Open Class C
0
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
58
DOB permit records
Last activity
May 19, 2026
DOB record
Building health score
A composite of public indicators. Every input is a public record. See the full methodology.
A
Health score · Jul 29, 2026
Scored from the 300 most recent of 478 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 4
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No
Unified timeline
Records from every agency, interleaved. Showing the 300 most recent of 478 records on file; the CSV below has the full history.
May 19, 2026
Feb 25, 2026
Dec 29, 2025
Dec 19, 2025
Dec 2, 2025
Jul 12, 2025
Dec 6, 2024
Nov 6, 2024
Nov 5, 2024
Aug 16, 2024
Jul 15, 2024
Jul 15, 2024
Jul 15, 2024
Apr 19, 2024
Apr 1, 2024
Apr 1, 2024
Mar 25, 2024
Dec 13, 2023
Oct 2, 2023
Sep 15, 2023
Sep 15, 2023
Sep 15, 2023
Sep 15, 2023
Sep 15, 2023
Sep 5, 2023
Aug 9, 2023
Aug 9, 2023
Aug 9, 2023
Jul 18, 2023
Jul 16, 2023
OATH / ECB summonses & fines
No balance is recorded as due across the 64 summonses below, out of $92,865.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.
| 1732576 | Nov 6, 2024 | ATOI OBSERVED EXHAUST VENTING FROM STOVE TO SIDEWALK AND NOT TO ROOF . | Jan 16, 2025 | ADMIT/IN-VIO | — |
| 1687125 | Aug 9, 2023 | OBSERVED SUSPENDED SCAFFOLDING INSTALLED AT ROOF LEVEL OF JOBSITE AT E | Oct 19, 2023 | IN VIOLATION | — |
| 1687124 | Aug 9, 2023 | OBSERVED SUSPENDED SCAFFOLDING INSTALLED AT ROOF LEVEL OF JOBSITE AT E | Oct 19, 2023 | IN VIOLATION | — |
| 1206277 | Sep 17, 2022 | SUSPENDED SCAFFOLD INSTALLED CONTRARY TO APPROVED:SUPPORT AT THE FRON | Apr 27, 2023 | IN VIOLATION | — |
| 1222512 | Sep 17, 2022 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV | Jan 5, 2023 | IN VIOLATION | — |
| 866873 | Dec 18, 2019 | (C/U 05A10);(C/U 59X10),52B14,68B07,59B07,70O02,16H01,16I10:05-A-10 CE | Feb 27, 2020 | IN VIOLATION | — |
| 672238 | Dec 19, 2018 | 3314.4.1.5 FAILURE TO NOTIFY DEPARTMENT 24-48 HOUSE BEFORE INSTALLATIO | Apr 4, 2019 | Resolved | — |
| 1398456 | Nov 29, 2018 | 5A10,70O02,71L10,73H11-5A10)CEASE USE ITEM, DOOR ZONE RESTRICTOR HAS B | Jan 24, 2019 | IN VIOLATION | — |
| 1368158 | Jan 31, 2018 | 02X10,06B10,16D06,21M07.02X 2 WAY COMMUNICATIONS INOPERABLE(OUTSIDE CO | Mar 22, 2018 | IN VIOLATION | — |
| 1314127 | Nov 27, 2017 | 02X10;03J10;97X10:2-WAY COMMUNICATION-INOPERABLE;ELEVATORS GIFTS WHEN | Jan 11, 2018 | IN VIOLATION | — |
| 012064901N | May 25, 2017 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Jul 19, 2017 | IN VIOLATION | — |
| 1002769 | Mar 23, 2017 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE. AT TIME OF INS | Aug 17, 2017 | IN VIOLATION | — |
| 862949 | Mar 16, 2017 | 05B10,52B14,70O02. 05-CAR DOOR RESTRICTOR INSUFFICIENT REPAIR; 52-HOI | May 4, 2017 | IN VIOLATION | — |
| 170297 | Feb 3, 2017 | 97X10 RESTORE TO SERVICE IMMEDIATELY. | Mar 23, 2017 | ADMIT/IN-VIO | — |
| 012061274J | Jan 24, 2017 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Mar 15, 2017 | IN VIOLATION | — |
| 1133551 | Jan 20, 2017 | 54E17 COUNTERWEIGHT WEDGE SHACKLE IS RUBBING AGAINST HOISTWAY WALL | Mar 9, 2017 | IN VIOLATION | — |
| 012056303N | Aug 23, 2016 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Oct 12, 2016 | IN VIOLATION | — |
| 012053707X | May 31, 2016 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Jul 20, 2016 | IN VIOLATION | — |
| 012050669K | Feb 4, 2016 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Mar 23, 2016 | IN VIOLATION | — |
| 012050416M | Jan 26, 2016 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Mar 16, 2016 | IN VIOLATION | — |
| 1111762 | Dec 23, 2015 | 23X10 HALL BUTTON STATION INOPERATIVE ELEVATOR GETS STUCK OR FLOORS | Feb 11, 2016 | IN VIOLATION | — |
| 012047998Y | Oct 27, 2015 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Dec 17, 2015 | IN VIOLATION | — |
| 1145085 | Oct 21, 2015 | 61T07,67B01,16J01,32H11,56Y13,56Y02,07L10. 61T07-PROVIDE COMPANY STICK | Dec 10, 2015 | IN VIOLATION | — |
| 681999 | Oct 21, 2015 | 16J01,29L10,32H11,56Y13,56Y02,07L10,61T07,67B01. 16J01-ADJUST BASEMENT | Dec 10, 2015 | STIPULATION/IN-VIO | — |
| 012046050P | Aug 26, 2015 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Oct 14, 2015 | IN VIOLATION | — |
| 1158389 | Jul 20, 2015 | 11X10,37M07,39O02,56Y13,59Y10,71X10. 11X-10TH FLR NOT STOPPING WHEN GO | Sep 3, 2015 | IN VIOLATION | — |
| 1144270 | Jul 20, 2015 | 21B06,10D06,42B09,56Y13,59Y02. 21B-BASEMENT (KEEPER) PARTIAL VIEW OF | Sep 3, 2015 | STIPULATION/IN-VIO | — |
| 012040401K | Feb 5, 2015 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Mar 25, 2015 | IN VIOLATION | — |
| 012036192L | Aug 20, 2014 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Oct 8, 2014 | IN VIOLATION | — |
| 012033876Z | May 27, 2014 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Jul 16, 2014 | IN VIOLATION | — |
| 012031467Z | Mar 6, 2014 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Apr 23, 2014 | IN VIOLATION | — |
| 012030498R | Jan 30, 2014 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Mar 19, 2014 | DEFAULTED | — |
| 012027130L | Sep 25, 2013 | FIRE PROTECTION SYSTEMS:FAIL TO PREVENT UNNECESSARY UNWARRANTED ALARMS | Nov 13, 2013 | DEFAULTED | — |
| 1016995 | Jan 30, 2013 | 100B10 - CAR #1P10299 DOES NOT STOP ON ANY FLOOR GOING UP ONLY DOWN AL | Jun 13, 2013 | IN VIOLATION | — |
| 1053598 | Oct 12, 2012 | 97X10- DEVICE INOPERATIVE. RESTORE TO SERVICE FOR A COMPLETE INSPECTIO | Nov 29, 2012 | STIPULATION/IN-VIO | — |
| 950650 | Dec 6, 2011 | (42G11),(77B11),(34O02),(08V01),(32H10),-77-B-11-REPLACE TOE GUARD TO | Jan 26, 2012 | STIPULATION/IN-VIO | — |
| 950651 | Dec 6, 2011 | (77B11),(80B14),(70O02),(34E10),(34O02),(42G11),(59Y02),(32H10),77-B-1 | Jan 26, 2012 | STIPULATION/IN-VIO | — |
| 891004 | May 27, 2011 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT | Sep 29, 2011 | IN VIOLATION | — |
| 925096 | Dec 17, 2010 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT. | May 19, 2011 | IN VIOLATION | — |
| 950624 | Nov 22, 2010 | 37H11,10H07,67L10,14L07,521B2,55B12,39Y02. 32H- TOP & BOTTOM CAR GUIDE | Jan 13, 2011 | IN VIOLATION | — |
| 925091 | Sep 17, 2010 | FAILURE TO FILE AN AMENDED 6 ROUND REPORT ACCEPTABLE TO THIS DEPT INDI | Feb 24, 2011 | IN VIOLATION | — |
| 351741 | Apr 7, 2010 | 57X10 10H11 56Y13 56Y10 67X-REPAIR PLANE SYSTEM IN CAR 56Y-REPAIR & SE | May 27, 2010 | DEFAULT | — |
| 870315 | Apr 7, 2010 | 67X10 10H11 56Y13 56Y10 59Y02 67X-REPAIR PHONE SYSTEM IN CAR 56Y-REPAI | May 27, 2010 | DEFAULT | — |
| 925054 | Jan 23, 2009 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLI | Jul 30, 2009 | DEFAULT | — |
| 741841 | Jan 20, 2005 | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THE DEPT. | May 5, 2005 | IN VIOLATION | — |
| 741909 | Oct 6, 2004 | FAILURE TO FILE AN AMENDED 5TH ROUND REPORT ACCEPTABLE TO THIS DEPT. I | Mar 10, 2005 | IN VIOLATION | — |
| 741804 | Apr 16, 2004 | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPAR | Jun 24, 2004 | IN VIOLATION | — |
| 869826 | Jan 6, 2004 | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPAR | Mar 25, 2004 | IN VIOLATION | — |
| 820299 | Nov 6, 2003 | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPART | Jan 29, 2004 | WRITTEN OFF | — |
| 373592 | Jun 21, 2002 | 50B07/35D07/46B13/09M11/03I11/74R09/50-RETURN MACH LIMITS TO PEN MIN F | Aug 8, 2002 | IN VIOLATION | — |
| 373590 | Jun 21, 2002 | 33D09/03B07/50E11/29B07/46B13/37B0740E11/18L11/52L12/40L07/50B07/33-RE | Aug 8, 2002 | IN VIOLATION | — |
| 1387182 | Aug 15, 2001 | 73##. 73-FILE FOR REMOVAL OF THIS DEVICE. THIS DEVICE WAS IMPROPERLY R | Jan 17, 2002 | IN VIOLATION | — |
| 1135867 | Aug 14, 2001 | 33P17-75B05-22D06-46B13-49B13-11M10. 33-PROVIDE SAFE CONVENIENT ACCESS | Jan 17, 2002 | IN VIOLATION | — |
| 1135781 | Aug 14, 2001 | 75B05-28H12-03E06-15B11-46B13-49B13. 75-PERFORM REQ 5 YEAR TESTS 28-EL | Jan 17, 2002 | IN VIOLATION | — |
| 414297 | Feb 10, 1995 | 18L,73M.73M-OPERATING AN EQUIPMENT USE PERMIT EA 614/95 REMEDY:OBTAIN | Mar 30, 1995 | WRITTEN OFF | — |
| 121457 | Oct 17, 1994 | 3M,13M,31R,29H,47L,49R,50Y,54M,55M,73#,73M | Nov 17, 1994 | WRITTEN OFF | — |
| 72170 | Oct 17, 1994 | 3M,13M,18L,28L,29L,30M,33S,47L,49L,50Y,50Y,55M,73M,3M-CAPACITY PLATE 1 | Nov 17, 1994 | IN VIOLATION | — |
| 337823 | Dec 15, 1993 | 74P. REFUSED OF ACCESS. REMEDY:PROVIDE ACCESS SO THAT A FULL INSPECTIO | Feb 17, 1994 | WRITTEN OFF | — |
| 413247 | Dec 15, 1993 | 73M, OPERATION OF AN ELEVATOR WITHOUT AN EQUIPMENT USE PERMIT. REMEDY: | Jan 27, 1994 | WRITTEN OFF | — |
| 116937 | Dec 15, 1993 | 73X,74P. 73X RESTORE TO SERVICE. 74P REFUSAL OF ACCESS. REMEDY: | Jan 27, 1994 | WRITTEN OFF | — |
| 113035 | Mar 23, 1993 | 73X.73X-RESTORE TO SERVICE,SO THAT A FULL INSPECTION CAN BE MADE BY | Jul 22, 1993 | WRITTEN OFF | — |
| 112971 | Mar 23, 1993 | 73X.73X-RESTORE TO SERVICE,SO THAT A FULL INSPECTION CAN BE MADE BY | Jul 22, 1993 | WRITTEN OFF | — |
| 106110 | Mar 2, 1992 | 57#; 57. REMOVE HYDRULOC OIL. | Apr 30, 1992 | WRITTEN OFF | — |
| 106120 | Mar 2, 1992 | 46T;14M;40T; | Apr 30, 1992 | WRITTEN OFF | — |