| 243553 | Apr 10, 2017 | 3310.10ORIENTATION NOTE:AT THE TIME OF MY INSPECTION OF A 17 STORY BIL | May 25, 2017 | IN VIOLATION | — |
| 243539 | Apr 10, 2017 | FAILURE TO INSTITUTE AND MAINTAIN SAFETY MEASURES AND TEMPORARY CONSTR | May 25, 2017 | IN VIOLATION | — |
| 890508 | Apr 10, 2017 | 3303.12 ELEVATORS END HOISTS DURING CONSTRUCTION.NOTE:AT THE TIME OF M | May 25, 2017 | IN VIOLATION | — |
| 1213188 | Mar 28, 2017 | BC3301.3/SITE SAFETY MANAGER;AT THE TIME OF INSPECTION OF A 17 STORY B | May 18, 2017 | IN VIOLATION | — |
| 883958 | Mar 28, 2017 | DESIGN: CONTRARY TO SUSPENDED SCAFFOLD DESIGN. NOTED: ACTIVE 17 STORY | May 18, 2017 | IN VIOLATION | — |
| 1205693 | Mar 28, 2017 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV | May 18, 2017 | IN VIOLATION | — |
| 1205702 | Mar 28, 2017 | BC3301.2 SAFETY MEASURES AND STANDARDS NO CAZ NOTED: ACTIVE 17 STORY | May 18, 2017 | IN VIOLATION | — |
| 266888 | May 9, 2016 | POSTING OF UNLAWFUL SIGNS, INFORMATION, PICTORIAL REPRESENTATION, BUSI | Jun 23, 2016 | IN VIOLATION | — |
| 1163180 | May 9, 2016 | SEC: 3307.6.2. AREA TO BE PROTECTED: OVERHEAD PROTECTION. NOTE: @ TIME | Jun 23, 2016 | IN VIOLATION | — |
| 266653 | May 9, 2016 | SEC: 28-110.1. OSHA 10- NOT AVAILABLE. @ THE TIME OF INSP I OBSERVED A | Jun 23, 2016 | STIPULATION/IN-VIO | — |
| 266773 | May 9, 2016 | SEC: 3308.3.VERTICAL SAFETY NETTING NOT PER CODE. NOTE: ACTIVE 17 STO | Jun 23, 2016 | STIPULATION/IN-VIO | — |
| 1027517 | Sep 8, 2015 | SEC. 3308.2. HORIZONTAL SAFETY NETTING INADEQUATE TIME OF INSPECTION T | Oct 29, 2015 | IN VIOLATION | — |
| 1027489 | Sep 8, 2015 | FAILURE TO PROVIDE GUARDRAIL.AT TIME OF INSPECTION NOTED THAT THERE WA | Oct 29, 2015 | IN VIOLATION | — |
| 1027488 | Sep 8, 2015 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING AT TIME OF INSPECTON NOTE TH | Oct 29, 2015 | IN VIOLATION | — |
| 1027487 | Sep 8, 2015 | FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONSTRUCTION OPERAT | Oct 29, 2015 | IN VIOLATION | — |
| 1021811 | May 13, 2015 | 3303.4.3 INSUFFICIENT CONTAINERS AVAILABLE AT ACTIVE JOBSITE WHERE A L | Jul 2, 2015 | IN VIOLATION | — |
| 1021815 | May 13, 2015 | FAILURE TO MAINTAIN ADEQUATE HOUSE KEEPING PER SECTION REQUIREMENT.NOT | Jul 2, 2015 | IN VIOLATION | — |
| 768870 | May 13, 2015 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS OR APPROVED A | Jul 2, 2015 | IN VIOLATION | — |
| 216454 | Apr 14, 2015 | BC1905.6.2.1 FAILURE TO PROVIDE THE MINIMUM FREQUENCY SAMPLES FOR STRE | Jun 18, 2015 | IN VIOLATION | — |
| 216451 | Apr 14, 2015 | BC 3301.7 FAILURE TO PROVIDE P.E APPROVED DESIGN DRAWING.AS NOTED:@TIM | Jun 4, 2015 | DEFAULT | — |
| 538317 | Apr 27, 2009 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSP | Dec 16, 2010 | IN VIOLATION | — |
| 538312 | Apr 27, 2009 | INADEQUATE SAFETY MEASURE:OPER'NOF HOISTING EQUIPMENT IN UNSAFE MANNE | Dec 17, 2010 | IN VIOLATION | — |
| 1085286 | May 23, 2001 | FAILURE TO PROVIDE APPROVED SET OF PLANS AT TIME OF INSPECTION.NOTED:W | Apr 25, 2002 | WRITTEN OFF | — |
| 433905 | Jul 11, 2000 | SUPERVISION AND USE OF RIGGING EQUIPMENT WITHOUT A SPECIAL RIGGERS LIC | Apr 18, 2002 | IN VIOLATION | — |
| 433846 | Jul 11, 2000 | 3 WORKERS ON A TWO POINT SUSPENDED SCAFFOLD 2 (TWO)PT. SUSPENDED SCAFF | Dec 29, 2000 | WRITTEN OFF | — |