| 1733830 | Feb 22, 2025 | 28-323.1. FAILURE TO MAINTAIN PARKING STRUCTURE INSAFE CONDITION. NOTE | Oct 16, 2025 | IN VIOLATION | — |
| 391115 | Jun 19, 2020 | VIOLATION OF DISCRETIONARY ZONING CONDITION ON PRIVATELY OWNED PUBLIC | Mar 10, 2022 | IN VIOLATION | — |
| 1184831 | Apr 19, 2017 | 05A10 DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND RENDER | Jun 8, 2017 | IN VIOLATION | — |
| 879583 | Jan 15, 2013 | 1RCNY 9-01. RIGGER FAILED TO DESIGNATE A FOREMAN - NOTED: NO RIGGING | Mar 7, 2013 | IN VIOLATION | — |
| 879589 | Jan 15, 2013 | LICENSED RIGGER FAILED TO ENSURE A SCAFFOLD WORKER MET MINIMUM REQUIRE | Mar 7, 2013 | IN VIOLATION | — |
| 912736 | Jan 15, 2013 | PARTIAL *SWO* FAILURE TO HAVE SITE SAFETY MANAGER OR COORDINATOR PRESE | Apr 18, 2013 | IN VIOLATION | — |
| 978039 | Jan 3, 2013 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST OFF "C" HOOKS IN | Feb 21, 2013 | ADMIT/IN-VIO | — |
| 789870 | Dec 16, 2011 | NOTED AT EAST #4 EXP AT 22 FL AT CONCRETE 22FL SUBLEVEL EYEBROW AT SOU | Feb 23, 2012 | IN VIOLATION | — |
| 845682 | Dec 2, 2011 | FAILED TO NOTIFY DEPARTMENT/OBTAIN PERMIT PRIOR TO USE/INST OFF "C" HO | Jan 19, 2012 | IN VIOLATION | — |
| 455099 | Dec 2, 2011 | INADEQUATE SAFETY MEASURES OPERATION OF HOISTING EQUIPMENT IN UNSAFE M | Jan 19, 2012 | IN VIOLATION | — |
| 1013216 | Dec 1, 2011 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.CELLAR STONE RUBBLE | Jan 19, 2012 | IN VIOLATION | — |
| 533035 | Dec 1, 2011 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.EXIT DOOR HAS HOLE I | Jan 19, 2012 | IN VIOLATION | — |
| 525461 | Dec 17, 2009 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTE: AT CELLAR LEV | Feb 11, 2010 | STIPULATION/IN-VIO | — |
| 803533 | Dec 17, 2009 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTE: AT CELLAR LEVEL | Feb 11, 2010 | IN VIOLATION | — |
| 856707 | Dec 17, 2009 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. USE OF PROHIBITED D | Feb 11, 2010 | IN VIOLATION | — |
| 266780 | Oct 19, 2007 | EXIT LIGHTING DEFECTIVE FAILS TO MEET BLDG CODE STANDARDS.DEFECT NOTED | Jan 24, 2008 | CURED/IN-VIO | — |
| 736309 | May 5, 2004 | 40/50A/50B FULTON V.T BOILER 20HP NB 72355 GAS 1995 50A-BOLOW DOWN LIN | Apr 21, 2005 | IN VIOLATION | — |
| 405631 | Feb 24, 2004 | 14M07/17L01/30L06/51L14/64X10 17L-TOO 30L-UP MUST BE PINNED 51L-AFTER | Apr 15, 2004 | IN VIOLATION | — |
| 405638 | Feb 24, 2004 | 14M7/17L01/28L10/55Y13 17L-TOO LIGHT 28L-DOORS STAY OPEN WHERE CAR IS | Apr 15, 2004 | IN VIOLATION | — |
| 474056 | Mar 25, 2003 | (1) FAILURE TO OBTAIN A PERMIT FOR TEMPORARY CONSTRUCTION. SIDEWALK SH | Dec 23, 2004 | IN VIOLATION | — |
| 460892 | Mar 25, 2003 | (1) SIDEWALK SHED DOES NOT MEET BUILDING CODE SPECIFICATIONS. DEFECTS | Jan 15, 2004 | IN VIOLATION | — |
| 460676 | Feb 12, 2003 | FAILURE TO OBTAIN A PERMIT (EXPIRED NOTED SIDEWALK SHED ERECTED UNDER | Jan 15, 2004 | IN VIOLATION | — |
| 736234 | Oct 31, 2001 | 16-49-SUBMIT PROOF OF REGISTRATION(APPROVED 900-A) FOR THIS HP BOILER | Dec 20, 2001 | STIPULATION/IN-VIO | — |
| 404788 | Aug 10, 2001 | 95H12/5J11/11X11/22O2/23U16/46B15/47B15/60U5/75U5 50J11-TOO MUCH GAP T | Nov 29, 2001 | IN VIOLATION | — |
| 404762 | Aug 10, 2001 | 9H12/15I11/16H12/22O2/23U16/30O2/31Q3/57O2/60U5/60M7/60L11/75U5 15I11- | Nov 29, 2001 | IN VIOLATION | — |
| 404707 | Aug 10, 2001 | 5J11/9H12/11X11/16H12/22O2/23U16/30O2/46B15/55X11/56Q3/75U5/57O2/5J11 | Nov 29, 2001 | IN VIOLATION | — |
| 403178 | Apr 23, 1996 | 29#,57O,. (29) PROVIDE RUN-BY | Jun 13, 1996 | STIPULATION/IN-VIO | — |