X10,34Q03,35Q03,58Q03,51M07,59X10,71Q03,85BB05,86BB05.24X10-REPAIR P | Jun 13, 2008 | DEFAULT | — |
| 865403 | Apr 25, 2008 | 24X10,34Q03,35Q03,38Q03,59X10,59Q03,71Q03,85BB05,86BB05.24X10-REPAIR H | Dec 8, 2008 | IN VIOLATION | — |
| 1105729 | Nov 8, 2006 | EXIT DOORS TOTAL OBSTRUCTION NOTED:EXIT DOORS AT 1ST FLR AT 167 STREET | Mar 2, 2007 | DEFAULT | — |
| 320534 | Nov 8, 2006 | EXIT DOOR TOTAL OBSTRUCTION NOTED:EXIT DOOR ON THE EAST SIDE OF PREMIS | Mar 2, 2007 | DEFAULT | — |
| 320161 | Oct 14, 2006 | EXIT DOOR TOTAL OBSTRUCTION NOTE:EMERGENCY EXIT DOOR ON THE EAST SIDE | Jan 5, 2007 | DEFAULT | — |
| 679956 | Jul 20, 2006 | EXIT DOORS TOTAL OBSTRUCTION.EXIT DOORS AT 1ST FL AT 167 ST & LEADING | Oct 6, 2006 | WRITTEN OFF | — |
| 679927 | Jul 20, 2006 | EXIT DOOR, TOTAL OBSTRUCTION. EXIT DOOR ON THE EAST SIDE OF PREMISES H | Oct 6, 2006 | WRITTEN OFF | — |
| 1062020 | Jun 9, 2006 | EXIT DOOR TOTAL OBSTRUCTION. THE EMERGENCY EXIT DOOR OF THE CAST SIDE | Sep 22, 2006 | WRITTEN OFF | — |
| 1031907 | Mar 27, 2006 | EXIT DOOR OBSTRUCTION. EXIT DOOR ON THE EASTSIDE OF PREMISES HAS BEEN | May 19, 2006 | WRITTEN OFF | — |
| 1031951 | Mar 23, 2006 | EXIT DOOR- TOTAL OBSTRUCTION. EXIT DOOR AT FIRST (1ST) FL LEADING TO G | May 5, 2006 | WRITTEN OFF | — |
| 944542 | Jan 29, 2006 | EXIT DOOR TOTAL OBSTRUCTION NOTED: EMERGENCY EXIT DOOR EAST SIDE OF BL | Mar 17, 2006 | WRITTEN OFF | — |
| 704062 | May 5, 2004 | FAILURE TO MAINTAIN PLUMBING AND / OR APPURTENCES SEWER STOPPED UP CAU | Jun 18, 2004 | WRITTEN OFF | — |
| 0126133270 | Sep 9, 2002 | FAILURE TO SWEEP 18 INCHES FROM CURB | Oct 8, 2002 | WRITTEN OFF | — |
| 814499 | Aug 14, 2001 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED / AT N/WEST CORNER PA | Nov 2, 2001 | WRITTEN OFF | — |
| 749329 | Jul 10, 2001 | 5702/ 36P17/ 9H12/ 46H12/ 30O2/ 28H12/ | Aug 24, 2001 | WRITTEN OFF | — |
| 479942 | Sep 30, 1999 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: FIRE ESCAPE BOT | Nov 12, 1999 | WRITTEN OFF | — |
| 478504 | Jul 1, 1999 | FAILUR ETO MAINTAIN EXTERIOR BLDG WALL DEFECT IS AT SOUTH WEST CORNER | Aug 27, 1999 | WRITTEN OFF | — |
| 217836 | Aug 25, 1998 | WORK WITHOUT A PERMIT. WORK NOTED: REPLACING LINTELS ON EAST FACADE | Oct 9, 1998 | IN VIOLATION | — |
| 928695 | Aug 24, 1998 | WORK WITHOUT A PERMIT. REPLACING STEEL LINTELS ON NORTH FACADE. | Oct 9, 1998 | WRITTEN OFF | — |
| 958120 | Aug 18, 1998 | NO SIDEWALK SHED. REPLACING STEEL LINTELS OVER 40' ABOVE SIDEWALK ON | May 12, 2000 | WRITTEN OFF | — |
| 514612 | Feb 13, 1998 | 57O2,3O2,32Q3,31D6,54B7,74L11,37U16,50U16,54U16,40R7,22R7,36T7,21X11, | Jul 10, 1998 | WRITTEN OFF | — |
| 514605 | Feb 13, 1998 | 57O2,31D6,22R12,28H11,32Q6,37U16,50U16,54U16,40R7,36T7,21X11,21I11, | Jul 10, 1998 | WRITTEN OFF | — |
| 514486 | Oct 18, 1997 | 3I20B22D28H30O35P55M57O75U NOT WORKING ON SOME FLOORS 22-EMS EXIT NOT | Jul 10, 1998 | WRITTEN OFF | — |
| 514478 | Oct 18, 1997 | 3L20L2122D28H31M32M35P55M57O75U 27-GLASS BROKEN INDICATOR 22-REPLACE | Jul 10, 1998 | WRITTEN OFF | — |
| 734581 | Dec 19, 1996 | EXIT DOOR TOTAL OBSTRUCTION THE EAST BUILDING EGRESS/INGRESS DOOR HAS | Jan 24, 1997 | WRITTEN OFF | — |
| 981381 | May 11, 1995 | FAILURE TO MAINTAIN.DEFECT NOTED:EXTERIOR BRICKWORK DEFECTIVE,DIAGNOL | Sep 8, 1995 | WRITTEN OFF | — |
| 215093 | May 1, 1995 | FAILURE TO MAINTAIN.DEFECT NOTED.VERTICAL CRACKS THRU-OUT WALL FRONT | Sep 8, 1995 | WRITTEN OFF | — |
| 484518 | Sep 9, 1993 | 73R 37R 25R 73 FILE APPLICATION 7 OBTAIN PERMIT FILE BN WITH THIS EPT | Dec 10, 1993 | WRITTEN OFF | — |
| 484507 | Sep 9, 1993 | 73R 18 R 37R 25R 73 FILE APPLICATION & OBTAIN PERMIT FILE BN FOR NEW C | Nov 5, 1993 | WRITTEN OFF | — |