OpenViolations
/

1181 Amsterdam Avenue

ManhattanBIN 1059499
HPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
0
Immediately hazardous
Open Class B
8
Hazardous
Open Class A
0
Non-hazardous
Fines due
$0.00
Balance on OATH/ECB summonses
Permits on file
30
DOB permit records
Last activity
Dec 4, 2025
Bedbugs record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

B
Health score · Jul 29, 2026
Scored from all 96 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 0
Open Class B violations
Hazardous
This building 8
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $0
Bedbug filings with infestations
Annual LL69 filings on record
This building 1
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 96 records on file.

Download this timeline (CSV) →
Dec 4, 2025
Dec 18, 2024
Jul 3, 2023
Feb 9, 2022
Jun 30, 2021
Jun 30, 2021
Jun 30, 2021
Jun 23, 2021
Jun 23, 2021
Jun 23, 2021
Jun 15, 2021
Feb 13, 2020
Oct 15, 2019
Aug 29, 2019
Aug 29, 2019
Aug 29, 2019
Aug 29, 2019
Aug 2, 2019
Jun 19, 2019
May 6, 2019
May 2, 2019
Apr 30, 2019
May 21, 2018
Feb 23, 2016
Aug 18, 2015
Aug 17, 2015
May 13, 2015
Mar 10, 2015
Mar 10, 2015
Dec 19, 2014

OATH / ECB summonses & fines

No balance is recorded as due across the 14 summonses below, out of $20,737.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 1181 Amsterdam Avenue
1051509Jun 30, 2021FLUE PIPE NOT SUPPORTED-PIPE AT BACK OF BOILER NOT CAPPED-NO SPILL SWINov 4, 2021ADMIT/IN-VIO
1445199Jun 23, 2021FOUND AO SMITH MODEL #BC670-834, BOILER NOT REGISTERED ON DOB RECORDS,Aug 12, 2021IN VIOLATION
1445211Jun 23, 2021FOUND TO HAVE CORRODED RETURN LINE AT BOTTOM OF BOILER, FLUE PIPE NOT Aug 12, 2021IN VIOLATION
1542648Feb 13, 2020FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EMay 6, 2021IN VIOLATION
613589Aug 29, 2019AT TIME OF INSPECTION AS I ENTERED APT 4E I NOTICED THAT ALL OF THE DROct 17, 2019IN VIOLATION
1346823May 21, 20186A,50,50A. 50-BOILER FLUE NOT WELDED AT SEAMS; 50A-GAS PILOT REGULATOJul 5, 2018STIPULATION/IN-VIO
65473Jul 13, 2010WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVApr 28, 2011IN VIOLATION
65650Jul 13, 2010SEC. 3314.4.3. FAILURE TO PROVIDE SUPPORTED SCAFFOLD DAILY INSPECTION Apr 28, 2011IN VIOLATION
1119174Apr 17, 2010OPERATION OF PLACE OF ASSEMBLY W/O A CURRENT CERTIFICATE OF OPERATION Jun 10, 2010DEFAULT
787346Apr 17, 2010APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABLE FOR INSP NOTED NO P/A PJun 10, 2010DEFAULT
681128Sep 12, 200751BB12/66O2/38O2/71M7/71Q7/.71M-LIGHT UNDER CAR,PROVIDE PULL STRING & Nov 8, 2007DEFAULT
749379Oct 2, 200135P07-33P07Nov 15, 2001STIPULATION/IN-VIO
377371May 15, 200175U05,46H13,49H13,15L01,21M12. 15L01-5TH FLR.DOOR HARD TO OPEN.21M12-RJul 5, 2001STIPULATION/IN-VIO
639248Jan 9, 199873O,22M, 22-TOP EMER. HATCH MUST BE SEALED SO IT CANT BE OPEN.May 21, 1998DEFAULT