Open Class C
2
Immediately hazardous
Open Class B
20
Hazardous
Open Class A
0
Non-hazardous
Fines due
$25,625.00
Balance on OATH/ECB summonses
Permits on file
143
DOB permit records
Last activity
Jun 22, 2026
DOB record
Building health score
A composite of public indicators. Every input is a public record. See the full methodology.
D
Health score · Jul 29, 2026
Scored from the 300 most recent of 749 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 2
Open Class B violations
Hazardous
This building 20
Heat & hot water records
Violations and complaints, last 24 months
This building 1
Unpaid penalties
OATH/ECB summonses with balance due
This building $25,625
Bedbug filings with infestations
Annual LL69 filings on record
This building 1
Tenant litigation
Open HP actions in Housing Court
This building 2
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No
Unified timeline
Records from every agency, interleaved. Showing the 300 most recent of 749 records on file; the CSV below has the full history.
Jun 22, 2026
May 15, 2026
Apr 21, 2026
Apr 21, 2026
Apr 20, 2026
Apr 17, 2026
Apr 13, 2026
Apr 13, 2026
Apr 8, 2026
Mar 21, 2026
Mar 6, 2026
Mar 4, 2026
Feb 16, 2026
Jan 29, 2026
Jan 8, 2026
Dec 24, 2025
Nov 8, 2025
Oct 30, 2025
Oct 29, 2025
Oct 28, 2025
Oct 28, 2025
Oct 23, 2025
Oct 17, 2025
Sep 18, 2025
Sep 9, 2025
Dec 16, 2024
Dec 16, 2024
Dec 16, 2024
Nov 26, 2024
Nov 14, 2024
OATH / ECB summonses & fines
$25,625.00 is recorded as due across the 80 summonses below, out of $117,880.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.
| 1795720 | Apr 20, 2026 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTI | Sep 10, 2026 | PENDING | $3,125.00 |
| 1771480 | Apr 13, 2026 | 2/X/10 OUT SIDE COMM INOPERATIVE REPAIR, 5/L/10 CLASS 1, CAR CEASE USE | Jun 18, 2026 | IN VIOLATION | $1,250.00 |
| 1378856 | Jan 8, 2026 | VF... CEASE USED... DOOR RESTRICTOR NOT WORKING REPAIR AND ARRANGE INS | Sep 15, 2026 | Resolved | $1,250.00 |
| 1688708 | Oct 29, 2025 | VF RTS ELEVATOR IS OUT OF SERVICE UPON INSPECTION THE DEVICE IS FOUND | Aug 6, 2026 | Resolved | $1,250.00 |
| 1804364 | Nov 14, 2024 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AS NOTE | Jan 23, 2025 | DEFAULT | $6,250.00 |
| 1403985 | Sep 25, 2024 | FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES.NOTE:CRACK BRICK | Aug 14, 2025 | DEFAULT | $12,500.00 |
| 1776771 | Jul 17, 2024 | BRAKE SWITCHES ARE DISABLED/BYPASSED. : RESTORE TO SERVICE IMMEDIATELY | Sep 26, 2024 | ADMIT/IN-VIO | — |
| 1349780 | Mar 20, 2024 | CLASS 1: UPON INSPECTION FOUND DEVICE TO BE OUT OF SERVICE. THIS PRESE | May 30, 2024 | ADMIT/IN-VIO | — |
| 1534680 | Jan 16, 2024 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9A REPORT INDICATING CORRECTI | Apr 18, 2024 | DEFAULT | — |
| 1347717 | Feb 4, 2019 | CU5A10,CU59I10. 5A10-CAR DOOR RESTRICTOR AL() REPAIR; CAR DOOR RESTRI | Mar 29, 2019 | IN VIOLATION | — |
| 1449979 | May 18, 2018 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION | Nov 15, 2018 | IN VIOLATION | — |
| 1116546 | Oct 25, 2016 | 05L01 RSTOR NOT WORKING MISSING PART. | Feb 16, 2017 | IN VIOLATION | — |
| 1116637 | Oct 25, 2016 | 05L01, 05/L/01-DOOR RESTOR NOT WORKING MISSING PARTS. | Feb 16, 2017 | IN VIOLATION | — |
| 1116631 | Oct 25, 2016 | 05L01,52B07. 05L01-RESTOR NOT WORKING MISSING PARS; 52B07- PROVIDE PR | Feb 16, 2017 | IN VIOLATION | — |
| 1000188 | Aug 19, 2014 | 18B-6.16J11,05J01,71L11,42M11,97L10. 18B06-HOISTWAY DOOR L LEVEL HANGE | Oct 9, 2014 | IN VIOLATION | — |
| 839221 | Apr 23, 2014 | 02L10/ 02-L-10- ALARM BELL NOT WORKING | Jun 12, 2014 | STIPULATION/IN-VIO | — |
| 1166713 | Dec 17, 2013 | 99B05 - PERFORM FILE TEST CAT 1 TAGS ARE NOT CURRENT LAST CAA 1 TAG 11 | Feb 6, 2014 | IN VIOLATION | — |
| 1166721 | Dec 17, 2013 | 99B05:PERFORM FILE TEST.CAT 1 TAG NOT CURRENT LAST CAT 1 TAG 11/30/12. | Feb 6, 2014 | IN VIOLATION | — |
| 1166715 | Dec 17, 2013 | 99B05,56V10. 99B05-REFORM FILE TEST CAT 1 TEST RAGS NOT CURRENT; 56Y10 | Feb 6, 2014 | IN VIOLATION | — |
| 1155107 | Nov 29, 2013 | B251:97X10,56Y13.97X10:ENTIRE DEVICE INOPERATIVE;REPAIR AND CALL DOB E | Jan 16, 2014 | DEFAULT | — |
| 1049346 | Nov 6, 2013 | INADEQUATE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN UNSAFE | Dec 26, 2013 | IN VIOLATION | — |
| 1049345 | Nov 6, 2013 | SEC. 1408.1 FAILURE TO HAVE A FIRE SAFETY MANAGER AS REQUIRED. NOTED: | Dec 26, 2013 | IN VIOLATION | — |
| 1049347 | Nov 6, 2013 | LICENSED RIGGER RAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIREME | Dec 26, 2013 | IN VIOLATION | — |
| 1028298 | Aug 6, 2013 | USE OF SUPPORTED SCAFFOLD W/O SCAFFOLD USER CERTIFICATE. TWO WORKERS | Sep 26, 2013 | IN VIOLATION | — |
| 667447 | Apr 9, 2013 | NO DAILY LOG FOR SUPPORTED SCAFFOLD. *STOP WORK ORDER* - MEN ON SUPPOR | May 30, 2013 | IN VIOLATION | — |
| 1000049 | Apr 9, 2013 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROV | May 30, 2013 | STIPULATION/IN-VIO | — |
| 1027911 | Mar 28, 2013 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST OFF C-HOOKS IN C | May 16, 2013 | IN VIOLATION | — |
| 1028331 | Mar 22, 2013 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A SWO. AT THE TIME OF MY | May 9, 2013 | IN VIOLATION | — |
| 1028332 | Mar 22, 2013 | SEC. BC 1001.3. FAILURE TO MAINTAIN EGRESS CLEAR AND UNOBSTRUCTED. AT | May 9, 2013 | IN VIOLATION | — |
| 362817 | Mar 22, 2013 | 50A-NO ELECTRICAL PERMIT FILED WITH DOB FOR THE HOOK UP TO MOBILE BOIL | Jun 13, 2013 | IN VIOLATION | — |
| 362924 | Mar 22, 2013 | B254,32A,21A,50A. 50A-OIL FILL LINE CAP MISSING OUTSIDE OF MOBILE | Jun 13, 2013 | IN VIOLATION | — |
| 1028192 | Mar 5, 2013 | WORK DOES NOT CONFORM TO APPROVED SITE SAFETY PLAN. AT THE TIME OF MY | Apr 25, 2013 | IN VIOLATION | — |
| 1028191 | Mar 5, 2013 | I RESPONDED TO COMPLAINT 1344275 AS PER CONST,SITE 4-MAN WORKERS WERE | Apr 25, 2013 | IN VIOLATION | — |
| 1028193 | Mar 5, 2013 | BC3314.5.5 FAILURE TO TIE DOWN PLATFORM ON SUPPORTED PIPE SCAFFOLD.@TI | Apr 25, 2013 | IN VIOLATION | — |
| 724603 | Oct 24, 2012 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. - SHED DOES NOT EXTEN | Dec 13, 2012 | IN VIOLATION | — |
| 704454 | Nov 22, 2011 | 97,X,10 RESTORE TO SERVICE FOR PROPER D.O.B INSPECTIONS. | Jan 12, 2012 | STIPULATION/IN-VIO | — |
| 968182 | Oct 5, 2011 | 99BB05,99BB05,40M07,68B08,05M08,17H11. 98&99- EXPIRED (AT) 1& (AT) 5 | Dec 1, 2011 | STIPULATION/IN-VIO | — |
| 892810 | Aug 26, 2011 | FAILURE TO POST WORK PERMIT AT PREMISES UPON INSPEC.CONTRACTOR FAILED | Oct 13, 2011 | DEFAULT | — |
| 806964 | Jul 5, 2011 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO OR BLDG DEPT RECORDS.DE | Nov 17, 2011 | IN VIOLATION | — |
| 906543 | Sep 28, 2010 | SEC BC 1003.2 & 27-369(B) MISC VIOL: FAIL TO COMPLY W.CEILING HEIGHT. | Jan 13, 2011 | IN VIOLATION | — |
| 353455 | Sep 23, 2010 | FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. USE OF PROHIBITED HARD | Jan 13, 2011 | IN VIOLATION | — |
| 1065211 | Apr 2, 2010 | 24B10.45H10.52H11.56Y2.73O2.74O2.75O2.77O2.78O2.24 HALL STATION AND CA | May 27, 2010 | STIPULATION/IN-VIO | — |
| 638301 | Apr 2, 2010 | 24B10.45H10.52H11.56Y2.73O2.74O2.75O2.77O2.78O2.24 HALL STATION NOT WO | May 27, 2010 | STIPULATION/IN-VIO | — |
| 550748 | Mar 8, 2010 | 24I10. 24- REPAIR DEFECTIVE HALL BUTTON/STATION IN DILATORS. FLOORS NU | May 6, 2010 | STIPULATION/IN-VIO | — |
| 890883 | Jan 27, 2010 | FAILURE TO FILE AN ARCHITECT ENGINEER REPORT CERTIFYING EXIT DIRECTION | Sep 16, 2010 | IN VIOLATION | — |
| 160157 | Oct 28, 2009 | FAILURE TO MAINTAIN BLDG IN A CODE-COMPLIANT MANNER RE: INSTALLATION/M | Dec 17, 2009 | STIPULATION/IN-VIO | — |
| 912803 | Oct 8, 2009 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO FILE A CERTIFICATE O | Oct 14, 2010 | IN VIOLATION | — |
| 1061667 | Oct 8, 2009 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. IMPROPER EXIT/ | Oct 14, 2010 | IN VIOLATION | — |
| 851624 | Aug 26, 2009 | FAILURE TO COMPLY W/ THE COMMS ORDER TO FILE A CERT OF CORRECTION W/ T | Oct 14, 2010 | IN VIOLATION | — |
| 773342 | Mar 26, 2009 | SEC.BC1014.2.1. FAILURE TO COMPLY W/TWO EXIT ACCESS DOORWAY REQUIREMEN | May 14, 2009 | IN VIOLATION | — |
| 647561 | Mar 12, 2009 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTE EXIT STAIRWAY AT | Apr 30, 2009 | IN VIOLATION | — |
| 778573 | Mar 12, 2009 | WORK W/O A PERMIT WORK NOTED THE SEALING OF EXISTING OPENINGS LEADINGS | Apr 30, 2009 | IN VIOLATION | — |
| 578162 | Dec 1, 2008 | WORK W/O A PERMIT WORK NOTED REPLACEMENT OF EXISTING CELLAR STAIR WITH | Jul 9, 2009 | IN VIOLATION | — |
| 771427 | Apr 3, 2008 | FAILURE TO PROVIDE AT LEAST 2 REMOTE EXISTS FROM EACH OTHER. NOTE:AT 1 | May 29, 2008 | IN VIOLATION | — |
| 909172 | Mar 12, 2008 | 06L10.10H11.17H11.55Y13.85BB05.51H11 06L10 FIX SLOW SPEED DOOR 10H11 R | May 8, 2008 | STIPULATION/IN-VIO | — |
| 909169 | Mar 12, 2008 | 55Y13.51H11.10H11.85BB05.17H11. 55Y13 SEAL LOCKS ON MACHINE 51H11.HOIS | May 8, 2008 | STIPULATION/IN-VIO | — |
| 729351 | Aug 20, 2007 | CU:36H10/.36-OVERHEAD SHEAVE IS BAD MAKING NOISE BEFORE RETURNING BACK | Oct 11, 2007 | IN VIOLATION | — |
| 578519 | Mar 17, 2007 | 83P16/.83-P-16-NO KEYS ON SITE FOR MOTOR ROOM.COULDN'T DO ROUTINE INSP | May 10, 2007 | IN VIOLATION | — |
| 578523 | Mar 17, 2007 | 83P16/.83-P-16-NO KEYS ON SITE FOR MOTOR ROOM.COULDN'T DO ROUTINE INSP | May 10, 2007 | IN VIOLATION | — |
| 578522 | Mar 17, 2007 | 83P16/.83-P-16-NO KEYS ON SITE FOR MOTOR ROOM.COULDN'T DO ROUTINE INSP | May 10, 2007 | IN VIOLATION | — |
| 414933 | Jun 17, 2003 | 73B07 34D07 34Q07 16M07 73-LOOP COMP CHAINS OVER 5 HOOKS AS REQUIRED 3 | Aug 7, 2003 | IN VIOLATION | — |
| 393011 | Jun 17, 2003 | 34D07 34Q07 16M07 34D-Q-COVER AND SECURE LOW VOLTAGE SECURITY WIRING A | Aug 7, 2003 | IN VIOLATION | — |
| 402145 | Apr 16, 2002 | 40U5, 52B7, 40M14, 50U16, 73X11. 40-TWO EAR TEST 52- COTTER PINS 50- C | Jul 18, 2002 | IN VIOLATION | — |
| 391571 | Apr 16, 2002 | 40U5/11IQ/40M14/33W6/50U16/54I11. 4O TWO YEAR TEST. 50 CITY ID. | Jul 18, 2002 | IN VIOLATION | — |
| 458977 | Apr 16, 2002 | 40U5, 52B7, 47#15, 31Q3, 5E11, 28H10, 31Q3, 11Q3, 74L11, 22#7, 33W6, 3 | Jul 18, 2002 | IN VIOLATION | — |
| 363288 | Mar 19, 2002 | 73X11/ RESTORE TO PROPER WORKING ORDER CALL FOR REINSPECTION 1646 248 | May 9, 2002 | IN VIOLATION | — |
| 433630 | Sep 5, 2000 | 46#15 60I11 11Q3 22D6 11I11 5E1 3M7 40M12 33M12 33O2 50Y14 50#9 33X11 | Oct 26, 2000 | WRITTEN OFF | — |
| 292148 | Feb 1, 2000 | FAILURE TO PROTECT ROOF AND TENANT IN APT BELOW SAID ROOF DURING CONST | Mar 23, 2000 | WRITTEN OFF | — |
| 236857 | Feb 24, 1999 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO CORRECT THE VIOLATIO | Dec 23, 1999 | WRITTEN OFF | — |
| 237345 | Feb 24, 1999 | FAILURE TO COMPLY WITH THE COMMISSIONEERS ORDER TO CORRECT VIOLATION C | Apr 22, 1999 | WRITTEN OFF | — |
| 237290 | Feb 24, 1999 | FAILURE TO COMPLY WITH THE COMMISNONEERIS ORDER TO CORRECT THE VIOLATI | Apr 22, 1999 | WRITTEN OFF | — |
| 472527 | Feb 24, 1999 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO CORRECT THE VIOLATIO | Aug 26, 2004 | IN VIOLATION | — |
| 237028 | Feb 24, 1999 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO CORRECT THE VIOLATIO | May 13, 1999 | WRITTEN OFF | — |
| 228893 | Sep 9, 1998 | 50Y,44M,25Q.44 DUCT COVER MISSING GEN SET | Oct 28, 1998 | IN VIOLATION | — |
| 171571 | Sep 9, 1998 | 50Y,74M.74 CITY TAG ON MAIN MACHINE | Oct 28, 1998 | IN VIOLATION | — |
| 188203 | Sep 9, 1998 | 50X. | Oct 28, 1998 | IN VIOLATION | — |
| 593221 | Feb 18, 1997 | WORK WITHOUT A PERMIT WORK NOTED A KICTHCEN IS CONSTRUCTED IN THE LIVI | Jul 10, 1997 | WRITTEN OFF | — |
| 593219 | Feb 18, 1997 | B5C 27-749 OBSTRUCTION OF THE MECHENICAL VENTILATIOR IN THE BATH ROOM | Jul 10, 1997 | WRITTEN OFF | — |
| 4475 | Jul 24, 1996 | 50E, REMEDY:NOISE ON MACHINE HOIST MOTOR. | Sep 26, 1996 | STIPULATION/IN-VIO | — |
| 588914 | Dec 29, 1994 | PIPING AND/OR EQUIPTMENT INSTALLED IMPROPERLY. 2 KITCHEN SINKS | Mar 2, 1995 | WRITTEN OFF | — |