| 344205 | Feb 22, 2022 | FOUND CORROSION ON MANIFOLD NEED TO BE CHECKED OR REPLACE. | Aug 19, 2022 | IN VIOLATION | $500.00 |
| 1687280 | Feb 22, 2022 | FOUND SAFETY LEAKING ON BOILER. REPLACE SAFETY. | Aug 19, 2022 | IN VIOLATION | $500.00 |
| 1201456 | Jun 12, 2020 | REPAIR PHONE., PROVIDE KEYS ACCESS TO NORTH SIDE HOIST WAY DOORS., REP | Jul 31, 2020 | DEFAULT | $3,125.00 |
| 1731574 | Jun 12, 2020 | REPAIR PHONE., PROVIDE KEYS ACCESS TO NORTH SIDE HOIST WAY DOORS., REP | Jul 31, 2020 | DEFAULT | $1,562.00 |
| 1158693 | Sep 8, 2019 | (16N10,71X10,29M7,39X10,26B11,2X10)16W#FLOOR 5S DEIVICE IS NOT SERVICI | Nov 1, 2019 | ADMIT/IN-VIO | — |
| 1665949 | Jul 10, 2019 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOL | Jul 10, 2020 | IN VIOLATION | — |
| 1517455 | Jun 14, 2019 | 42B07,02X10,57B111,61T07,40O02,24I10,39D06,45M07,71X10,53U07,72T07,39X | Sep 13, 2019 | IN VIOLATION | — |
| 1464267 | May 21, 2019 | RTS-97X10; 40B09,57B11,42I10. 97X10-RETURN TO SERVICE. THE ONLY DEV | Nov 8, 2019 | IN VIOLATION | $3,125.00 |
| 1168875 | May 7, 2019 | 97.X.17,42.B.10,40.B.09,57.BB.11,42.D.06;(97.X.17) ONLY DEVICE ON THE | Nov 22, 2019 | IN VIOLATION | $3,125.00 |
| 446700 | Jan 15, 2019 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLA | May 24, 2019 | IN VIOLATION | — |
| 1624556 | Jan 4, 2019 | (97,X,17)RETURN ELEVATOR DEVICE TO SERVICE AND FILE TEST. | Mar 1, 2019 | IN VIOLATION | — |
| 1624523 | Sep 23, 2018 | 24X10,70Z09. 24-INDICATORS INOPERATIVE REPAIR; 70-PIT WATER LEAK IN P | Nov 16, 2018 | STIPULATION/IN-VIO | — |
| 1438373 | Aug 29, 2018 | 97X17,100Z04. 97X17 RTS RESTORE TO SERVICE AND FILE FOR INSPECTION; | Oct 19, 2018 | IN VIOLATION | — |
| 1393840 | Mar 13, 2018 | 25M07,15M07,64M07,67X10,31V10,70M07. 25M07-NO MOTOR ROOM SIGNAGE. | May 4, 2018 | STIPULATION/IN-VIO | — |
| 1393793 | Dec 2, 2015 | 02X10,40M07. PROVIDE KEYS FOR 40-MACHINE ROOM; 50A COMPLETE INSPECTIO | Jan 29, 2016 | DEFAULT | — |
| 1438308 | May 23, 2014 | 39Y02,48Y13,53B14,42G11,67X10.39-Y-02 CLEAN OIL FROM CAR TOP 48-Y-13 S | Sep 5, 2014 | IN VIOLATION | — |
| 683204 | Apr 22, 2009 | FAILED TO NOTIFY DEPT OBTAIN PERMIT PRIOR TO USE INST. OUTRIGGER BEAMS | Nov 27, 2009 | IN VIOLATION | — |
| 759517 | Jan 31, 2009 | SIDEWALK SHED DOES NOT CONFORM/MEET CODE SPECIFICATIONS. SIDEWALK SHED | Apr 3, 2009 | IN VIOLATION | — |
| 196488 | Nov 10, 1997 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DECORATIVE MASONAY OVER | Mar 27, 1998 | IN VIOLATION | — |
| 42504 | Jan 4, 1995 | FAILURE TO MAINTAIN EXTERIOR WALL. DEFECT IS BROKEN, DEFECTIVE STEEL | Apr 7, 1995 | IN VIOLATION | — |
| 157415 | Oct 28, 1993 | FAILURE TO MAINTAIN SIDE WALL HAS PARTIALLY COLLAPSED ON WILLIS AVE - | Feb 24, 1994 | IN VIOLATION | — |
| 178807 | Mar 5, 1991 | FAILURE TO MAINTAIN EXTERIOR BLDG WALL DEFECT IS BROKEN & DEFECTIVE | Jun 21, 1991 | WRITTEN OFF | — |