| 1791577 | Jul 15, 2026 | VF.. R T S.. ELEVATOR IN BUILDING OUT OF SERVICE , UPON INSPECTION THE | Sep 24, 2026 | PENDING | $1,250.00 |
| 1830603 | Jun 30, 2026 | CLASS1 ITEM: RTS FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER | Sep 3, 2026 | PENDING | $1,250.00 |
| 418527 | Apr 20, 2026 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B AND 9B REPORT INDICATING C | Jul 16, 2026 | DEFAULT | $3,155.00 |
| 1784642 | Sep 9, 2024 | FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES.NOTES;LARGE VERT | Jan 16, 2025 | DEFAULT | $6,250.00 |
| 1731671 | Jan 16, 2024 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B AND 9B REPORT INDICATING C | Apr 11, 2024 | DEFAULT | $6,250.00 |
| 1834332 | Dec 2, 2021 | FAILURE TO POST EXTERIOR BUILDING WALLS CONDITION CERTIFICATE AS REQUI | Oct 6, 2022 | IN VIOLATION | — |
| 1834331 | Dec 2, 2021 | FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES.AS NOTED:AT TIME | Oct 6, 2022 | IN VIOLATION | $211.00 |
| 1588261 | Jun 1, 2021 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL E | Oct 7, 2021 | DEFAULT | — |
| 1587940 | Oct 15, 2018 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION D | Apr 4, 2019 | IN VIOLATION | — |
| 1535736 | Aug 14, 2018 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. SOUTH | Oct 4, 2018 | Resolved | — |
| 1566439 | Jul 17, 2018 | 2X10,40P16,70O2. (2X)OUTSIDE COMM,INOPERATIVE,REPAIR. (40P)MACHINE ROO | Oct 25, 2018 | IN VIOLATION | — |
| 889586 | Jan 30, 2017 | 97X17 THE ONLY ELEVATOR IN BLDG OUT OF SERVICE.UPON INSPECTION, THE DE | May 4, 2017 | IN VIOLATION | — |
| 851141 | Jan 25, 2011 | FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE | Jul 14, 2011 | IN VIOLATION | — |
| 608687 | Jun 4, 2010 | FAILED TO FILE AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLIANC | Feb 3, 2011 | IN VIOLATION | — |
| 1154548 | Jan 29, 2010 | 12Q3.39O2.39X10.60Q3.71Q3.77Q3.12Q3 INSTALL GUARD FOR CAR LIGHTING DRO | Mar 25, 2010 | STIPULATION/IN-VIO | — |
| 606974 | Dec 26, 2008 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIAN | Jun 25, 2009 | IN VIOLATION | — |
| 533466 | Dec 10, 2008 | 12Q0367M0710H1117H1108V0103D0639X1039O0232H1070O0271Q0305X10100B1060Q0 | May 21, 2009 | IN VIOLATION | — |
| 360687 | Jul 19, 2005 | 16##/39P07/84Y13/66O02/83##/33I10. 16-PROVIDE SERVICE TO THE 6TH AND 7 | Dec 1, 2006 | IN VIOLATION | — |
| 315190 | Aug 20, 1998 | 20L,07B,21L,13M, 20-HALL BUTTONS NOT LIGHTING. 07-LIGHT RAY NOT WORK-- | Oct 8, 1998 | STIPULATION/IN-VIO | — |
| 189207 | Apr 9, 1998 | FAILURE TO SUBMIT A 4TH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF | Jun 4, 1998 | IN VIOLATION | — |
| 1467307 | Dec 30, 1991 | FAILURE TO PROVIDE CONTRACTOR SIGN: AT TIME OF INSPECTION NO CONTRACTO | Aug 21, 1992 | WRITTEN OFF | — |