| 1650626 | Apr 11, 2022 | 37-727 MISC V ON AS OF RIGHT PRIVATELY OWNED PUBLIC SPACE.AS PER POPS | Mar 16, 2023 | IN VIOLATION | — |
| 1486315 | May 11, 2021 | FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN.NOTE:AT TIME OF | Jul 29, 2021 | IN VIOLATION | — |
| 1486418 | May 11, 2021 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE:AT | Jul 29, 2021 | IN VIOLATION | — |
| 1127005 | May 19, 2020 | ACTIVE CONSTRUCTION OCCURRING AT A NONESSENTIAL CONSTRUCTION SITE:AT T | Jul 15, 2021 | IN VIOLATION | — |
| 545871 | Aug 28, 2014 | FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN | Oct 30, 2014 | IN VIOLATION | — |
| 1014383 | Aug 28, 2014 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE APT 9K: BRANCH CIRCUIT WIRING | Oct 30, 2014 | IN VIOLATION | — |
| 959830 | Jan 24, 2014 | FAILURE TO MAINTAIN BLDG CODE COMPLIANT: NO FIRE STOPPING PER BC712.3; | Mar 13, 2014 | IN VIOLATION | — |
| 722889 | Jan 24, 2014 | FAILURE TO MAINTAIN BLDG CODE COMPLIANT: LACK OF EMERGENCY LIGHTING FO | Mar 13, 2014 | IN VIOLATION | — |
| 722891 | Jan 24, 2014 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: AT GARAGE, SUB | Mar 13, 2014 | IN VIOLATION | — |
| 931019 | Nov 25, 2011 | FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER USE OF PROHIBITED DOOR HA | Jan 12, 2012 | ADMIT/IN-VIO | — |
| 430964 | Apr 23, 2008 | STOP WORK ORDER ISSUED NO.531 NO RECORD OF DAILY INSPECTION OF SUSPEND | Jan 8, 2009 | IN VIOLATION | — |
| 736171 | May 23, 2007 | FAILURE TO MAINTAIN EXTERIOR OF BLDG. CONCRETE SPALLINGS WERE FOUND AT | Jul 12, 2007 | IN VIOLATION | — |
| 399275 | Jan 15, 2003 | 41H11-80U07-08B11-37D09-26B01-30B07-29I07. 41-REPAIR OR REPLACE WORN D | Mar 6, 2003 | STIPULATION/IN-VIO | — |
| 332742 | May 3, 2001 | 75/U/16 3 YEAR TEST TAG MISSING PERFORM TEST + TAG DEVICE | Jun 21, 2001 | IN VIOLATION | — |
| 326786 | Jun 7, 2000 | 43B16,10I10. 43- PERFORM REQUIRED PERIODIC PRESSURE TESTS. 10+- RENEW | Dec 14, 2000 | IN VIOLATION | — |
| 240998 | Jun 5, 2000 | 75R05,02B11,01B07. 75- PERFORM REQUIRED 5 YEAR TEST. 02- REPAIR PHONE | Oct 19, 2000 | IN VIOLATION | — |
| 240957 | Jun 5, 2000 | 75R05. 02B11. 75- PERFORM REQUIRED 5 YEAR TESTS. 02- REPAIR PHONE IN | Oct 19, 2000 | IN VIOLATION | — |
| 275811 | May 5, 2000 | 75R05,02B11. 75- PERFORM REQUIRED FIVE YEAR TESTS. 02- REPAIR PHONE IN | Aug 24, 2000 | STIPULATION/IN-VIO | — |
| 305488 | Apr 10, 2000 | OPERATION OF HOISTING EQUIPMENT IN AN UNSAFE MANNER A-OUTRIGGER BEAMS | Aug 10, 2000 | IN VIOLATION | — |
| 181100 | Aug 24, 1998 | WORK WITHOUT PERMIT AT TIME OF INSPECTION NEW PLUMBING WORK HAS BEEN D | Nov 12, 1998 | STIPULATION/IN-VIO | — |
| 125968 | Jun 27, 1996 | INSTALLATION OF MECHANICAL EQUIPMENT WITHOUT FIRST OBTAINING AN EQUIPM | Aug 15, 1996 | STIPULATION/IN-VIO | — |
| 145092 | May 2, 1996 | FAILURE TO MAITNAIN EXTERIOR BUILDING WALL DEPT IS ST 22ND FLR APPROX | Jul 11, 1996 | IN VIOLATION | — |
| 167557 | Sep 29, 1995 | OPERATION PLACE OF ASSEMBLY CONTRARY TO THE CERTIFICATE OF OCCUPANCY W | Nov 16, 1995 | STIPULATION/IN-VIO | — |
| 167394 | Sep 29, 1995 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY # 1 | Nov 16, 1995 | STIPULATION/IN-VIO | — |
| 132807 | Sep 29, 1995 | WORK WITHOUT A PERMIT: WORK NOTED (1) INSTALLATION OF PARTITION WALLS | Nov 16, 1995 | IN VIOLATION | — |